The simultaneous separation of twenty-one metal cations using capillary isotachophoresis with on-column conductivity detection

J. E. Prest, P. Fielden
{"title":"The simultaneous separation of twenty-one metal cations using capillary isotachophoresis with on-column conductivity detection","authors":"J. E. Prest, P. Fielden","doi":"10.1039/A905511H","DOIUrl":null,"url":null,"abstract":"The possibility of using capillary isotachophoresis coupled with on-column conductivity detection for the separation of complex metal cation mixtures has been demonstrated. The simultaneous separation of a mixture of the 21 metal cations Ca2+, Mg2+, Mn2+, Co2+, Ni2+, Zn2+, Be2+, La3+, Ce3+, Pr3+, Nd3+, Sm3+, Eu3+, Gd3+, Cu2+, Y3+, Ho3+, Er3+, Tm3+, Yb3+ and Lu3+ has been reproducibly achieved using aqueous electrolytes. Calibration curves were produced for two of these ions, Co2+ and Er3+. A linear response was observed over the range from 0.02 mmol dm–3 to 1.70 mmol dm–3 for cobalt and 0.05 mmol dm–3 to 1.00 mmol dm–3 for erbium. These curves allowed limits of detection to be calculated as 0.015 mmol dm–3 for cobalt and 0.045 mmol dm–3 for erbium.","PeriodicalId":7814,"journal":{"name":"Analytical Communications","volume":"13 1","pages":"333-335"},"PeriodicalIF":0.0000,"publicationDate":"1999-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Communications","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1039/A905511H","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

The possibility of using capillary isotachophoresis coupled with on-column conductivity detection for the separation of complex metal cation mixtures has been demonstrated. The simultaneous separation of a mixture of the 21 metal cations Ca2+, Mg2+, Mn2+, Co2+, Ni2+, Zn2+, Be2+, La3+, Ce3+, Pr3+, Nd3+, Sm3+, Eu3+, Gd3+, Cu2+, Y3+, Ho3+, Er3+, Tm3+, Yb3+ and Lu3+ has been reproducibly achieved using aqueous electrolytes. Calibration curves were produced for two of these ions, Co2+ and Er3+. A linear response was observed over the range from 0.02 mmol dm–3 to 1.70 mmol dm–3 for cobalt and 0.05 mmol dm–3 to 1.00 mmol dm–3 for erbium. These curves allowed limits of detection to be calculated as 0.015 mmol dm–3 for cobalt and 0.045 mmol dm–3 for erbium.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
毛细管等速电泳柱上电导率检测同时分离21种金属阳离子
利用毛细管等速电泳结合柱上电导率检测分离复杂金属阳离子混合物的可能性已经被证明。用水电解质可同时分离21种金属阳离子Ca2+、Mg2+、Mn2+、Co2+、Ni2+、Zn2+、Be2+、La3+、Ce3+、Pr3+、Nd3+、Sm3+、Eu3+、Gd3+、Cu2+、Y3+、Ho3+、Er3+、Tm3+、Yb3+和Lu3+。对其中两种离子Co2+和Er3+进行了标定。在0.02 mmol dm-3 ~ 1.70 mmol dm-3和0.05 mmol dm-3 ~ 1.00 mmol dm-3范围内观察到钴和铒的线性响应。这些曲线允许计算出钴的检出限为0.015 mmol dm-3,铒的检出限为0.045 mmol dm-3。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
A water-soluble tetrazolium salt useful for colorimetric cell viability assay Determination of α,4-dihydroxy-3-methoxybenzeneacetic acid (vanilmandelic acid) by flow injection analysis coupled with luminol–hexacyanoferrate(III) chemiluminescence detection Electrochemical detection of aluminium using single-use sensors Recent developments in the analysis of light isotopes by continuous flow isotope ratio mass spectrometry FTIR spectroscopy as detection principle in aqueous flow analysis
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1