Shear Strength Evaluation of Directly and Indirectly Loaded Rectangular Recycled Self-Compacted Reinforced Concrete Slender Beams Using Experimental and Finite Element Analysis

T. Alhussein, Jamal Abdul Samad, Khudhair
{"title":"Shear Strength Evaluation of Directly and Indirectly Loaded Rectangular Recycled Self-Compacted Reinforced Concrete Slender Beams Using Experimental and Finite Element Analysis","authors":"T. Alhussein, Jamal Abdul Samad, Khudhair","doi":"10.32792/utq/utj/vol15/2/4","DOIUrl":null,"url":null,"abstract":"This study presents an experimental and numerical evaluation of the shear behavior of recycled aggregate concrete beams without transversal reinforcement. These beams were manufactured as self-compacted concrete with the use of both natural aggregate and recycled aggregate. The beams were subjected to direct and indirect loading conditions. The mechanical properties of four mixes were characterized in terms of compressive strength, splitting tensile strength, and elastic modulus. The experimental results showed that the shear capacity of recycled aggregate concrete is lower than those made with natural aggregate. The experimental shear capacities of the tested beams were compared with ACI318M-14 and relevant research studies in the literature. The ratio of experimental shear stress divided by the root square of concrete compressive strength (𝑣𝑒𝑥𝑝/ √𝑓𝑐`) , which indicates the ability of diagonally cracked concrete to transmit tension and shear. was remained for all configurations greater than 0.17, which is the minimum value recommended by the ACI318-14. Results from nonlinear finite element models were compared with the experimental data, and good agreement was achieved.","PeriodicalId":23465,"journal":{"name":"University of Thi-Qar Journal","volume":"107 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"University of Thi-Qar Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.32792/utq/utj/vol15/2/4","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

This study presents an experimental and numerical evaluation of the shear behavior of recycled aggregate concrete beams without transversal reinforcement. These beams were manufactured as self-compacted concrete with the use of both natural aggregate and recycled aggregate. The beams were subjected to direct and indirect loading conditions. The mechanical properties of four mixes were characterized in terms of compressive strength, splitting tensile strength, and elastic modulus. The experimental results showed that the shear capacity of recycled aggregate concrete is lower than those made with natural aggregate. The experimental shear capacities of the tested beams were compared with ACI318M-14 and relevant research studies in the literature. The ratio of experimental shear stress divided by the root square of concrete compressive strength (𝑣𝑒𝑥𝑝/ √𝑓𝑐`) , which indicates the ability of diagonally cracked concrete to transmit tension and shear. was remained for all configurations greater than 0.17, which is the minimum value recommended by the ACI318-14. Results from nonlinear finite element models were compared with the experimental data, and good agreement was achieved.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用试验和有限元分析评价直接和间接加载的矩形自密实钢筋混凝土细长梁的抗剪强度
本文对无横向配筋再生骨料混凝土梁的抗剪性能进行了试验和数值评价。这些梁是用天然骨料和再生骨料制成的自密实混凝土。梁受到直接和间接加载条件。从抗压强度、劈裂抗拉强度和弹性模量等方面对四种混合料的力学性能进行了表征。试验结果表明,再生骨料混凝土的抗剪能力低于天然骨料混凝土。将试验梁的抗剪承载力与ACI318M-14及文献相关研究进行对比。试验剪应力除以混凝土抗压强度平方根(𝑣𝑒≥𝑝/√𝑓𝑐’)的比值,表示对角开裂混凝土传递拉剪的能力。所有大于0.17的配置都保留,这是ac318 -14推荐的最小值。将非线性有限元模型计算结果与实验数据进行了比较,结果吻合较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Shear Strength Evaluation of Directly and Indirectly Loaded Rectangular Recycled Self-Compacted Reinforced Concrete Slender Beams Using Experimental and Finite Element Analysis Study of Some Hematological Parameters in Offpring of Heperlipidemic Female Laboratory Rats After Slmvastatln Treatment During Lactation. Study of Some Hematological Parameters in Offpring of Heperlipidemic Female Laboratory Rats After Slmvastatln Treatment During Lactation Preparation and Characterization of New Ligand Azo-Schiff-2- Naphthol and Mixed Complexes With Ortho- Aminophenol and Ortho-Aminobenzoic Acid. Selected Antenatal Health Care Parameters of Pregnant Women’s in Duhok Province, Iraq.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1