首页 > 最新文献

IEEE Transactions on Electrical Insulation最新文献

英文 中文
Detection and location of internal defects in the insulation of power transformers 电力变压器绝缘内部缺陷的检测与定位
Pub Date : 1993-12-01 DOI: 10.1109/14.249379
J. Fuhr, M. Haessig, P. Boss, D. Tschudi, R. King
With the development of fast, and low-cost analog-digital converters (ADCs) and new mathematical procedures for waveform description, e.g., time encoded signal processing and recognition (TESPAR), novel approaches to detect and locate internal defects in the insulation of power transformers become feasible if the following requirements are fulfilled: the equivalent circuit of the insulating system, suitable for the fast partial discharge (PD) signals with risetimes of approximately 10 ns, is known; the response of the insulating system to PD signals injected at least at three different sites of each winding (top, center, bottom) is calculated, or measured at the signal tap-off points (i.e., bushings); and the pattern matrix of all calculated or measured signals exists: e.g., encoded and signal processes with TESPAR as a reference. The above mentioned requirements are examined for quasi-simultaneous detection and location of internal defects in power transformers. The method is applied to PD measurements on power transformers. >
随着快速、低成本的模数转换器(adc)和用于波形描述的新数学程序的发展,如时间编码信号处理和识别(TESPAR),如果满足以下要求,检测和定位电力变压器绝缘内部缺陷的新方法变得可行:已知适用于上升时间约为10ns的快速局部放电(PD)信号的绝缘系统等效电路;在信号分接点(即套管)处计算或测量至少在每个绕组的三个不同位置(顶部、中心、底部)注入的绝缘系统对PD信号的响应;并且存在所有计算或测量信号的模式矩阵:例如,以TESPAR为参考的编码和信号处理。对电力变压器内部缺陷的准同时检测和定位,考察了上述要求。将该方法应用于电力变压器局部放电的测量。>
{"title":"Detection and location of internal defects in the insulation of power transformers","authors":"J. Fuhr, M. Haessig, P. Boss, D. Tschudi, R. King","doi":"10.1109/14.249379","DOIUrl":"https://doi.org/10.1109/14.249379","url":null,"abstract":"With the development of fast, and low-cost analog-digital converters (ADCs) and new mathematical procedures for waveform description, e.g., time encoded signal processing and recognition (TESPAR), novel approaches to detect and locate internal defects in the insulation of power transformers become feasible if the following requirements are fulfilled: the equivalent circuit of the insulating system, suitable for the fast partial discharge (PD) signals with risetimes of approximately 10 ns, is known; the response of the insulating system to PD signals injected at least at three different sites of each winding (top, center, bottom) is calculated, or measured at the signal tap-off points (i.e., bushings); and the pattern matrix of all calculated or measured signals exists: e.g., encoded and signal processes with TESPAR as a reference. The above mentioned requirements are examined for quasi-simultaneous detection and location of internal defects in power transformers. The method is applied to PD measurements on power transformers. >","PeriodicalId":13105,"journal":{"name":"IEEE Transactions on Electrical Insulation","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1993-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"73020129","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 76
The effect of the definition used in measuring partial discharge inception voltages 用于测量局部放电起始电压的定义的影响
Pub Date : 1993-12-01 DOI: 10.1109/14.249373
M. Pompili, C. Mazzetti, M. Libotte, E. Forster
At present, several definitions of partial discharge inception voltage (PDIV) have been advanced. To establish the value of each of these definitions, four practical electrical insulating fluids are selected, and their PDIV is determined according to three of these different specifications. The results suggest that the use of PDIV as a quality criterion generally is not warranted. The significance of these findings is discussed. >
目前,对局部放电起始电压(PDIV)有几种不同的定义。为了确定每个定义的值,选择了四种实用的电绝缘流体,并根据这些不同规格中的三种确定其PDIV。结果表明,使用PDIV作为质量标准通常是不合理的。讨论了这些发现的意义。>
{"title":"The effect of the definition used in measuring partial discharge inception voltages","authors":"M. Pompili, C. Mazzetti, M. Libotte, E. Forster","doi":"10.1109/14.249373","DOIUrl":"https://doi.org/10.1109/14.249373","url":null,"abstract":"At present, several definitions of partial discharge inception voltage (PDIV) have been advanced. To establish the value of each of these definitions, four practical electrical insulating fluids are selected, and their PDIV is determined according to three of these different specifications. The results suggest that the use of PDIV as a quality criterion generally is not warranted. The significance of these findings is discussed. >","PeriodicalId":13105,"journal":{"name":"IEEE Transactions on Electrical Insulation","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1993-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"72983848","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 35
PD pattern recognition with neural networks using the multilayer perceptron technique 基于多层感知器技术的神经网络PD模式识别
Pub Date : 1993-12-01 DOI: 10.1109/14.249382
A. Mazroua, M. Salama, R. Bartnikas
The partial discharge (PD) pattern recognition capability of a neural network, employing the multilayer perceptron technique with data input based on five discharge pulse form parameters, is examined. Simple discharge sources, consisting of artificially created cylindrical cavities with metallic and dielectric electrodes, are employed. The PD pattern discrimination capability is tested using cavities of equal depth but with different electrodes, and cavities of varying depths but with similar electrodes. Preliminary test results are positive. >
研究了基于5种放电脉冲形式参数输入的多层感知器神经网络的局部放电模式识别能力。采用了简单的放电源,由人工制造的带有金属和介电电极的圆柱形腔组成。采用等深但不同电极的空腔和不同深度但相似电极的空腔测试了PD模式识别能力。初步检测结果呈阳性。>
{"title":"PD pattern recognition with neural networks using the multilayer perceptron technique","authors":"A. Mazroua, M. Salama, R. Bartnikas","doi":"10.1109/14.249382","DOIUrl":"https://doi.org/10.1109/14.249382","url":null,"abstract":"The partial discharge (PD) pattern recognition capability of a neural network, employing the multilayer perceptron technique with data input based on five discharge pulse form parameters, is examined. Simple discharge sources, consisting of artificially created cylindrical cavities with metallic and dielectric electrodes, are employed. The PD pattern discrimination capability is tested using cavities of equal depth but with different electrodes, and cavities of varying depths but with similar electrodes. Preliminary test results are positive. >","PeriodicalId":13105,"journal":{"name":"IEEE Transactions on Electrical Insulation","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1993-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"83302501","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 97
Measuring the endurance of films in partial discharges 测量薄膜在局部放电时的耐久性
Pub Date : 1993-12-01 DOI: 10.1109/14.249378
R. Bozzo, L. Centurioni, F. Guastavino
A new test assembly for measuring the endurance of polymeric and ceramic films under the action of partial discharges (PDs) is presented. If experiments are performed under controlled ambient conditions (i.e., relative humidity), the test procedure gives times to breakdown which show low scatter. The effects of different test conditions on the times to breakdown and relevant data scatter are presented. The adoption of a phase reference PD analyzer (PRPDA) system, together with a video recording system, also gives information relevant to discharge mechanisms and film degradation processes. The test assembly is described and some results, relevant to polymeric films of different thickness, are presented. >
介绍了一种新的测试装置,用于测试聚合物和陶瓷薄膜在局部放电作用下的耐久性。如果实验是在受控的环境条件下进行的(例如,相对湿度),测试程序给出的击穿时间显示低散射。给出了不同测试条件对击穿次数和相关数据散射的影响。采用相位参考PD分析仪(PRPDA)系统和视频记录系统,还提供了放电机制和薄膜降解过程的相关信息。描述了测试装置,并给出了与不同厚度聚合物薄膜有关的一些结果。>
{"title":"Measuring the endurance of films in partial discharges","authors":"R. Bozzo, L. Centurioni, F. Guastavino","doi":"10.1109/14.249378","DOIUrl":"https://doi.org/10.1109/14.249378","url":null,"abstract":"A new test assembly for measuring the endurance of polymeric and ceramic films under the action of partial discharges (PDs) is presented. If experiments are performed under controlled ambient conditions (i.e., relative humidity), the test procedure gives times to breakdown which show low scatter. The effects of different test conditions on the times to breakdown and relevant data scatter are presented. The adoption of a phase reference PD analyzer (PRPDA) system, together with a video recording system, also gives information relevant to discharge mechanisms and film degradation processes. The test assembly is described and some results, relevant to polymeric films of different thickness, are presented. >","PeriodicalId":13105,"journal":{"name":"IEEE Transactions on Electrical Insulation","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1993-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81936945","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 33
The relation between thermal and electrical stress and the PD behavior of epoxy-resin transformers 热、电应力与环氧树脂变压器局部放电行为的关系
Pub Date : 1993-12-01 DOI: 10.1109/14.249374
H. Borsi
The partial discharge (PD) behavior of epoxy resin transformer coils in a temperature range between -30 and 180 degrees C is discussed. In particular, the PD inception voltage, which is a very important parameter for the judgement of the PD characteristic of a transformer over the temperature range, is considered. The PD inception voltage is determined at different static temperatures in step tests. The tempering of the coils occurs from the outside by submerging the oil in tempered fluid,as well as from the inside, with the help of current losses. Models of HV coils of distribution transformers are used as specimens. The dependencies between the PD inception voltage of the coils and parameters such as wire insulation and inner or outer tempering are determined and discussed. The results of long-term tests in which five coils are stressed with a voltage of 1.75 kV at a temperature of 175 degrees C for a duration of one year are presented. During this time PD measurements with a sensitivity of 2 pC were carried out. >
讨论了环氧树脂变压器线圈在-30 ~ 180℃温度范围内的局部放电行为。特别是考虑了局部放电起始电压,这是判断变压器局部放电特性在温度范围内的重要参数。在步进试验中,确定了不同静态温度下的局部放电起始电压。线圈的回火发生在外部,通过将油浸入回火流体中,也发生在内部,借助电流损失。以配电变压器高压线圈模型为试样。确定并讨论了线圈的PD起始电压与导线绝缘、内外回火等参数之间的依赖关系。本文介绍了在175℃温度下,五个线圈在1.75 kV电压下受力一年的长期试验结果。在此期间,进行了灵敏度为2 pC的PD测量。>
{"title":"The relation between thermal and electrical stress and the PD behavior of epoxy-resin transformers","authors":"H. Borsi","doi":"10.1109/14.249374","DOIUrl":"https://doi.org/10.1109/14.249374","url":null,"abstract":"The partial discharge (PD) behavior of epoxy resin transformer coils in a temperature range between -30 and 180 degrees C is discussed. In particular, the PD inception voltage, which is a very important parameter for the judgement of the PD characteristic of a transformer over the temperature range, is considered. The PD inception voltage is determined at different static temperatures in step tests. The tempering of the coils occurs from the outside by submerging the oil in tempered fluid,as well as from the inside, with the help of current losses. Models of HV coils of distribution transformers are used as specimens. The dependencies between the PD inception voltage of the coils and parameters such as wire insulation and inner or outer tempering are determined and discussed. The results of long-term tests in which five coils are stressed with a voltage of 1.75 kV at a temperature of 175 degrees C for a duration of one year are presented. During this time PD measurements with a sensitivity of 2 pC were carried out. >","PeriodicalId":13105,"journal":{"name":"IEEE Transactions on Electrical Insulation","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1993-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"74849975","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
Partial discharges and streamers in liquid dielectrics-the significance of the inception voltage 液体电介质中的局部放电和流光——起始电压的意义
Pub Date : 1993-12-01 DOI: 10.1109/14.249367
E. Forster
Recent studies have determined the partial discharge inception voltage (PDIV) of several practical insulating oils using conventional PD measurements. They show that the PDIV is a reasonably reproducible quantity. Independently, using electrooptical techniques, the streamer inception voltages (SIVs) in these liquids have been measured. These SIV values are found to be reproducible, within experimental error. Both techniques yield similar inception values. These results suggest that the PD and streamer phenomena are closely related. It is shown that the PDIV is independent of the gap and hence the average electric field. The SIV is found to be independent of the applied voltage. These observations suggest that the inception of both phenomena is controlled by the local rather than the average applied field. The experimental observations are interpreted and a theory is advanced to explain them. >
最近的研究已经用传统的局部放电测量方法确定了几种实用绝缘油的局部放电起始电压(PDIV)。它们表明PDIV是一个可合理重现的量。利用光电技术,独立地测量了这些液体中的流光起始电压(siv)。这些SIV值在实验误差范围内是可重复的。这两种技术产生相似的初始值。这些结果表明,局部放电现象与流光现象密切相关。结果表明,PDIV与间隙无关,因此与平均电场无关。发现SIV与外加电压无关。这些观察结果表明,这两种现象的开始都是由局部而不是平均应用场控制的。对实验观察结果进行了解释,并提出了一种理论来解释它们。>
{"title":"Partial discharges and streamers in liquid dielectrics-the significance of the inception voltage","authors":"E. Forster","doi":"10.1109/14.249367","DOIUrl":"https://doi.org/10.1109/14.249367","url":null,"abstract":"Recent studies have determined the partial discharge inception voltage (PDIV) of several practical insulating oils using conventional PD measurements. They show that the PDIV is a reasonably reproducible quantity. Independently, using electrooptical techniques, the streamer inception voltages (SIVs) in these liquids have been measured. These SIV values are found to be reproducible, within experimental error. Both techniques yield similar inception values. These results suggest that the PD and streamer phenomena are closely related. It is shown that the PDIV is independent of the gap and hence the average electric field. The SIV is found to be independent of the applied voltage. These observations suggest that the inception of both phenomena is controlled by the local rather than the average applied field. The experimental observations are interpreted and a theory is advanced to explain them. >","PeriodicalId":13105,"journal":{"name":"IEEE Transactions on Electrical Insulation","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1993-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77333144","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 40
On the character of different forms of partial discharge and their related terminologies 论不同形式局部放电的特点及其相关术语
Pub Date : 1993-12-01 DOI: 10.1109/14.249369
R. Bartnikas, J. Novak
Experimentally obtained partial discharge pulse forms are compared with those derived theoretically, using a mathematical model of a short gap. The calculations indicate that, with overvolted short gaps, the apparent absence of the protracted ion current tail in the overall pulse form is due to the large excess of the electron current component generated by strongly enhanced cathode emission by the photoeffect and other phenomena. Under conditions of high overvoltage the ion-impact-induced emission, the ion fluxes and, consequently, the ion current component are greatly reduced as compared to the electron current. The long ion current tail, representing not more than a few percent of the total current, passes undetected. Pulseless and pseudo-glow discharges are considered. Preferred terms to designate the different forms of partial discharges are suggested. >
利用短间隙的数学模型,将实验得到的局部放电脉冲形式与理论推导的部分放电脉冲形式进行了比较。计算结果表明,在过电压短间隙下,整个脉冲形式中明显没有离子电流尾,这是由于光电效应和其他现象强烈增强阴极发射所产生的电子电流分量大量过剩所致。在高过电压条件下,离子冲击诱导发射,离子通量,因此,离子电流成分大大减少,相比于电子电流。长离子电流尾巴,代表不超过总电流的百分之几,未被检测到。考虑了无脉冲和伪辉光放电。提出了指定不同形式的局部放电的首选术语。>
{"title":"On the character of different forms of partial discharge and their related terminologies","authors":"R. Bartnikas, J. Novak","doi":"10.1109/14.249369","DOIUrl":"https://doi.org/10.1109/14.249369","url":null,"abstract":"Experimentally obtained partial discharge pulse forms are compared with those derived theoretically, using a mathematical model of a short gap. The calculations indicate that, with overvolted short gaps, the apparent absence of the protracted ion current tail in the overall pulse form is due to the large excess of the electron current component generated by strongly enhanced cathode emission by the photoeffect and other phenomena. Under conditions of high overvoltage the ion-impact-induced emission, the ion fluxes and, consequently, the ion current component are greatly reduced as compared to the electron current. The long ion current tail, representing not more than a few percent of the total current, passes undetected. Pulseless and pseudo-glow discharges are considered. Preferred terms to designate the different forms of partial discharges are suggested. >","PeriodicalId":13105,"journal":{"name":"IEEE Transactions on Electrical Insulation","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1993-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81027081","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 97
Partial discharge measurements in dielectric liquids under impulse voltage 脉冲电压下介电液体的局部放电测量
Pub Date : 1993-12-01 DOI: 10.1109/14.249368
H. Yamashita
Current pulses caused by partial discharges (PDs) are measured using light-emitting diodes (LEDs) and fiber optics under impulse voltage conditions. This system has the advantage of having good isolation from the HV power supply and no effect from electromagnetic noise as compared with ordinary systems. It can detect a PD pulse having a half width of 3 ns, and has the capability of measuring PD pulse charges in the range of 1 to 2000 pC, when the optimum DC bias is applied. PD pulses and light emission or streamer formation in dielectric liquids are measured simultaneously by using an image converter camera. >
在脉冲电压条件下,利用发光二极管(led)和光纤测量由局部放电(pd)引起的电流脉冲。与普通系统相比,该系统具有与高压电源隔离良好,不受电磁噪声影响的优点。它可以检测半宽3ns的PD脉冲,当施加最佳直流偏压时,具有测量1 ~ 2000pc范围内PD脉冲电荷的能力。利用图像转换相机同时测量介质液体中的PD脉冲和光发射或流光形成。>
{"title":"Partial discharge measurements in dielectric liquids under impulse voltage","authors":"H. Yamashita","doi":"10.1109/14.249368","DOIUrl":"https://doi.org/10.1109/14.249368","url":null,"abstract":"Current pulses caused by partial discharges (PDs) are measured using light-emitting diodes (LEDs) and fiber optics under impulse voltage conditions. This system has the advantage of having good isolation from the HV power supply and no effect from electromagnetic noise as compared with ordinary systems. It can detect a PD pulse having a half width of 3 ns, and has the capability of measuring PD pulse charges in the range of 1 to 2000 pC, when the optimum DC bias is applied. PD pulses and light emission or streamer formation in dielectric liquids are measured simultaneously by using an image converter camera. >","PeriodicalId":13105,"journal":{"name":"IEEE Transactions on Electrical Insulation","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1993-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77981953","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 20
PD analysis of rotating AC machines 旋转交流电机的局部放电分析
Pub Date : 1993-12-01 DOI: 10.1109/14.249371
A. Contin, G. Rabach
The problem of the interpretation of partial discharge (PD) measurements is approached by means of the shape analysis of PD amplitude distributions. Experimental cumulative PD distributions, detected insulation systems of HV rotating machine stator windings, are plotted on a Weibull graph in order to identify multiple PD sources. Examples of the application of PD distribution shape analysis as a diagnostic tool for AC HV stator insulation systems are presented and discussed. The calibration procedure and the significance of average parameters for degradation inference are reviewed. >
通过局部放电振幅分布的形状分析,探讨了局部放电测量的解释问题。实验累积PD分布,检测高压旋转电机定子绕组的绝缘系统,绘制在威布尔图上,以识别多个PD源。介绍并讨论了局部放电分布形状分析作为交流高压定子绝缘系统诊断工具的应用实例。综述了退化推理中平均参数的校准过程和意义。>
{"title":"PD analysis of rotating AC machines","authors":"A. Contin, G. Rabach","doi":"10.1109/14.249371","DOIUrl":"https://doi.org/10.1109/14.249371","url":null,"abstract":"The problem of the interpretation of partial discharge (PD) measurements is approached by means of the shape analysis of PD amplitude distributions. Experimental cumulative PD distributions, detected insulation systems of HV rotating machine stator windings, are plotted on a Weibull graph in order to identify multiple PD sources. Examples of the application of PD distribution shape analysis as a diagnostic tool for AC HV stator insulation systems are presented and discussed. The calibration procedure and the significance of average parameters for degradation inference are reviewed. >","PeriodicalId":13105,"journal":{"name":"IEEE Transactions on Electrical Insulation","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1993-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"77893773","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 31
Present state and prospects of standardization on PD measurements PD测量标准化的现状与展望
Pub Date : 1993-12-01 DOI: 10.1109/14.249363
G. Zingales
The contents of the past and present IEC Standards on partial discharge (PD) measurements are examined, in view of the preparation of a new edition. New standards should take into account the more sophisticated measuring systems produced in the last decades and their lower sensitivity to external disturbances. Little knowledge has however been added on the PD aging effects on HV apparatus. >
考虑到新版本的准备,对过去和现在的部分放电(PD)测量的IEC标准的内容进行了审查。新标准应考虑到过去几十年生产的较复杂的测量系统及其对外部干扰的较低敏感性。然而,关于PD老化对高压电器的影响却知之甚少。>
{"title":"Present state and prospects of standardization on PD measurements","authors":"G. Zingales","doi":"10.1109/14.249363","DOIUrl":"https://doi.org/10.1109/14.249363","url":null,"abstract":"The contents of the past and present IEC Standards on partial discharge (PD) measurements are examined, in view of the preparation of a new edition. New standards should take into account the more sophisticated measuring systems produced in the last decades and their lower sensitivity to external disturbances. Little knowledge has however been added on the PD aging effects on HV apparatus. >","PeriodicalId":13105,"journal":{"name":"IEEE Transactions on Electrical Insulation","volume":null,"pages":null},"PeriodicalIF":0.0,"publicationDate":"1993-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"81833888","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 6
期刊
IEEE Transactions on Electrical Insulation
全部 Acc. Chem. Res. ACS Applied Bio Materials ACS Appl. Electron. Mater. ACS Appl. Energy Mater. ACS Appl. Mater. Interfaces ACS Appl. Nano Mater. ACS Appl. Polym. Mater. ACS BIOMATER-SCI ENG ACS Catal. ACS Cent. Sci. ACS Chem. Biol. ACS Chemical Health & Safety ACS Chem. Neurosci. ACS Comb. Sci. ACS Earth Space Chem. ACS Energy Lett. ACS Infect. Dis. ACS Macro Lett. ACS Mater. Lett. ACS Med. Chem. Lett. ACS Nano ACS Omega ACS Photonics ACS Sens. ACS Sustainable Chem. Eng. ACS Synth. Biol. Anal. Chem. BIOCHEMISTRY-US Bioconjugate Chem. BIOMACROMOLECULES Chem. Res. Toxicol. Chem. Rev. Chem. Mater. CRYST GROWTH DES ENERG FUEL Environ. Sci. Technol. Environ. Sci. Technol. Lett. Eur. J. Inorg. Chem. IND ENG CHEM RES Inorg. Chem. J. Agric. Food. Chem. J. Chem. Eng. Data J. Chem. Educ. J. Chem. Inf. Model. J. Chem. Theory Comput. J. Med. Chem. J. Nat. Prod. J PROTEOME RES J. Am. Chem. Soc. LANGMUIR MACROMOLECULES Mol. Pharmaceutics Nano Lett. Org. Lett. ORG PROCESS RES DEV ORGANOMETALLICS J. Org. Chem. J. Phys. Chem. J. Phys. Chem. A J. Phys. Chem. B J. Phys. Chem. C J. Phys. Chem. Lett. Analyst Anal. Methods Biomater. Sci. Catal. Sci. Technol. Chem. Commun. Chem. Soc. Rev. CHEM EDUC RES PRACT CRYSTENGCOMM Dalton Trans. Energy Environ. Sci. ENVIRON SCI-NANO ENVIRON SCI-PROC IMP ENVIRON SCI-WAT RES Faraday Discuss. Food Funct. Green Chem. Inorg. Chem. Front. Integr. Biol. J. Anal. At. Spectrom. J. Mater. Chem. A J. Mater. Chem. B J. Mater. Chem. C Lab Chip Mater. Chem. Front. Mater. Horiz. MEDCHEMCOMM Metallomics Mol. Biosyst. Mol. Syst. Des. Eng. Nanoscale Nanoscale Horiz. Nat. Prod. Rep. New J. Chem. Org. Biomol. Chem. Org. Chem. Front. PHOTOCH PHOTOBIO SCI PCCP Polym. Chem.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1