Evaluation of different breast implants for rupture and durability after implantation

IF 0.1 Q4 SURGERY Turkish Journal of Plastic Surgery Pub Date : 2023-01-01 DOI:10.4103/tjps.tjps_29_22
Safvet Ors
{"title":"Evaluation of different breast implants for rupture and durability after implantation","authors":"Safvet Ors","doi":"10.4103/tjps.tjps_29_22","DOIUrl":null,"url":null,"abstract":"Aim: This study includes the evaluation of 84 implants removed after an average of 10 years from 42 patients who underwent augmentation mammoplasty and augmentation mastopexy at various centers over a 20-year period. Patients and Methods: Implants from patients who were all women aged between 28-60 years were evaluated after an average of 10 years following breast implantation. Preoperative physical examination, ultrasound examination and magnetic resonance imaging (MRI) were performed. Breast implants were removed from 42 patients for various reasons. The capsules and the free fluid removed with the implants underwent pathological and cytological evaluation. 84 implants that were removed were evaluated and scored for rupture, gel leakage, presence of air in the gel, changes in shell structure, and base deformities. Implants without any deformity were given a full score of 10, while score reduction was made according to various types of deformities seen in other implants. The average score of each implant brand was compared to other brands. Results: Rupture was observed in 23 of a total of 84 implants, while implant deformities such as gel leakage, air presence in the gel, decreased elasticity, base deformity and thinning of the shell were also present. Among all, 16 implants received a full score. The durability of the implants in the human body and the damage they received were classified according to their scores. Those with a score of eight and above were classified as high, those with a score between 6-8 were classified as medium, and those with a score of less than six were classified as implants with low endurance. Most of the implants evaluated here had low to medium endurance. The volume of one of the ruptured implants was 200 mL, while the rest ranged from 275-400 mL. Bilateral rupture was observed in one patient with a McGhanR implant, which had stayed in the human body the longest (15 years). Apart from this, all ruptures in other cases were unilateral. In some of the implants of EurosiliconeR(three implants), McGhanR(two implants), NatrellaR(one implant), RofilR(one implant) and PolytechR(one implant), it was observed that the implant shell was completely torn, fragmented and disintegrated, and the gel was diffused into the capsule. Shell decay was much higher especially in EurosiliconeR, RofilR and McGhanR brands. The durability of the implants was classified according to their scores. High endurance implants were those with a score of eight and higher: MentorR, SilimedR, MotivaR, and ArionR. Medium endurance implants were those with a score between 6-8: EurosiliconeR, PolytechR, McGhanR, and NatrellaR. Low endurance implants were those with a score of six and lower: RofilR and PipR. Conclusions: Occurrence of rupture and various complications increase in implants especially after 10 years. Often from certain brands, particularly the high-volume implants, rupture more easily in time. Close follow-up should be planned for patients who have had implants for more than 10 years, considering the duration, implant brand and volume.","PeriodicalId":42065,"journal":{"name":"Turkish Journal of Plastic Surgery","volume":null,"pages":null},"PeriodicalIF":0.1000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Turkish Journal of Plastic Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/tjps.tjps_29_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Aim: This study includes the evaluation of 84 implants removed after an average of 10 years from 42 patients who underwent augmentation mammoplasty and augmentation mastopexy at various centers over a 20-year period. Patients and Methods: Implants from patients who were all women aged between 28-60 years were evaluated after an average of 10 years following breast implantation. Preoperative physical examination, ultrasound examination and magnetic resonance imaging (MRI) were performed. Breast implants were removed from 42 patients for various reasons. The capsules and the free fluid removed with the implants underwent pathological and cytological evaluation. 84 implants that were removed were evaluated and scored for rupture, gel leakage, presence of air in the gel, changes in shell structure, and base deformities. Implants without any deformity were given a full score of 10, while score reduction was made according to various types of deformities seen in other implants. The average score of each implant brand was compared to other brands. Results: Rupture was observed in 23 of a total of 84 implants, while implant deformities such as gel leakage, air presence in the gel, decreased elasticity, base deformity and thinning of the shell were also present. Among all, 16 implants received a full score. The durability of the implants in the human body and the damage they received were classified according to their scores. Those with a score of eight and above were classified as high, those with a score between 6-8 were classified as medium, and those with a score of less than six were classified as implants with low endurance. Most of the implants evaluated here had low to medium endurance. The volume of one of the ruptured implants was 200 mL, while the rest ranged from 275-400 mL. Bilateral rupture was observed in one patient with a McGhanR implant, which had stayed in the human body the longest (15 years). Apart from this, all ruptures in other cases were unilateral. In some of the implants of EurosiliconeR(three implants), McGhanR(two implants), NatrellaR(one implant), RofilR(one implant) and PolytechR(one implant), it was observed that the implant shell was completely torn, fragmented and disintegrated, and the gel was diffused into the capsule. Shell decay was much higher especially in EurosiliconeR, RofilR and McGhanR brands. The durability of the implants was classified according to their scores. High endurance implants were those with a score of eight and higher: MentorR, SilimedR, MotivaR, and ArionR. Medium endurance implants were those with a score between 6-8: EurosiliconeR, PolytechR, McGhanR, and NatrellaR. Low endurance implants were those with a score of six and lower: RofilR and PipR. Conclusions: Occurrence of rupture and various complications increase in implants especially after 10 years. Often from certain brands, particularly the high-volume implants, rupture more easily in time. Close follow-up should be planned for patients who have had implants for more than 10 years, considering the duration, implant brand and volume.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
不同乳房植入物对植入后破裂和耐久性的评价
目的:本研究包括对42名20年间在不同中心接受隆胸和乳房切除术的患者平均10年后取出的84个假体进行评估。患者和方法:年龄在28-60岁之间的女性患者在乳房植入后平均10年后进行评估。术前行体格检查、超声检查、磁共振成像(MRI)检查。42名患者因各种原因切除了乳房植入物。用植入物取出的胶囊和游离液进行病理和细胞学评估。对取出的84个植入物进行了评估和评分,包括破裂、凝胶泄漏、凝胶中存在空气、外壳结构变化和基底畸形。无畸形种植体满分为10分,其他种植体根据不同类型的畸形进行扣分。将每个种植体品牌的平均得分与其他品牌进行比较。结果:84例种植体中有23例发生破裂,同时出现凝胶渗漏、凝胶中存在空气、弹性降低、基底畸形和外壳变薄等种植体畸形。其中16个植入物获得满分。根据这些植入物在人体中的耐久性和它们所受到的损害进行分类。8分及以上为高,6-8分为中,6分以下为低耐力种植体。这里评估的大多数植入物具有低到中等的耐力。其中一个破裂的植入物的体积为200毫升,而其余的则在275-400毫升之间。在一名使用McGhanR植入物的患者中观察到双侧破裂,该植入物在人体中停留时间最长(15年)。除此之外,其他病例均为单侧破裂。在eurosiloner(3个)、McGhanR(2个)、NatrellaR(1个)、RofilR(1个)和PolytechR(1个)的部分种植体中,观察到种植体外壳完全撕裂、破碎、崩解,凝胶扩散到被膜中。特别是eurosiloner、RofilR和McGhanR品牌的壳衰变要高得多。根据他们的分数对植入物的耐久性进行分类。高耐力植入物是那些得分在8分及以上的植入物:MentorR、silmedr、MotivaR和ArionR。中等耐力植入物是那些得分在6-8之间的植入物:EurosiliconeR、PolytechR、McGhanR和NatrellaR。低耐力植入物是指RofilR和PipR得分在6分及以下的植入物。结论:种植体破裂及各种并发症的发生率在10年后明显增加。通常来自某些品牌,特别是大批量的植入物,更容易及时破裂。对于种植时间超过10年的患者,应考虑种植时间、种植品牌、种植体积等因素,进行密切随访。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
8
审稿时长
28 weeks
期刊最新文献
Glomus tumors of the digit: A retrospective analysis of clinical and functional outcomes The effect of deferoxamine on fat graft survival in tamoxifen use: An experimental study Nasal reconstruction in a rare case of unilateral arhinia in bosma arhinia microphthalmia syndrome A complication after radiofrequency ablation: Skin necrosis Comparative analysis of speech outcomes in the treatment of velopharyngeal insufficiency: Traditional superior-based pharyngeal flap and pharyngeal flap combined with radical intravelar veloplasty
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1