Simultaneous Quantitative Estimation of Lisinopril and Hydrochlorothiazide Residues Using HPLC for Cleaning Validation

IF 0.5 Q4 CHEMISTRY, MULTIDISCIPLINARY Chemistry Journal of Moldova Pub Date : 2020-06-01 DOI:10.19261/cjm.2020.669
I. Rubashvili, Natela Karukhnishvili, Khatuna Makharadze
{"title":"Simultaneous Quantitative Estimation of Lisinopril and Hydrochlorothiazide Residues Using HPLC for Cleaning Validation","authors":"I. Rubashvili, Natela Karukhnishvili, Khatuna Makharadze","doi":"10.19261/cjm.2020.669","DOIUrl":null,"url":null,"abstract":"The aim of this study was to develop and validate direct swab and indirect rinse sampling procedures and a high performance liquid chromatography (HPLC) method for simultaneous quantitative estimation of residues of active pharmaceutical ingredients (API) – lisinopril and hydrochlorothiazide (HCT) in cleaning control samples collected from pharmaceutical manufacturing equipment surfaces after manufacturing of lisinopril/hydrochlorothiazide 20/25 mg uncoated tablets. The swab and rinse sampling procedures were developed and validated in order to obtain a suitable and good recovery (>80%). The acceptance limits of the above-mentioned APIs on the manufacturing equipment surfaces have been established based on pharmacological and toxicological criteria. The new, rapid, specific and selective, developed HPLC method for simultaneous quantitative determination of lisinopril and HCT residues was validated with respect to robustness, system suitability test, specificity, linearity-range, precision, limits of detection and quantitation. The stability of APIs solutions and membrane filter compatibility were studied as well. The method validation was carried out according to ICH Q2 guideline and United States Pharamcopeia requirements. The limit of detection and the limit of quantitation for lisinopril were 0.039 μg/mL and 0.155 μg/mL and for HCT 0.012 μg/mL and 0.025 μg/mL, respectively.","PeriodicalId":9922,"journal":{"name":"Chemistry Journal of Moldova","volume":"5 1","pages":""},"PeriodicalIF":0.5000,"publicationDate":"2020-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemistry Journal of Moldova","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.19261/cjm.2020.669","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

The aim of this study was to develop and validate direct swab and indirect rinse sampling procedures and a high performance liquid chromatography (HPLC) method for simultaneous quantitative estimation of residues of active pharmaceutical ingredients (API) – lisinopril and hydrochlorothiazide (HCT) in cleaning control samples collected from pharmaceutical manufacturing equipment surfaces after manufacturing of lisinopril/hydrochlorothiazide 20/25 mg uncoated tablets. The swab and rinse sampling procedures were developed and validated in order to obtain a suitable and good recovery (>80%). The acceptance limits of the above-mentioned APIs on the manufacturing equipment surfaces have been established based on pharmacological and toxicological criteria. The new, rapid, specific and selective, developed HPLC method for simultaneous quantitative determination of lisinopril and HCT residues was validated with respect to robustness, system suitability test, specificity, linearity-range, precision, limits of detection and quantitation. The stability of APIs solutions and membrane filter compatibility were studied as well. The method validation was carried out according to ICH Q2 guideline and United States Pharamcopeia requirements. The limit of detection and the limit of quantitation for lisinopril were 0.039 μg/mL and 0.155 μg/mL and for HCT 0.012 μg/mL and 0.025 μg/mL, respectively.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
高效液相色谱法同时定量测定赖诺普利和氢氯噻嗪的残留
本研究的目的是建立并验证直接拭子取样和间接冲洗取样方法,以及高效液相色谱法(HPLC)同时定量测定赖诺普利/氢氯噻嗪20/ 25mg无包衣片剂生产后从制药设备表面采集的清洁对照样品中活性药物成分(API) -赖诺普利和氢氯噻嗪(HCT)残留量。开发并验证了拭子和冲洗取样程序,以获得合适且良好的回收率(bbb80 %)。上述原料药在生产设备表面的可接受限度已根据药理学和毒理学标准确定。通过鲁棒性、系统适用性、特异性、线性范围、精密度、检出限和定量等方面验证了建立的高效液相色谱法同时定量测定赖诺普利和HCT残留的新方法。研究了原料药溶液的稳定性和膜过滤器的相容性。方法验证按照ICH Q2指南和美国药典要求进行。赖诺普利的检测限和定量限分别为0.039 μg/mL和0.155 μg/mL, HCT的检测限和定量限分别为0.012 μg/mL和0.025 μg/mL。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Chemistry Journal of Moldova
Chemistry Journal of Moldova CHEMISTRY, MULTIDISCIPLINARY-
CiteScore
0.90
自引率
20.00%
发文量
8
审稿时长
12 weeks
期刊介绍: "Chemistry Journal of Moldova. General, Industrial and Ecological Chemistry" seeks to publish experimental or theoretical research results of outstanding significance and timeliness in all fields of Chemistry, including Industrial and Ecological Chemistry. The main goal of this edition is strengthening the Chemical Society of Moldova, following development of research in Moldovan chemical institutions and promotion of their collaboration with international chemical community. Manuscripts are welcome from all countries.
期刊最新文献
On the calculation of lanthanide systems. The spectral parameters of praseodymium trivalent ion Spontaneous symmetry breaking as a law of nature Isothermal section of the La2O3-Lu2O33-Er2O3 ternary phase diagram at 1250°С Crystal structure and NMR spectroscopic characterization of 1,5-bis(2-hydroxy-3-methoxybenzylidene)carbonohydrazide Antioxidant properties of some plant extracts and effect of their addition on the oxidation stability of biodiesel
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1