A 280μW dynamic-zoom ADC with 120dB DR and 118dB SNDR in 1kHz BW

Shoubhik Karmakar, B. Gonen, F. Sebastiano, R. V. Veldhoven, K. Makinwa
{"title":"A 280μW dynamic-zoom ADC with 120dB DR and 118dB SNDR in 1kHz BW","authors":"Shoubhik Karmakar, B. Gonen, F. Sebastiano, R. V. Veldhoven, K. Makinwa","doi":"10.1109/ISSCC.2018.8310272","DOIUrl":null,"url":null,"abstract":"Micro-power ADCs with high linearity and dynamic range (DR) are required in several applications, such as smart sensors, biomedical imaging, and portable instrumentation. Since the signals of interest are then often small (tens of μν) and slow (<1kHz BW), such ADCs should also exhibit low offset and flicker noise. Noise-shaping SAR [1] and incremental ADCs [2] have been proposed for such applications, but their DR is limited to about 100dB. Although the ΔΣ modulator (ΔΣM) proposed in [3] achieves 136dB DR, it is at the expense of high power consumption (12.7mW). The incremental zoom ADC proposed in [4] combines a coarse SAR ADC and a fine ΔΣ ADC to efficiently achieve 119.8dB DR, but is limited to DC signals. The dynamic zoom ADC in [5] solves this problem, but requires external filtering to cope with out-of-band interference. This paper describes an interferer-robust dynamic zoom ADC that consumes 280μW while achieving 120.3dB DR and 118.1dB SNDR in 1kHz BW, resulting in a Schreier FoM of 185.8dB. It also achieves a maximum offset of 30μν and a 1/f corner of 7Hz. These advances are achieved by the combination of dynamic error-correction techniques, an asynchronous SAR ADC and a fully differential inverter-based ΔΣ ADC.","PeriodicalId":6617,"journal":{"name":"2018 IEEE International Solid - State Circuits Conference - (ISSCC)","volume":"49 1","pages":"238-240"},"PeriodicalIF":0.0000,"publicationDate":"2018-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE International Solid - State Circuits Conference - (ISSCC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISSCC.2018.8310272","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

Abstract

Micro-power ADCs with high linearity and dynamic range (DR) are required in several applications, such as smart sensors, biomedical imaging, and portable instrumentation. Since the signals of interest are then often small (tens of μν) and slow (<1kHz BW), such ADCs should also exhibit low offset and flicker noise. Noise-shaping SAR [1] and incremental ADCs [2] have been proposed for such applications, but their DR is limited to about 100dB. Although the ΔΣ modulator (ΔΣM) proposed in [3] achieves 136dB DR, it is at the expense of high power consumption (12.7mW). The incremental zoom ADC proposed in [4] combines a coarse SAR ADC and a fine ΔΣ ADC to efficiently achieve 119.8dB DR, but is limited to DC signals. The dynamic zoom ADC in [5] solves this problem, but requires external filtering to cope with out-of-band interference. This paper describes an interferer-robust dynamic zoom ADC that consumes 280μW while achieving 120.3dB DR and 118.1dB SNDR in 1kHz BW, resulting in a Schreier FoM of 185.8dB. It also achieves a maximum offset of 30μν and a 1/f corner of 7Hz. These advances are achieved by the combination of dynamic error-correction techniques, an asynchronous SAR ADC and a fully differential inverter-based ΔΣ ADC.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
280μW动态变焦ADC, 1kHz时DR为120dB, SNDR为118dB
具有高线性度和高动态范围(DR)的微功率adc在智能传感器、生物医学成像和便携式仪器等多个应用中都是必需的。由于感兴趣的信号通常很小(几十μν)且速度慢(<1kHz BW),因此此类adc还应表现出低偏移和闪烁噪声。噪声整形SAR[1]和增量adc[2]已被提出用于此类应用,但它们的DR限制在100dB左右。虽然[3]中提出的ΔΣ调制器(ΔΣM)实现了136dB DR,但代价是高功耗(12.7mW)。[4]中提出的增量变焦ADC结合了粗糙SAR ADC和精细ΔΣ ADC,可有效实现119.8dB DR,但仅限于DC信号。[5]中的动态变焦ADC解决了这一问题,但需要外部滤波来应对带外干扰。本文介绍了一种抗干扰动态变焦ADC,该ADC功耗为280μW,在1kHz BW下可实现120.3dB的DR和118.1dB的SNDR, Schreier FoM为185.8dB。它还实现了30μν的最大偏移和7Hz的1/f角。这些进步是通过结合动态纠错技术、异步SAR ADC和基于全差分逆变器的ΔΣ ADC实现的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
EE1: Student research preview (SRP) A 512Gb 3b/Cell 3D flash memory on a 96-word-line-layer technology Single-chip reduced-wire active catheter system with programmable transmit beamforming and receive time-division multiplexing for intracardiac echocardiography A 2.5nJ duty-cycled bridge-to-digital converter integrated in a 13mm3 pressure-sensing system A 36.3-to-38.2GHz −216dBc/Hz2 40nm CMOS fractional-N FMCW chirp synthesizer PLL with a continuous-time bandpass delta-sigma time-to-digital converter
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1