THE UTILITY OF POLYSOMNOGRAPHY(PSG) MACHINE AS A RELIABLE LIE DETECTOR IN AN EXPERIMENTALLY INDUCED MOCK THEFT SITUATION

Ajagallay Rajesh Kumar, Janghel Gaukaran, Bhagat Vimal Chandra
{"title":"THE UTILITY OF POLYSOMNOGRAPHY(PSG) MACHINE AS A RELIABLE LIE DETECTOR IN AN EXPERIMENTALLY INDUCED MOCK THEFT SITUATION","authors":"Ajagallay Rajesh Kumar, Janghel Gaukaran, Bhagat Vimal Chandra","doi":"10.15520/IJMHS.V10I12.3174","DOIUrl":null,"url":null,"abstract":"Objective- To compare the various parameters in polysomnographic recordings of individuals who had indulged in experimentally induced theft situation with subjects who had not indulged in an experimentally induced theft situation. \nMaterial and methods-The present study was conducted in the department of psychiatry, Sarojini Naidu Medical College (S.N.M.C.) Agra, between the periods, March 2010 and September 2011. The sample consisted of 102 medical students who had volunteered to participate in the study.  These volunteers were selected on the following criteria's. \nResult- The present study finding shows statistically  significant difference on EEG amplitude, there are C3-A2 lead EEG amplitude were significant in group A and group C (control versus stolen, at baseline p-value = 0.0001; after 10th minute p-value = 0.0007; and after 20th minute p-value = 0.0129); EEG amplitude in O1-A2 lead were significant in control and stolen group ( at baseline p-value = 0.0019 and after 10th minute p-value = 0.0505); EEG amplitude in O2-A1 lead were found significant in control versus stolen group ( at baseline p-value = 0.0002, after 10th minute p-value = 0.0347, and 20th minute p-value = 0.0262). \nConclusion- The changes observed in the amplitude of C3-A2 and O2-A1 leads along with C4-A1 (mv), O1-A2 (mv) leads could better identify the subjects who had stolen money, due to higher apprehension created for being caught during their PSG recordings while other leads which did not show significant changes in the PSG recordings could be considered as being not affected during deception. \nKeyword-    Polysomnography, Amplitude, Lie Detection","PeriodicalId":13590,"journal":{"name":"Innovative Journal of Medical and Health Science","volume":"241 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Innovative Journal of Medical and Health Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15520/IJMHS.V10I12.3174","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective- To compare the various parameters in polysomnographic recordings of individuals who had indulged in experimentally induced theft situation with subjects who had not indulged in an experimentally induced theft situation. Material and methods-The present study was conducted in the department of psychiatry, Sarojini Naidu Medical College (S.N.M.C.) Agra, between the periods, March 2010 and September 2011. The sample consisted of 102 medical students who had volunteered to participate in the study.  These volunteers were selected on the following criteria's. Result- The present study finding shows statistically  significant difference on EEG amplitude, there are C3-A2 lead EEG amplitude were significant in group A and group C (control versus stolen, at baseline p-value = 0.0001; after 10th minute p-value = 0.0007; and after 20th minute p-value = 0.0129); EEG amplitude in O1-A2 lead were significant in control and stolen group ( at baseline p-value = 0.0019 and after 10th minute p-value = 0.0505); EEG amplitude in O2-A1 lead were found significant in control versus stolen group ( at baseline p-value = 0.0002, after 10th minute p-value = 0.0347, and 20th minute p-value = 0.0262). Conclusion- The changes observed in the amplitude of C3-A2 and O2-A1 leads along with C4-A1 (mv), O1-A2 (mv) leads could better identify the subjects who had stolen money, due to higher apprehension created for being caught during their PSG recordings while other leads which did not show significant changes in the PSG recordings could be considered as being not affected during deception. Keyword-    Polysomnography, Amplitude, Lie Detection
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
多导睡眠描记仪(psg)在模拟盗窃实验中作为可靠测谎仪的应用
目的:比较实验诱发偷窃行为与非实验诱发偷窃行为的多导睡眠图记录的各项参数。材料和方法-本研究在Sarojini Naidu医学院(S.N.M.C.)精神科进行。阿格拉,2010年3月至2011年9月期间。样本由102名自愿参加研究的医学生组成。这些志愿者是根据以下标准选出的。结果:本研究结果显示脑电图幅值有统计学差异,A组和C组的C3-A2导联脑电图幅值有统计学意义(对照与被盗,基线p值= 0.0001;10分钟后p值= 0.0007;20分钟后p值= 0.0129);对照组和盗药组O1-A2导联波幅显著(基线时p值= 0.0019,10分钟后p值= 0.0505);对照组e2 - a1导联的脑电图波幅值与被盗组比较显著(基线时p值= 0.0002,第10分钟p值= 0.0347,第20分钟p值= 0.0262)。结论:C3-A2和O2-A1引线的振幅变化以及C4-A1 (mv)、01 - a2 (mv)引线的振幅变化可以更好地识别偷钱的受试者,因为在他们的PSG记录中产生了更高的被抓住的恐惧,而其他在PSG记录中没有显示显着变化的引线可以被认为在欺骗过程中没有受到影响。关键词:多导睡眠图,振幅,测谎
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Acute Neonatal Upper Limb Ischemia: Topical Vasodilation, Anticoagulation and Physical Therapy-A new option for complete reversal of ischemia Linezolid Induced Thrombocytopenia: A Case Report The Accuracy of Documented Nursing Care Plan among Registered Nurses CONTRADICTION TO CLINICAL IMMUNOLOGY. SUPPRESSION AND STIMULATION OF IMMUNE REACTIVITY IN PATHOLOGICAL PROCESSES Child and Adolescent Obesity in Saudi Arabia
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1