{"title":"Travelling-wave Fast-transient ESD Simulation","authors":"K. Balmain, F. Rayal","doi":"10.1109/ISEMC.1992.626142","DOIUrl":null,"url":null,"abstract":"Human electrostatic discharge is discussed as a travellingwave process, with the objective of simulating the initial nanosecond-scale current impulse. The approach presented uses swept-frequency impedance measurements at the \"fingertip\" to establish equivalence between the human subject and the simulator which is a lossy dielectric strip. The impedance measurements at the fingertip are used for approximate FFT calculation of transient discharge current. Time-domain arc discharge current measurements for the human subject and the simulator are presented for comparison. Also presented are method-of-moments calculations of time-domain discharge currents, using a loaded wire grid representation for the lossy dielectric strip simulator.","PeriodicalId":93568,"journal":{"name":"IEEE International Symposium on Electromagnetic Compatibility : [proceedings]. IEEE International Symposium on Electromagnetic Compatibility","volume":"18 1","pages":"455-459"},"PeriodicalIF":0.0000,"publicationDate":"1992-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE International Symposium on Electromagnetic Compatibility : [proceedings]. IEEE International Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.1992.626142","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9
Abstract
Human electrostatic discharge is discussed as a travellingwave process, with the objective of simulating the initial nanosecond-scale current impulse. The approach presented uses swept-frequency impedance measurements at the "fingertip" to establish equivalence between the human subject and the simulator which is a lossy dielectric strip. The impedance measurements at the fingertip are used for approximate FFT calculation of transient discharge current. Time-domain arc discharge current measurements for the human subject and the simulator are presented for comparison. Also presented are method-of-moments calculations of time-domain discharge currents, using a loaded wire grid representation for the lossy dielectric strip simulator.