{"title":"Modification of the Sedimentation Unit with Continuous Discharges Flow (CDF) as a New Method to Increase Turbidity Removal in Raw Water","authors":"Ridwan Ridwan, R. Afrianita, Yogi Kurniawan","doi":"10.25077/AIJASET.V1I1.6","DOIUrl":null,"url":null,"abstract":"This study applies a new method to remove the turbidity of raw water in the sedimentation unit called CDF sedimentation using the working principle of a leaky tank at the bottom of the tank. The test was carried out on a laboratory scale reactor of 240 L/hour for 6 hours consisting of a waterfall coagulation unit for 5 seconds and alum as a coagulant. perforated wall flocculation unit with 30 minutes detention time and 1 hour CDF sedimentation unit. The study was conducted with 4 variations of CDF, namely 0%, 1%, 3%, and 5% with turbidity of 75.25 NTU. The results showed the greater the CDF value, the greater the decrease in turbidity that occurred. The highest level of turbidity removal occurred at 5% CDF value with an efficiency of 91,09%, a correlation value -0,927, and a significance value of 0,00 < 0,05. CDF value gives an influence on Reynolds numbers and Froude numbers in sedimentation units where Reynolds numbers are in the range 65,71-76,75 and Froude numbers 1,96x10-4-2,29x10-4. This shows the Reynolds number and the Froude number will get bigger as the value of the CDF and still matches the design criteria of the laminar.\nKeywords: The CDF sedimentation, Efficiency, and Turbidity.","PeriodicalId":7884,"journal":{"name":"Andalasian International Journal of Applied Science, Engineering and Technology","volume":"583 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-05-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Andalasian International Journal of Applied Science, Engineering and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.25077/AIJASET.V1I1.6","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
This study applies a new method to remove the turbidity of raw water in the sedimentation unit called CDF sedimentation using the working principle of a leaky tank at the bottom of the tank. The test was carried out on a laboratory scale reactor of 240 L/hour for 6 hours consisting of a waterfall coagulation unit for 5 seconds and alum as a coagulant. perforated wall flocculation unit with 30 minutes detention time and 1 hour CDF sedimentation unit. The study was conducted with 4 variations of CDF, namely 0%, 1%, 3%, and 5% with turbidity of 75.25 NTU. The results showed the greater the CDF value, the greater the decrease in turbidity that occurred. The highest level of turbidity removal occurred at 5% CDF value with an efficiency of 91,09%, a correlation value -0,927, and a significance value of 0,00 < 0,05. CDF value gives an influence on Reynolds numbers and Froude numbers in sedimentation units where Reynolds numbers are in the range 65,71-76,75 and Froude numbers 1,96x10-4-2,29x10-4. This shows the Reynolds number and the Froude number will get bigger as the value of the CDF and still matches the design criteria of the laminar.
Keywords: The CDF sedimentation, Efficiency, and Turbidity.