Optimization of a Developed Multi-Cyclone Using Response Surface Methodology (RSM) to Control Fine Particulate Emission

N. Hasyimah, M. Rashid, H. Norelyza
{"title":"Optimization of a Developed Multi-Cyclone Using Response Surface Methodology (RSM) to Control Fine Particulate Emission","authors":"N. Hasyimah, M. Rashid, H. Norelyza","doi":"10.4028/p-7540tu","DOIUrl":null,"url":null,"abstract":"The effects of increasing volumetric air flow rate and inlet particulate loading on overall collection efficiency of MR-deDuster; a developed multi-cyclone system was investigated using various segregated sizes of palm oil mill boiler fly ash. The operating conditions of the fabricated pilot plant scale of the unit were predicted theoretically and screened experimentally. Increasing volumetric air flow rate theoretically will increase the overall collection efficiency, yet the experimental results during screening stage demonstrated contradict finding when the increment of volumetric air flow rate caused the overall collection efficiency to be decreased for a constant particulate loading. Subsequently, the optimization work was done to determine the optimum operating conditions of the system using Response Surface Method (RSM) with Box-Behnken design. The parallel arrangement of multi-cyclone units proved the ability of the system to uniformly disseminate the gas flow with high volume of gas carrier. Nevertheless, excessive pressure drops between each unit of multi-cyclone due to high volumetric air flow rate should be avoided as such condition may lower the overall collection efficiency by allowing dust re-entrainment from the hopper to circulate between the cyclones. Through statistical analysis of variance (ANOVA), validation and verification studies, it is suggested that the developed pilot scale multi-cyclone unit would be able to meet the targeted limit of 150 mg/m3 for solid fuel burning equipment industry in Malaysia by operating with optimized volumetric air flow rate of 0.27 m3/s, and maximum inlet particulate loading rate and size of 2 g/m3 and 1000 μm respectively.","PeriodicalId":34329,"journal":{"name":"Journal of Electrical and Computer Engineering Innovations","volume":"43 1","pages":"21 - 29"},"PeriodicalIF":0.0000,"publicationDate":"2023-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electrical and Computer Engineering Innovations","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4028/p-7540tu","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The effects of increasing volumetric air flow rate and inlet particulate loading on overall collection efficiency of MR-deDuster; a developed multi-cyclone system was investigated using various segregated sizes of palm oil mill boiler fly ash. The operating conditions of the fabricated pilot plant scale of the unit were predicted theoretically and screened experimentally. Increasing volumetric air flow rate theoretically will increase the overall collection efficiency, yet the experimental results during screening stage demonstrated contradict finding when the increment of volumetric air flow rate caused the overall collection efficiency to be decreased for a constant particulate loading. Subsequently, the optimization work was done to determine the optimum operating conditions of the system using Response Surface Method (RSM) with Box-Behnken design. The parallel arrangement of multi-cyclone units proved the ability of the system to uniformly disseminate the gas flow with high volume of gas carrier. Nevertheless, excessive pressure drops between each unit of multi-cyclone due to high volumetric air flow rate should be avoided as such condition may lower the overall collection efficiency by allowing dust re-entrainment from the hopper to circulate between the cyclones. Through statistical analysis of variance (ANOVA), validation and verification studies, it is suggested that the developed pilot scale multi-cyclone unit would be able to meet the targeted limit of 150 mg/m3 for solid fuel burning equipment industry in Malaysia by operating with optimized volumetric air flow rate of 0.27 m3/s, and maximum inlet particulate loading rate and size of 2 g/m3 and 1000 μm respectively.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于响应面法(RSM)的多级旋风分离器细颗粒物排放控制优化
增加容积空气流量和进口颗粒负荷对mr - duster整体收集效率的影响采用不同分离粒度的棕榈油磨锅炉飞灰,研究了一种新型的多旋流器系统。对装置中试规模的运行条件进行了理论预测和实验筛选。增大体积风流量理论上会提高整体收集效率,但在颗粒负荷一定的情况下,增大体积风流量会导致整体收集效率下降,在筛选阶段的实验结果却与之矛盾。随后,采用Box-Behnken设计的响应面法(RSM)进行了优化工作,确定了系统的最佳运行条件。多旋流器并联布置,证明了该系统具有均匀分散高载气量气流的能力。然而,应避免由于高容量空气流速而导致的多旋风分离器各单元之间的压力过大,因为这种情况可能会降低整体收集效率,因为它允许从料斗中重新夹带的灰尘在旋风分离器之间循环。通过方差统计分析(ANOVA)、验证和验证研究表明,所研制的中试多旋流装置在优化容积空气流量为0.27 m3/s、最大进口颗粒负荷率为2 g/m3和颗粒尺寸为1000 μm的条件下运行,能够满足马来西亚固体燃料燃烧设备行业150mg /m3的目标限值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
12 weeks
期刊最新文献
Designing a Roundabout to Overcome Traffic Congestion at a Four-Armed Intersection Evaluation of Engineering Properties of Fired Cement Lateritic Brick Molecular Dynamics Simulation on Shocked Nanocrystalline Aluminum Experimental Investigation on Axial Ultrasonic Vibration Assisted Milling of Cr12MoV Enhancing Cable Gland Design Efficiency through TRIZ-Driven Innovation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1