A 1-to-8 GHz miniaturized dielectric spectroscopy system for chemical sensing

A. Helmy, K. Entesari
{"title":"A 1-to-8 GHz miniaturized dielectric spectroscopy system for chemical sensing","authors":"A. Helmy, K. Entesari","doi":"10.1109/MWSYM.2012.6258422","DOIUrl":null,"url":null,"abstract":"This paper presents a miniaturized broadband dielectric spectroscopy system for dielectric characterization and chemical sensing for 1-to-8 GHz frequency range. Sensor operation is based on detecting the phase shift of a signal passing through a true-time-delay (TTD) cell at the presence of an organic chemical. Cascaded TTD cells are used to improve the detection accuracy and the sensing bandwidth. Measurements with calibration show accurate detection of frequency-dependent permittivity for organic chemicals with permittivities up to 20.","PeriodicalId":6385,"journal":{"name":"2012 IEEE/MTT-S International Microwave Symposium Digest","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE/MTT-S International Microwave Symposium Digest","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/MWSYM.2012.6258422","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

This paper presents a miniaturized broadband dielectric spectroscopy system for dielectric characterization and chemical sensing for 1-to-8 GHz frequency range. Sensor operation is based on detecting the phase shift of a signal passing through a true-time-delay (TTD) cell at the presence of an organic chemical. Cascaded TTD cells are used to improve the detection accuracy and the sensing bandwidth. Measurements with calibration show accurate detection of frequency-dependent permittivity for organic chemicals with permittivities up to 20.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于化学传感的1 ~ 8 GHz小型化介电光谱系统
本文提出了一种用于1 ~ 8ghz频率范围内介质表征和化学传感的小型化宽带介质光谱系统。传感器的工作原理是检测在存在有机化学物质的情况下,通过真时延迟(TTD)细胞的信号的相移。采用级联TTD单元,提高了检测精度和传感带宽。校准测量显示准确检测频率相关的介电常数有机化学品的介电常数高达20。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A dispersion-tapered reflection soliton oscillator 4–12 GHz and 25–34 GHz cryogenic MHEMT MMIC Low Noise Amplifiers for radio astronomy 1 Gb/s wireless link at 200 GHz using heterodyne detection Overview of the research and applications of the space-spectral domain approach (SSDA) A microwave sensing system for aqueous concentration measurements based on a microwave reflectometer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1