{"title":"Effect of Longitudinal-External-Fins on Fluid Flow Characteristics for Wing-Shaped Tubes Bundle in Crossflow","authors":"Sayed Ahmed, O. Mesalhy, Mohamed A. Abdelatief","doi":"10.1155/2015/542405","DOIUrl":null,"url":null,"abstract":"A numerical study is conducted to clarify fluid-flow characteristics, pressure drop coefficient (), and the average skin friction coefficient () for wing-shaped-tubes bundle with longitudinal fins at downstream side of the tube using the commercial CFD FLUENT software package. The air-side ranges from 1800 to 9700. The tubes are employed with various fin heights () and fin thicknesses () such as 2 mm ≤ ≤ 12 mm and 1.5 mm ≤ ≤ 3.5 mm at the considered range. Results indicate that increases with for all . decreases with for all values for 1800 ≤ ≤ 4200 and then increases for 4200 ≤ ≤ 10000. Lowest values of , , and pumping power (PP) occurred at = 6 mm. Values of for = 6 mm are lower than those of NOF and = 2 mm by about 73 % and 32 %, respectively, at = 4000. decreases with . has negligible effect on . increases for 1.5 mm ≤ ≤ 2.5 mm while decreases with 2.5 mm < ≤ 3.5 mm for the considered range except for = 1850.","PeriodicalId":17290,"journal":{"name":"Journal of Thermodynamics","volume":"115 1","pages":"1-16"},"PeriodicalIF":0.0000,"publicationDate":"2015-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Thermodynamics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2015/542405","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12
Abstract
A numerical study is conducted to clarify fluid-flow characteristics, pressure drop coefficient (), and the average skin friction coefficient () for wing-shaped-tubes bundle with longitudinal fins at downstream side of the tube using the commercial CFD FLUENT software package. The air-side ranges from 1800 to 9700. The tubes are employed with various fin heights () and fin thicknesses () such as 2 mm ≤ ≤ 12 mm and 1.5 mm ≤ ≤ 3.5 mm at the considered range. Results indicate that increases with for all . decreases with for all values for 1800 ≤ ≤ 4200 and then increases for 4200 ≤ ≤ 10000. Lowest values of , , and pumping power (PP) occurred at = 6 mm. Values of for = 6 mm are lower than those of NOF and = 2 mm by about 73 % and 32 %, respectively, at = 4000. decreases with . has negligible effect on . increases for 1.5 mm ≤ ≤ 2.5 mm while decreases with 2.5 mm < ≤ 3.5 mm for the considered range except for = 1850.