{"title":"Some Aspects of the Technology of Lead Salt Diode Lasers Used in Gas Monitoring Systems","authors":"J. Tomm, B. Sumpf, K. Herrmann, A. Szczerbakow","doi":"10.1002/CRAT.2170220719","DOIUrl":null,"url":null,"abstract":"A rather simple method of lead salt diode laser fabrication is described. The optimization of the diffusion process forming the pn-junction is especially discussed with regards to the various carrier concentrations of the as-grown crystals. Liquid nitrogen cooled lead salt diode lasers of the described type meet all demands of a laser based air pollution monitoring device. \n \n \n \nEs wird eine verhaltnismasig einfache Methode der Bleisalzdiodenlaserherstellung erlautert. Insbesondere die Frage der Optimierung des Diffusionsprozesses, der den pn-Ubergang erzeugt, in Abhangigkeit von der Ausgangsladungstragerkonzentration der Kristalle wird diskutiert. Halbleiterinjektionslaser des beschriebenen Typs entsprechen voll allen Anforderungen, die an ein mit flussigem Stickstoff gekuhltes, mit Bleisalzalasern arbeitendes Schadstoffmesgerat gestellt werden.","PeriodicalId":17719,"journal":{"name":"July 2019","volume":"237 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"1987-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"July 2019","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/CRAT.2170220719","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
A rather simple method of lead salt diode laser fabrication is described. The optimization of the diffusion process forming the pn-junction is especially discussed with regards to the various carrier concentrations of the as-grown crystals. Liquid nitrogen cooled lead salt diode lasers of the described type meet all demands of a laser based air pollution monitoring device.
Es wird eine verhaltnismasig einfache Methode der Bleisalzdiodenlaserherstellung erlautert. Insbesondere die Frage der Optimierung des Diffusionsprozesses, der den pn-Ubergang erzeugt, in Abhangigkeit von der Ausgangsladungstragerkonzentration der Kristalle wird diskutiert. Halbleiterinjektionslaser des beschriebenen Typs entsprechen voll allen Anforderungen, die an ein mit flussigem Stickstoff gekuhltes, mit Bleisalzalasern arbeitendes Schadstoffmesgerat gestellt werden.