Simultaneous Determination of Aluminium and Iron with Hematoxylin Using Spectrophotometric and Orthogonal Signal Correction-Partial Least Squares in Plant and Water

Ali Niazi, Javad Zolgharnein, Mohammad Reza Davoodabadi
{"title":"Simultaneous Determination of Aluminium and Iron with Hematoxylin Using Spectrophotometric and Orthogonal Signal Correction-Partial Least Squares in Plant and Water","authors":"Ali Niazi,&nbsp;Javad Zolgharnein,&nbsp;Mohammad Reza Davoodabadi","doi":"10.1002/adic.200790104","DOIUrl":null,"url":null,"abstract":"<p>Simple and novel spectrophotometric method is described for simultaneous determination of aluminum and iron. The method is based on the colored complexes formed by aluminum and iron with hematoxylin in the presence of cetyltrimethylammonium bromide as a surfactant at pH 5.8. All factors affecting the sensitivity were optimized and the linear dynamic range for determination of aluminum and iron was found. The simultaneous determination of aluminum and iron mixtures by using spectrophotometric methods is a difficult problem, due to spectral interferences. By multivariate calibration methods such as partial least squares (PLS), it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Orthogonal signal correction (OSC) is a preprocessing technique used for removing the unrelated information and is a suitable preprocessing method for PLS calibration of mixtures without loss of prediction capacity using spectrophotometric method. In this study, the calibration model is based on absorption spectra in the 360-620 nm range for 25 different mixtures of aluminum and iron. Calibration matrices contained 0.06-21.00 and 0.03-15.00 μg mL<sup>-1</sup> of aluminum and iron, respectively. The RMSEP for aluminum and iron with OSC and without OSC were 0.06, 0.08 and 0.24, 0.27, respectively. The proposed method has been applied to the simultaneous determination of aluminum and iron in plant and water samples.</p>","PeriodicalId":8193,"journal":{"name":"Annali di chimica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2007-11-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/adic.200790104","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annali di chimica","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/adic.200790104","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

Abstract

Simple and novel spectrophotometric method is described for simultaneous determination of aluminum and iron. The method is based on the colored complexes formed by aluminum and iron with hematoxylin in the presence of cetyltrimethylammonium bromide as a surfactant at pH 5.8. All factors affecting the sensitivity were optimized and the linear dynamic range for determination of aluminum and iron was found. The simultaneous determination of aluminum and iron mixtures by using spectrophotometric methods is a difficult problem, due to spectral interferences. By multivariate calibration methods such as partial least squares (PLS), it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Orthogonal signal correction (OSC) is a preprocessing technique used for removing the unrelated information and is a suitable preprocessing method for PLS calibration of mixtures without loss of prediction capacity using spectrophotometric method. In this study, the calibration model is based on absorption spectra in the 360-620 nm range for 25 different mixtures of aluminum and iron. Calibration matrices contained 0.06-21.00 and 0.03-15.00 μg mL-1 of aluminum and iron, respectively. The RMSEP for aluminum and iron with OSC and without OSC were 0.06, 0.08 and 0.24, 0.27, respectively. The proposed method has been applied to the simultaneous determination of aluminum and iron in plant and water samples.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
苏木精分光光度法-正交信号校正-偏最小二乘同时测定植物和水中的铝和铁
介绍了一种简便、新颖的同时测定铝和铁的分光光度法。该方法是基于铝和铁与苏木精在pH为5.8的十六烷基三甲基溴化铵作为表面活性剂存在下形成的有色配合物。对影响灵敏度的各因素进行了优化,确定了测定铝和铁的线性动态范围。由于光谱干扰,用分光光度法同时测定铝和铁混合物是一个难题。通过偏最小二乘(PLS)等多变量校准方法,可以获得一个调整到校准范围内所用混合物浓度值的模型。正交信号校正(OSC)是一种去除不相关信息的预处理技术,是分光光度法在不损失预测能力的情况下校准混合物PLS的一种合适的预处理方法。在本研究中,校准模型基于25种不同铝和铁混合物在360-620 nm范围内的吸收光谱。校正矩阵中铝和铁的含量分别为0.06 ~ 21.00和0.03 ~ 15.00 μ mL-1。含盐和不含盐的铝和铁的RMSEP分别为0.06、0.08和0.24、0.27。该方法已应用于植物和水样中铝和铁的同时测定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of Solid Phase Microextraction-High Performance Liquid Chromatographic Method for the Determination of Copper(II) in Environmental Samples Using Morpholine-4-Carbodithioate Flotation Separation and Flame Atomic Absorption Spectrometric Determination of Trace Amount of Lead in Some Environmental Samples Investigation of Distribution of Heavy Metals between Blood Plasma and Blood Cells Kinetic-Catalytic and Spectrophotometric Determination of Hg(II) Using its Catalytic Effect on Ligand Substitution Reaction between Hexacyanoferrate(II) and Pyrazine PVC Matrix Membrane Sensor for Potentiometric Determination of Triphenyltetrazolium Chloride and Ascorbic Acid
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1