Phase analysis of discharge magnitude distributions inside a small void and its applications to diagnosis of deteriorating insulations

T. Ito, K. Jogan, T. Saito, Y. Ehara
{"title":"Phase analysis of discharge magnitude distributions inside a small void and its applications to diagnosis of deteriorating insulations","authors":"T. Ito, K. Jogan, T. Saito, Y. Ehara","doi":"10.1109/CEIDP.1989.69532","DOIUrl":null,"url":null,"abstract":"A breakdown phenomenon of electrical equipment due to the deterioration of insulation was investigated. The degree of deterioration or breakdown of the insulating system was predicted from the distribution of induced electric charges inside small voids in an insulator-the discharge magnitude distribution. This distribution was measured by a special internal-discharge pulse measurement system, which analyzes it according to the phase area of the applied AC 50-Hz voltage. This technique was used to investigate tree progression in the microvoid of PMMA (polymethyl methacrylate). The density and the growing speed of the trees are analyzed in terms of the discharge magnitude distributions.<<ETX>>","PeriodicalId":10719,"journal":{"name":"Conference on Electrical Insulation and Dielectric Phenomena,","volume":"30 1","pages":"111-116"},"PeriodicalIF":0.0000,"publicationDate":"1989-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference on Electrical Insulation and Dielectric Phenomena,","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.1989.69532","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

A breakdown phenomenon of electrical equipment due to the deterioration of insulation was investigated. The degree of deterioration or breakdown of the insulating system was predicted from the distribution of induced electric charges inside small voids in an insulator-the discharge magnitude distribution. This distribution was measured by a special internal-discharge pulse measurement system, which analyzes it according to the phase area of the applied AC 50-Hz voltage. This technique was used to investigate tree progression in the microvoid of PMMA (polymethyl methacrylate). The density and the growing speed of the trees are analyzed in terms of the discharge magnitude distributions.<>
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
小空隙内放电幅度分布的相位分析及其在绝缘劣化诊断中的应用
研究了电气设备因绝缘劣化而发生击穿的现象。根据绝缘子内小空隙内的感应电荷分布,即放电幅度分布,可以预测绝缘系统劣化或击穿的程度。该分布由专用的内放电脉冲测量系统测量,并根据外加交流50hz电压的相面积进行分析。该技术用于研究PMMA(聚甲基丙烯酸甲酯)微孔中的树形进展。根据流量大小分布分析了树木的密度和生长速度
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Exploration of self-produced vacuum ultraviolet radiation from dielectric surface flashover at atmospheric pressure Transient voltage and injection in insulators Determination of sparking voltage and residual voltage of a void included in an electrical insulation system Thermally stimulated discharge currents in high temperature dielectrics High temperature studies of perfluoroalkoxy (PFA) film (for HV capacitors)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1