G. Urban, G. Jobst, F. Keplinger, E. Aschauer, R. Fasching, A. Jachimowicz, F. Kohl
{"title":"Integrated miniaturized biosensors for clinical analyzers and in vivo applications","authors":"G. Urban, G. Jobst, F. Keplinger, E. Aschauer, R. Fasching, A. Jachimowicz, F. Kohl","doi":"10.1109/IEMBS.1992.5760904","DOIUrl":null,"url":null,"abstract":"Miniaturized thin-film biosensors integrated on a flexible substrate were developed for in vivo applications and for use in clinical analyzers. A glucose, a lactate sensor and a pH-sensor was integrated. Both enzyme sensors are based on the measurements of H2 O2 produced by the enzymes glucoseoxidase and lactateoxidase respectively. The solid state pH-sensor uses a neutral carrier membrane. The Intended use of this device is the monitoring of metabolic parameters in the intensive care unit and the operation theatre and the application in clinical analyzers. The glucose-, lactate-and pH-sensor were tested in buffer solutions, serum and whole blood showing excellent performance.","PeriodicalId":6457,"journal":{"name":"1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","volume":"35 1","pages":"157-158"},"PeriodicalIF":0.0000,"publicationDate":"1992-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IEMBS.1992.5760904","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
Miniaturized thin-film biosensors integrated on a flexible substrate were developed for in vivo applications and for use in clinical analyzers. A glucose, a lactate sensor and a pH-sensor was integrated. Both enzyme sensors are based on the measurements of H2 O2 produced by the enzymes glucoseoxidase and lactateoxidase respectively. The solid state pH-sensor uses a neutral carrier membrane. The Intended use of this device is the monitoring of metabolic parameters in the intensive care unit and the operation theatre and the application in clinical analyzers. The glucose-, lactate-and pH-sensor were tested in buffer solutions, serum and whole blood showing excellent performance.