Impulse breakdown characteristics and cost/benefit analysis of SF/sub 6//CCl/sub 2/F/sub 2//CO/sub 2/ mixtures

D. Raghavender, M. Naidu
{"title":"Impulse breakdown characteristics and cost/benefit analysis of SF/sub 6//CCl/sub 2/F/sub 2//CO/sub 2/ mixtures","authors":"D. Raghavender, M. Naidu","doi":"10.1109/CEIDP.1989.69594","DOIUrl":null,"url":null,"abstract":"A comprehensive study has been carried out in SF/sub 6//CCl/sub 2/F/sub 2//CO/sub 2/ mixtures to measure 50% breakdown voltages V/sub 50/ using both positive and negative polarity lightning impulse (1.2/50 mu s) voltages under nonuniform fields (5-mm rod, 230-mm plane electrode) over a pressure range of 0.1 to 0.5 MPa for a gap spacing of 20 mm. The sum of SF/sub 6/ and CCl/sub 2/F/sub 2/ concentrations in the mixture was always maintained in the range of 21 to 40%, the rest being CO/sub 2/. Among the different sets of SF/sub 6//CCl/sub 2/F/sub 2//CO/sub 2/ mixtures studied, two ternary mixtures, namely 20% SF/sub 6//20% CCl/sub 2/F/sub 2//60% CO/sub 2/ and 30% SF/sub 6//10% CCl/sub 2/F/sub 2//60% CO/sub 2/, were found superior to SF/sub 6/. From the known gas content in the mixtures and from the measured breakdown voltages, a cost/benefit analysis has been carried out for the various mixtures investigated. A striking feature of this analysis is that the most promising ternary gas mixture, namely 30% SF/sub 6//10% CCl/sub 2/-F/sub 2//60% CO/sub 2/, costs only 33% as much as pure SF/sub 6/, giving 100% to 170% positive breakdown strength, and 90 to 100% negative breakdown strength as compared to that of pure SF/sub 6/.<<ETX>>","PeriodicalId":10719,"journal":{"name":"Conference on Electrical Insulation and Dielectric Phenomena,","volume":"9 1","pages":"489-494"},"PeriodicalIF":0.0000,"publicationDate":"1989-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference on Electrical Insulation and Dielectric Phenomena,","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1989.69594","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

A comprehensive study has been carried out in SF/sub 6//CCl/sub 2/F/sub 2//CO/sub 2/ mixtures to measure 50% breakdown voltages V/sub 50/ using both positive and negative polarity lightning impulse (1.2/50 mu s) voltages under nonuniform fields (5-mm rod, 230-mm plane electrode) over a pressure range of 0.1 to 0.5 MPa for a gap spacing of 20 mm. The sum of SF/sub 6/ and CCl/sub 2/F/sub 2/ concentrations in the mixture was always maintained in the range of 21 to 40%, the rest being CO/sub 2/. Among the different sets of SF/sub 6//CCl/sub 2/F/sub 2//CO/sub 2/ mixtures studied, two ternary mixtures, namely 20% SF/sub 6//20% CCl/sub 2/F/sub 2//60% CO/sub 2/ and 30% SF/sub 6//10% CCl/sub 2/F/sub 2//60% CO/sub 2/, were found superior to SF/sub 6/. From the known gas content in the mixtures and from the measured breakdown voltages, a cost/benefit analysis has been carried out for the various mixtures investigated. A striking feature of this analysis is that the most promising ternary gas mixture, namely 30% SF/sub 6//10% CCl/sub 2/-F/sub 2//60% CO/sub 2/, costs only 33% as much as pure SF/sub 6/, giving 100% to 170% positive breakdown strength, and 90 to 100% negative breakdown strength as compared to that of pure SF/sub 6/.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
SF/sub 6//CCl/sub 2/F/sub 2//CO/sub 2/混合料脉冲击穿特性及成本效益分析
对SF/sub 6//CCl/sub 2/F/sub 2//CO/sub 2/混合物进行了全面研究,在非均匀场(5毫米棒,230毫米平面电极)压力范围为0.1 ~ 0.5 MPa,间隙为20毫米的条件下,使用正负极性雷击电压(1.2/50 μ s)测量50%击穿电压V/sub 50/。混合物中SF/sub - 6/和CCl/sub - 2/F/sub - 2/的浓度总和始终保持在21% ~ 40%的范围内,其余为CO/sub - 2/。在不同配比的SF/sub 6//CCl/sub 2/F/sub 2/ CO/sub 2/混合物中,20% SF/sub 6//20% CCl/sub 2/F/sub 2//60% CO/sub 2/和30% SF/sub 6//10% CCl/sub 2/F/sub 2//60% CO/sub 2/均优于SF/sub 6/。根据混合物中已知的气体含量和测量的击穿电压,对所研究的各种混合物进行了成本/效益分析。该分析的一个显著特征是,最有前途的三元气体混合物,即30% SF/sub 6//10% CCl/sub 2/-F/sub 2//60% CO/sub 2/,成本仅为纯SF/sub 6/的33%,与纯SF/sub 6/相比,其正击穿强度为100%至170%,负击穿强度为90%至100%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Exploration of self-produced vacuum ultraviolet radiation from dielectric surface flashover at atmospheric pressure Transient voltage and injection in insulators Determination of sparking voltage and residual voltage of a void included in an electrical insulation system Thermally stimulated discharge currents in high temperature dielectrics High temperature studies of perfluoroalkoxy (PFA) film (for HV capacitors)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1