Measuring Residual Magnetic Field in the Magnetic Shield with Magnetic Resonance Signal Width

Yucheng Yang, Jingbiao Chen, Xiang Peng, Teng Wu, Hong Guo
{"title":"Measuring Residual Magnetic Field in the Magnetic Shield with Magnetic Resonance Signal Width","authors":"Yucheng Yang, Jingbiao Chen, Xiang Peng, Teng Wu, Hong Guo","doi":"10.1109/IFCS-ISAF41089.2020.9234902","DOIUrl":null,"url":null,"abstract":"In this article, we present a novel method to measure the residual magnetic field in the magnetic shield. Because of the nonlinear Zeeman effect, the magnetic resonance width will grow with the increasing magnetic field. By detecting the dependence of the magnetic resonance signal width on the applied magnetic field, the residual magnetic field in the magnetic shield can be deduced. The error of the deduced value and the true value can be less than 1.5 nT. Higher sampling rate can result in less error.","PeriodicalId":6872,"journal":{"name":"2020 Joint Conference of the IEEE International Frequency Control Symposium and International Symposium on Applications of Ferroelectrics (IFCS-ISAF)","volume":"30 1","pages":"1-2"},"PeriodicalIF":0.0000,"publicationDate":"2020-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 Joint Conference of the IEEE International Frequency Control Symposium and International Symposium on Applications of Ferroelectrics (IFCS-ISAF)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IFCS-ISAF41089.2020.9234902","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In this article, we present a novel method to measure the residual magnetic field in the magnetic shield. Because of the nonlinear Zeeman effect, the magnetic resonance width will grow with the increasing magnetic field. By detecting the dependence of the magnetic resonance signal width on the applied magnetic field, the residual magnetic field in the magnetic shield can be deduced. The error of the deduced value and the true value can be less than 1.5 nT. Higher sampling rate can result in less error.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用磁共振信号宽度测量磁屏蔽内残余磁场
本文提出了一种测量磁屏蔽中残余磁场的新方法。由于非线性塞曼效应,共振宽度随磁场的增大而增大。通过检测磁共振信号宽度与外加磁场的关系,可以推导出磁屏蔽内的剩余磁场。推导值与真实值的误差可以小于1.5 nT,提高采样率可以减小误差。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Ferroelectric Capacitor based Adaptive Differential Equalizer Sensitivity Enhancement in Resonant Microbolometers with Dual Mode Operation Periodic Poling of X-Cut Thin-Film Lithium Niobate: The Route to Submicrometer Periods Enabling Channelizing Filters for High Impedance Nodes with Temperature Compensated Lamb-Wave Resonators Characterization of a Static Magnetic Field with Two-Photon Rotational Spectroscopy of Cold Trapped HD+
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1