Results from a Prototype Proton-CT Head Scanner

R.P. Johnson , V.A. Bashkirov , G. Coutrakon , V. Giacometti , P. Karbasi , N.T. Karonis , C.E. Ordoñez , M. Pankuch , H.F.-W. Sadrozinski , K.E. Schubert , R.W. Schulte
{"title":"Results from a Prototype Proton-CT Head Scanner","authors":"R.P. Johnson ,&nbsp;V.A. Bashkirov ,&nbsp;G. Coutrakon ,&nbsp;V. Giacometti ,&nbsp;P. Karbasi ,&nbsp;N.T. Karonis ,&nbsp;C.E. Ordoñez ,&nbsp;M. Pankuch ,&nbsp;H.F.-W. Sadrozinski ,&nbsp;K.E. Schubert ,&nbsp;R.W. Schulte","doi":"10.1016/j.phpro.2017.09.060","DOIUrl":null,"url":null,"abstract":"<div><p>We are exploring low-dose proton radiography and computed tomography (pCT) as techniques to improve the accuracy of proton treatment planning and to provide artifact-free images for verification and adaptive therapy at the time of treatment. Here we report on comprehensive beam test results with our prototype pCT head scanner. The detector system and data acquisition attain a sustained rate of more than a million protons individually measured per second, allowing a full CT scan to be completed in six minutes or less of beam time. In order to assess the performance of the scanner for proton radiography as well as computed tomography, we have performed numerous scans of phantoms at the Northwestern Medicine Chicago Proton Center including a custom phantom designed to assess the spatial resolution, a phantom to assess the measurement of relative stopping power, and a dosimetry phantom. Some images, performance, and dosimetry results from those phantom scans are presented together with a description of the instrument, the data acquisition system, and the calibration methods.</p></div>","PeriodicalId":20407,"journal":{"name":"Physics Procedia","volume":"90 ","pages":"Pages 209-214"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.phpro.2017.09.060","citationCount":"23","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Physics Procedia","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1875389217302195","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 23

Abstract

We are exploring low-dose proton radiography and computed tomography (pCT) as techniques to improve the accuracy of proton treatment planning and to provide artifact-free images for verification and adaptive therapy at the time of treatment. Here we report on comprehensive beam test results with our prototype pCT head scanner. The detector system and data acquisition attain a sustained rate of more than a million protons individually measured per second, allowing a full CT scan to be completed in six minutes or less of beam time. In order to assess the performance of the scanner for proton radiography as well as computed tomography, we have performed numerous scans of phantoms at the Northwestern Medicine Chicago Proton Center including a custom phantom designed to assess the spatial resolution, a phantom to assess the measurement of relative stopping power, and a dosimetry phantom. Some images, performance, and dosimetry results from those phantom scans are presented together with a description of the instrument, the data acquisition system, and the calibration methods.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
原型质子ct头部扫描仪的结果
我们正在探索低剂量质子放射照相和计算机断层扫描(pCT)技术,以提高质子治疗计划的准确性,并在治疗时提供无伪影的图像以进行验证和适应性治疗。在这里,我们报告了我们的原型pCT头部扫描仪的综合光束测试结果。探测器系统和数据采集实现了每秒测量超过一百万个质子的持续速率,允许在6分钟或更短的光束时间内完成一次完整的CT扫描。为了评估质子放射成像和计算机断层扫描扫描仪的性能,我们在西北医学芝加哥质子中心对幻影进行了多次扫描,包括用于评估空间分辨率的定制幻影、用于评估相对停止功率测量的幻影和剂量测定幻影。一些图像,性能和剂量学的结果,从这些幻影扫描与描述仪器,数据采集系统和校准方法一起提出。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Dynamic and absolute measurements of laser coupling efficiency during laser spot welds Time-Resolved Detection of Vaporization during Laser Metal Processing with Laser-induced Fluorescence Preface Editorial Contents
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1