Comparison of commercially available detectors used for the dosimetry of the High Energy Electron Beams.

Olga Bąk, H. Szweda
{"title":"Comparison of commercially available detectors used for the dosimetry of the High Energy Electron Beams.","authors":"Olga Bąk, H. Szweda","doi":"10.21641/los.2022.19.1.221","DOIUrl":null,"url":null,"abstract":"In modern radiotherapy, electron beams are used less and less often. However, there are still techniques where this type of particles is irreplaceable, like intraoperative radiotherapy (IORT) or total skin electron irradiation (TSEI). Due to low range of electrons penetrating the medium, dosimetric measurements and beam characteristics are challenging. One of the most important steps during this process is to select the right detector in order to collect reliable data. The purpose of this work was to perform beam characteristics using six commercially available detectors: Semiflex 3D (Type 31021), Advanced Markus (Type 34045), Markus (Type 23343), Roos (Type 34001), microDiamond (Type 60019), Diode E (Type 60017). Collected data shows various parameters describing electron beams, depending on the used detector. Obtained results showed that the most useful detector for beam characteristics is microDiamond Type 60019. Thanks to the very small effective volume, microDiamond showed a superior spatial resolution, which is especially handful during the measurements of dose profiles, allowing estimating beam parameters very precisely.","PeriodicalId":18098,"journal":{"name":"Letters in Oncology Science","volume":"269 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Letters in Oncology Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21641/los.2022.19.1.221","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In modern radiotherapy, electron beams are used less and less often. However, there are still techniques where this type of particles is irreplaceable, like intraoperative radiotherapy (IORT) or total skin electron irradiation (TSEI). Due to low range of electrons penetrating the medium, dosimetric measurements and beam characteristics are challenging. One of the most important steps during this process is to select the right detector in order to collect reliable data. The purpose of this work was to perform beam characteristics using six commercially available detectors: Semiflex 3D (Type 31021), Advanced Markus (Type 34045), Markus (Type 23343), Roos (Type 34001), microDiamond (Type 60019), Diode E (Type 60017). Collected data shows various parameters describing electron beams, depending on the used detector. Obtained results showed that the most useful detector for beam characteristics is microDiamond Type 60019. Thanks to the very small effective volume, microDiamond showed a superior spatial resolution, which is especially handful during the measurements of dose profiles, allowing estimating beam parameters very precisely.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于高能电子束剂量测定的市售探测器的比较。
在现代放射治疗中,电子束的使用越来越少。然而,仍然有一些技术,这种类型的颗粒是不可替代的,如术中放疗(IORT)或全皮肤电子照射(TSEI)。由于穿透介质的电子范围很低,剂量测量和光束特性具有挑战性。在这个过程中最重要的步骤之一是选择正确的探测器,以收集可靠的数据。这项工作的目的是使用六种市售探测器执行光束特性:Semiflex 3D(31021型),Advanced Markus(34045型),Markus(23343型),Roos(34001型),microDiamond(60019型),Diode E(60017型)。收集到的数据显示了描述电子束的各种参数,这取决于所使用的探测器。结果表明,60019型微金刚石是测量光束特性最有用的探测器。由于有效体积非常小,microDiamond显示出优越的空间分辨率,特别是在剂量谱测量期间,可以非常精确地估计光束参数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Teranostyka raka stercza Porównanie technik planowania radioterapii w nowotworze piersi Dawki pochodzące z obrazowania w radioterapii sterowanej obrazem Metody obrazowania w radioterapii sterowanej obrazem Comparison of the isocenter verification methods and calculating imaging offset of medical linear accelerators.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1