{"title":"Study on the optimization of radiation protection for therapeutic proton synchrotron","authors":"Weiguo Zhu, Jing Liang, Chang-song Hou, Dexing Lian, Zhen Zhang","doi":"10.3760/CMA.J.ISSN.0254-5098.2019.09.013","DOIUrl":null,"url":null,"abstract":"Objective \nTo investigate the effect of iron shield at different depths within main protection wall on the dose rate outside the protection wall. \n \n \nMethods \nBy adopting the FLUKA code, a therapeutic room model was constructed with its primary protective barrier consisting of concrete and iron. In order to obtain its ambient dose equivalent rate distribution, the 250 MeV protons and 220 MeV protons impinging on water phantom were simulated separately. \n \n \nResults \nWith varying depth of iron plate embedded in barrier, the ambient dose equivalent rates in the two simulated conditions differed sinificantly at 30 cm outside the protection wall. The maximum ambient dose equivalent rate(220 MeV: 3.42 μSv/h, 250 MeV: 6.39 μSv/h) was more than 2 times higher than the minimum ambient dose equivalent rate(220 MeV: 1.75 μSv/h, 250 MeV: 3.32 μSv/h). \n \n \nConclusions \nIn the design of therapeutic proton accelerator, it is essential to evaluate carefully the location where the iron shield is in main protection wall. \n \n \nKey words: \nMonte Carlo simulation; Therapeutic proton accelerator; Barrier; Ambient dose equivalent rate","PeriodicalId":36403,"journal":{"name":"中华放射医学与防护杂志","volume":"271 1","pages":"707-710"},"PeriodicalIF":0.0000,"publicationDate":"2019-09-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华放射医学与防护杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.0254-5098.2019.09.013","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 2

Abstract

Objective To investigate the effect of iron shield at different depths within main protection wall on the dose rate outside the protection wall. Methods By adopting the FLUKA code, a therapeutic room model was constructed with its primary protective barrier consisting of concrete and iron. In order to obtain its ambient dose equivalent rate distribution, the 250 MeV protons and 220 MeV protons impinging on water phantom were simulated separately. Results With varying depth of iron plate embedded in barrier, the ambient dose equivalent rates in the two simulated conditions differed sinificantly at 30 cm outside the protection wall. The maximum ambient dose equivalent rate(220 MeV: 3.42 μSv/h, 250 MeV: 6.39 μSv/h) was more than 2 times higher than the minimum ambient dose equivalent rate(220 MeV: 1.75 μSv/h, 250 MeV: 3.32 μSv/h). Conclusions In the design of therapeutic proton accelerator, it is essential to evaluate carefully the location where the iron shield is in main protection wall. Key words: Monte Carlo simulation; Therapeutic proton accelerator; Barrier; Ambient dose equivalent rate
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
治疗性质子同步加速器辐射防护优化研究
目的探讨主防护墙内不同深度的铁屏蔽对防护墙外剂量率的影响。方法采用FLUKA规范,以混凝土和铁为主要防护屏障,构建治疗室模型。为了得到水影的环境剂量当量率分布,分别模拟了250 MeV和220 MeV质子撞击水影的情况。结果不同铁板埋置深度下,在防护墙外30cm处,两种模拟条件下的环境剂量当量率差异显著。最大环境剂量当量率(220 MeV: 3.42 μSv/h, 250 MeV: 6.39 μSv/h)比最小环境剂量当量率(220 MeV: 1.75 μSv/h, 250 MeV: 3.32 μSv/h)高2倍以上。结论在治疗性质子加速器的设计中,应仔细评估铁屏蔽在主防护壁的位置。关键词:蒙特卡罗模拟;治疗性质子加速器;屏障;环境剂量当量率
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
中华放射医学与防护杂志
中华放射医学与防护杂志 Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
0.60
自引率
0.00%
发文量
6377
期刊介绍:
期刊最新文献
Infection control status of novel coronavirus pneumonia and radiation safety at CT workplace Current status of the application of radiodiagnosis and radiotherapy resources in Huai'an City in 2020 The application value of low-dose CT scan in pregnant women with COVID-19 Eeffects of tube voltage on image quality and radiation dose of paranasal sinus CT examination Analyzing quality of life and influencing factors in patients with bone metastasis of hepatocellular carcinoma before and after radiotherapy by bone pain scale
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1