DEVELOPMENT OF A PORTABLE BLOOD POTASSIUM MONITORING DEVICE FOR DIALYSIS PATIENTS.

IF 4.2 2区 农林科学 Q1 HORTICULTURE Scientia Horticulturae Pub Date : 2020-04-01 Epub Date: 2020-07-27 DOI:10.1115/dmd2020-9066
Parth Vora, Miguel Inserni, Alan Lai, Maya M Lapinski, Justin Wang, Min Jae Kim, Diane Lee, Rebecca Yu, Amir Manbachi, Mohamed G Atta
{"title":"DEVELOPMENT OF A PORTABLE BLOOD POTASSIUM MONITORING DEVICE FOR DIALYSIS PATIENTS.","authors":"Parth Vora, Miguel Inserni, Alan Lai, Maya M Lapinski, Justin Wang, Min Jae Kim, Diane Lee, Rebecca Yu, Amir Manbachi, Mohamed G Atta","doi":"10.1115/dmd2020-9066","DOIUrl":null,"url":null,"abstract":"<p><p>Approximately 500,000 dialysis patients in America are at a high risk of hyperkalemia, a condition where blood potassium becomes elevated above normal levels. Hyperkalemia is extremely dangerous, as it can result in severe cardiac complications if untreated. Hyperkalemia may be silent or present vague symptoms until those complications develop, at which point patients require emergency medical care. However, if patients have the ability to measure their potassium levels at home, they could detect hyperkalemia before it reaches a dangerous stage, and seek preventative medical care to avoid severe complications. Therefore, we have designed a novel device allowing patients to measure their blood potassium levels at home. The workflow of our solution is as follows: (1) patients obtain a blood sample from a finger prick, (2) potassium concentration is measured with an ion specific electrode (ISE), and (3) the device displays their potassium levels and a recommended course of action based on their hyperkalemic risk. We validate our solution with three major tests. First, our portable ISE technology must accurately measure potassium concentration in blood samples. Second, appropriate lancet parameters (gauge and depth) to minimize hemolysis in capillary blood samples must be found to minimize falsely elevated readings. Third, device portability and ease of use must be evaluated using patient input, as these factors will affect patient compliance. We have validated the use of portable ISE technology to feasibly measure potassium, and we continue to collect data for our second and third tests.</p>","PeriodicalId":21679,"journal":{"name":"Scientia Horticulturae","volume":"178 1","pages":""},"PeriodicalIF":4.2000,"publicationDate":"2020-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8895231/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scientia Horticulturae","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1115/dmd2020-9066","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/7/27 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"HORTICULTURE","Score":null,"Total":0}
引用次数: 0

Abstract

Approximately 500,000 dialysis patients in America are at a high risk of hyperkalemia, a condition where blood potassium becomes elevated above normal levels. Hyperkalemia is extremely dangerous, as it can result in severe cardiac complications if untreated. Hyperkalemia may be silent or present vague symptoms until those complications develop, at which point patients require emergency medical care. However, if patients have the ability to measure their potassium levels at home, they could detect hyperkalemia before it reaches a dangerous stage, and seek preventative medical care to avoid severe complications. Therefore, we have designed a novel device allowing patients to measure their blood potassium levels at home. The workflow of our solution is as follows: (1) patients obtain a blood sample from a finger prick, (2) potassium concentration is measured with an ion specific electrode (ISE), and (3) the device displays their potassium levels and a recommended course of action based on their hyperkalemic risk. We validate our solution with three major tests. First, our portable ISE technology must accurately measure potassium concentration in blood samples. Second, appropriate lancet parameters (gauge and depth) to minimize hemolysis in capillary blood samples must be found to minimize falsely elevated readings. Third, device portability and ease of use must be evaluated using patient input, as these factors will affect patient compliance. We have validated the use of portable ISE technology to feasibly measure potassium, and we continue to collect data for our second and third tests.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
为透析患者开发便携式血钾监测设备。
美国约有 50 万名透析患者面临高钾血症的高风险,高钾血症是指血钾升高超过正常水平。高钾血症非常危险,如果不及时治疗,会导致严重的心脏并发症。在并发症出现之前,高钾血症可能无声无息或症状模糊,此时患者需要紧急医疗护理。但是,如果患者能够在家中测量自己的血钾水平,他们就能在高钾血症发展到危险阶段之前发现它,并寻求预防性医疗护理以避免严重并发症。因此,我们设计了一种新颖的设备,让患者可以在家测量血钾水平。我们的解决方案的工作流程如下:(1) 患者通过刺破手指获取血液样本;(2) 使用离子特异性电极(ISE)测量血钾浓度;(3) 设备显示血钾水平,并根据高血钾风险建议采取的行动。我们通过三项主要测试来验证我们的解决方案。首先,我们的便携式 ISE 技术必须准确测量血液样本中的钾浓度。其次,必须找到合适的柳叶刀参数(规格和深度),以最大限度地减少毛细血管血样中的溶血现象,从而最大限度地降低假性升高读数。第三,必须根据患者的意见对设备的便携性和易用性进行评估,因为这些因素会影响患者的依从性。我们已经验证了使用便携式 ISE 技术测量血钾的可行性,并将继续收集第二次和第三次测试的数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Scientia Horticulturae
Scientia Horticulturae 农林科学-园艺
CiteScore
8.60
自引率
4.70%
发文量
796
审稿时长
47 days
期刊介绍: Scientia Horticulturae is an international journal publishing research related to horticultural crops. Articles in the journal deal with open or protected production of vegetables, fruits, edible fungi and ornamentals under temperate, subtropical and tropical conditions. Papers in related areas (biochemistry, micropropagation, soil science, plant breeding, plant physiology, phytopathology, etc.) are considered, if they contain information of direct significance to horticulture. Papers on the technical aspects of horticulture (engineering, crop processing, storage, transport etc.) are accepted for publication only if they relate directly to the living product. In the case of plantation crops, those yielding a product that may be used fresh (e.g. tropical vegetables, citrus, bananas, and other fruits) will be considered, while those papers describing the processing of the product (e.g. rubber, tobacco, and quinine) will not. The scope of the journal includes all horticultural crops but does not include speciality crops such as, medicinal crops or forestry crops, such as bamboo. Basic molecular studies without any direct application in horticulture will not be considered for this journal.
期刊最新文献
Malic acid modulates adventitious root elongation through auxin accumulation and MdTCP17-mediated regulation in apple Genome-wide identification and functional analysis of UGT genes reveal multiple flavonoid 3-O-glycosyltransferases synergistically enhancing cold tolerance in Allium fistulosum Comprehensive genomic identification and expression analysis of the U-box gene family and its association with pigment biosynthesis in pepper (Capsicum annuum L.) Genome-wide identification of CKX genes in petunia reveals PhCKX3 as a key regulator of flower and leaf development Differentiation of volatile organic compounds and sensory characteristics in the upper and lower flowers of grape hyacinth
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1