P.J.S.B. Barratt, T.R. Brock, G. Doucas, T.J.L. Greenway, A. Henwood, A.R. Holmes, H.R. McK. Hyder, A.B. Knox, G.M. Parker , J. Takacs
{"title":"The oxford folded tandem","authors":"P.J.S.B. Barratt, T.R. Brock, G. Doucas, T.J.L. Greenway, A. Henwood, A.R. Holmes, H.R. McK. Hyder, A.B. Knox, G.M. Parker , J. Takacs","doi":"10.1016/0029-554X(81)90845-4","DOIUrl":null,"url":null,"abstract":"<div><p>The large vertical Van de Graaff in the Nuclear Physics Laboratory at Oxford University has been converted to a folded tandem with a rated terminal voltage of 10 MV. The new parts were designed and largely manufactured within the Laboratory and included the terminal, two negative ion sources, low energy and high energy beam transport and vacuum systems and a new control system. The conversion began in July 1977 and progressed so that experiments with the folded tandem began in January 1979. Excluding the value of manufacture and installation by Laboratory staff, the total cost of the conversion was £100 000, the major items of outside manufacture being the 180° magnet, the accelerator tubes and the serial data links. The main design features of the new accelerator are discussed as well as its performance during the first 18 months of operation.</p></div>","PeriodicalId":100971,"journal":{"name":"Nuclear Instruments and Methods","volume":"184 1","pages":"Pages 9-33"},"PeriodicalIF":0.0000,"publicationDate":"1981-05-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0029-554X(81)90845-4","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments and Methods","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0029554X81908454","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
The large vertical Van de Graaff in the Nuclear Physics Laboratory at Oxford University has been converted to a folded tandem with a rated terminal voltage of 10 MV. The new parts were designed and largely manufactured within the Laboratory and included the terminal, two negative ion sources, low energy and high energy beam transport and vacuum systems and a new control system. The conversion began in July 1977 and progressed so that experiments with the folded tandem began in January 1979. Excluding the value of manufacture and installation by Laboratory staff, the total cost of the conversion was £100 000, the major items of outside manufacture being the 180° magnet, the accelerator tubes and the serial data links. The main design features of the new accelerator are discussed as well as its performance during the first 18 months of operation.
牛津大学核物理实验室的大型垂直范德格拉夫(Van de Graaff)已被转换为额定端子电压为10 MV的折叠串联。新部件大部分是在实验室设计和制造的,包括终端,两个负离子源,低能和高能光束传输和真空系统以及一个新的控制系统。转换开始于1977年7月,并且进展到1979年1月开始进行折叠串联的实验。不包括实验室工作人员制造和安装的价值,转换的总成本为10万英镑,外部制造的主要项目是180°磁铁,加速器管和串行数据链路。讨论了新加速器的主要设计特点及其在前18个月运行中的性能。