ENERGY EFFICIENCY OF USING A CON-DITIONING SYSTEM BASED ON A GROUND HEAT PUMP

M. Bezrodny, S. Oslovskyi
{"title":"ENERGY EFFICIENCY OF USING A CON-DITIONING SYSTEM BASED ON A GROUND HEAT PUMP","authors":"M. Bezrodny, S. Oslovskyi","doi":"10.31472/ttpe.1.2022.6","DOIUrl":null,"url":null,"abstract":"The article is devoted to the study of the energy efficiency of the air conditioning system using a ground heat pump. The analysis of the English-language literary sources, which highlighted the features of the use of heat pump air conditioning systems in various climatic conditions. It is shown that the greatest effect from the use of such a scheme will be when the duration of the cold and hot periods is equal. The main temperatures at the nodal points of the circuit and the efficiency coefficient are determined. The dependences of the determining quantities on the parameters of the system are constructed. The proposed system has a significant positive effect compared to a standard split system, but it also has a drawback: for an air conditioning system with a ground source heat pump, the requirements for the thermal insulation of a building will be more stringent. Using the system all year round can significantly reduce the energy consumption for air conditioning. The application of such a solution at the design and geodetic development stage of the site will give a significant positive effect both in terms of operation and in terms of capital costs for the installation of the system.","PeriodicalId":23079,"journal":{"name":"Thermophysics and Thermal Power Engineering","volume":"20 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Thermophysics and Thermal Power Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31472/ttpe.1.2022.6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The article is devoted to the study of the energy efficiency of the air conditioning system using a ground heat pump. The analysis of the English-language literary sources, which highlighted the features of the use of heat pump air conditioning systems in various climatic conditions. It is shown that the greatest effect from the use of such a scheme will be when the duration of the cold and hot periods is equal. The main temperatures at the nodal points of the circuit and the efficiency coefficient are determined. The dependences of the determining quantities on the parameters of the system are constructed. The proposed system has a significant positive effect compared to a standard split system, but it also has a drawback: for an air conditioning system with a ground source heat pump, the requirements for the thermal insulation of a building will be more stringent. Using the system all year round can significantly reduce the energy consumption for air conditioning. The application of such a solution at the design and geodetic development stage of the site will give a significant positive effect both in terms of operation and in terms of capital costs for the installation of the system.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于地源热泵的空调系统的能源效率
本文对地源热泵空调系统的能源效率进行了研究。通过对英语文献资料的分析,突出了热泵空调系统在各种气候条件下的使用特点。结果表明,当冷热期的持续时间相等时,使用这种方案的效果最大。确定了电路各节点的主要温度和效率系数。构造了决定量对系统参数的依赖关系。与标准分体式系统相比,所提出的系统具有显著的积极作用,但它也有一个缺点:对于带有地源热泵的空调系统,对建筑物隔热的要求将更加严格。全年使用该系统可显著降低空调能耗。在场地的设计和大地测量发展阶段应用这种解决方案,将在操作和安装系统的资本成本方面产生重大的积极影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
THE FLOW OF LUBRICANT IN A NARROW WEDGE-SHAPED SLOT WITH A MOVABLE WALL IS CONSIDERED AERODYNAMICS AND MIXTURE FORMATION IN BURNERS WITH A MULTI-ROW JET FUEL SUPPLY SYSTEM IMPROVEMENT OF THERMAL MODES OF WARMING UP HIGH-TEMPERATURE UNITS METHOD OF REDUCING WATER HARDNESS SALTS AND HEAT AND MASS EXCHANGE EQUIPMENT FOR ITS IMPLEMENTATION INFLUENCE OF COMBINED DRYING OF COLLOID CAPILLARY-POROUS MATERIALS ON ENERGY EXPENDITURES
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1