{"title":"Study on the implementation of flow titrations in sequential injection analysis","authors":"J. M. Estela, F. Mas, A. Cladera, V. Cerdà","doi":"10.1002/(SICI)1098-2728(1999)11:4<207::AID-LRA5>3.0.CO;2-G","DOIUrl":null,"url":null,"abstract":"<p>Several variables that affect flow spectrophotometric titrations in sequential injection analysis (SIA) systems were studied by using titration of a strong acid with a strong base as a model; blue bromothymol was used as an indicator and distilled water was used as a carrier. Both possibilities of performing titrations on SIA systems according to the aspiration sequences (a) titrant B/sample/titrant A and (b) titrant/sample are considered. In case (a) the possibilities regarding the use of different volumes and/or different concentrations of titrant reagents were studied and are discussed. The established methodology allows hydrochloric acid determinations with 0.1 M sodium hydroxide within the range 32–1000 mM by means of logarithmic calibration curves. The analysis rate is of 5 min/sample. © 1999 John Wiley & Sons, Inc. Lab Robotics and Automation 11: 207–216, 1999</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"11 4","pages":"207-216"},"PeriodicalIF":0.0000,"publicationDate":"1999-08-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(1999)11:4<207::AID-LRA5>3.0.CO;2-G","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Robotics and Automation","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291098-2728%281999%2911%3A4%3C207%3A%3AAID-LRA5%3E3.0.CO%3B2-G","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4
Abstract
Several variables that affect flow spectrophotometric titrations in sequential injection analysis (SIA) systems were studied by using titration of a strong acid with a strong base as a model; blue bromothymol was used as an indicator and distilled water was used as a carrier. Both possibilities of performing titrations on SIA systems according to the aspiration sequences (a) titrant B/sample/titrant A and (b) titrant/sample are considered. In case (a) the possibilities regarding the use of different volumes and/or different concentrations of titrant reagents were studied and are discussed. The established methodology allows hydrochloric acid determinations with 0.1 M sodium hydroxide within the range 32–1000 mM by means of logarithmic calibration curves. The analysis rate is of 5 min/sample. © 1999 John Wiley & Sons, Inc. Lab Robotics and Automation 11: 207–216, 1999
流动滴定法在序贯注射分析中的应用研究
以强酸与强碱滴定为模型,研究了影响序贯注射分析(SIA)系统中流动分光光度滴定的几个变量;以蓝色溴百里酚为指示剂,蒸馏水为载体。考虑了在SIA系统上根据抽吸顺序(a)滴定剂B/样品/滴定剂a和(B)滴定剂/样品进行滴定的两种可能性。在(a)情况下,对使用不同体积和/或不同浓度的滴定试剂的可能性进行了研究和讨论。所建立的方法允许用0.1 M氢氧化钠在32-1000 mM范围内通过对数校准曲线进行盐酸测定。分析速度为5分钟/个样品。©1999 John Wiley &儿子,Inc。机械工程学报(自然科学版),2009
本文章由计算机程序翻译,如有差异,请以英文原文为准。