Determination of trace amounts of copper using a flow-through spectrophotometric sensor

J. M. Colsa Herrera, F. Sanchez Rojas, C. Bosch Ojeda, A. García de Torres, J. M. Cano Pavón
{"title":"Determination of trace amounts of copper using a flow-through spectrophotometric sensor","authors":"J. M. Colsa Herrera,&nbsp;F. Sanchez Rojas,&nbsp;C. Bosch Ojeda,&nbsp;A. García de Torres,&nbsp;J. M. Cano Pavón","doi":"10.1002/1098-2728(2000)12:5<241::AID-LRA4>3.0.CO;2-W","DOIUrl":null,"url":null,"abstract":"<p>A flow-through spectrophotometric sensor for determination of copper based on retention of Cu(I)-1,2 ciclohexanedione thiosemicarbazone complex on C<sub>18</sub> bonded phase beads packed in a flow-cell was developed. The method is highly selective for copper; it features a detection limit of 50 ng mL<sup>−1</sup> and a linear range from at least 0.1 to 10 μg mL<sup>−1</sup>. The method is subject to very few interferences and is more sensitive than the batch procedure. The proposed method was applied to the determination of copper in catalysts and alloys. © 2000 John Wiley &amp; Sons, Inc. Lab Robotics and Automation 12:241–245, 2000</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"12 5","pages":"241-245"},"PeriodicalIF":0.0000,"publicationDate":"2000-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/1098-2728(2000)12:5<241::AID-LRA4>3.0.CO;2-W","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Robotics and Automation","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/1098-2728%282000%2912%3A5%3C241%3A%3AAID-LRA4%3E3.0.CO%3B2-W","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

Abstract

A flow-through spectrophotometric sensor for determination of copper based on retention of Cu(I)-1,2 ciclohexanedione thiosemicarbazone complex on C18 bonded phase beads packed in a flow-cell was developed. The method is highly selective for copper; it features a detection limit of 50 ng mL−1 and a linear range from at least 0.1 to 10 μg mL−1. The method is subject to very few interferences and is more sensitive than the batch procedure. The proposed method was applied to the determination of copper in catalysts and alloys. © 2000 John Wiley & Sons, Inc. Lab Robotics and Automation 12:241–245, 2000

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用流动分光光度传感器测定痕量铜
建立了一种基于Cu(I)-1,2环己二酮硫代氨基脲配合物在流动池中C18键合相珠上的保留量测定铜的流动分光光度传感器。该方法对铜有很高的选择性;其检测限为50 ng mL - 1,线性范围至少为0.1至10 μg mL - 1。该方法受干扰很小,比批处理法更灵敏。该方法可用于催化剂和合金中铜的测定。©2000 John Wiley &儿子,Inc。实验室机器人与自动化,2000:241 - 245
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Flow system for calibration and interference examination in two-component analysis Development of hardware and software for on-line sample preparation using sequential-injection analysis Automation of procedures to measure ash content for polyolefin and ryton poly(phenylene sulfide) resins Spectrophotometric determination of phosphite in fertilizers in a flow injection system with online sample preparation Determination of trace amounts of copper using a flow-through spectrophotometric sensor
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1