Partial discharge measurements in dielectric liquids under impulse voltage

H. Yamashita
{"title":"Partial discharge measurements in dielectric liquids under impulse voltage","authors":"H. Yamashita","doi":"10.1109/14.249368","DOIUrl":null,"url":null,"abstract":"Current pulses caused by partial discharges (PDs) are measured using light-emitting diodes (LEDs) and fiber optics under impulse voltage conditions. This system has the advantage of having good isolation from the HV power supply and no effect from electromagnetic noise as compared with ordinary systems. It can detect a PD pulse having a half width of 3 ns, and has the capability of measuring PD pulse charges in the range of 1 to 2000 pC, when the optimum DC bias is applied. PD pulses and light emission or streamer formation in dielectric liquids are measured simultaneously by using an image converter camera. >","PeriodicalId":13105,"journal":{"name":"IEEE Transactions on Electrical Insulation","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1993-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"20","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Electrical Insulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/14.249368","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 20

Abstract

Current pulses caused by partial discharges (PDs) are measured using light-emitting diodes (LEDs) and fiber optics under impulse voltage conditions. This system has the advantage of having good isolation from the HV power supply and no effect from electromagnetic noise as compared with ordinary systems. It can detect a PD pulse having a half width of 3 ns, and has the capability of measuring PD pulse charges in the range of 1 to 2000 pC, when the optimum DC bias is applied. PD pulses and light emission or streamer formation in dielectric liquids are measured simultaneously by using an image converter camera. >
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
脉冲电压下介电液体的局部放电测量
在脉冲电压条件下,利用发光二极管(led)和光纤测量由局部放电(pd)引起的电流脉冲。与普通系统相比,该系统具有与高压电源隔离良好,不受电磁噪声影响的优点。它可以检测半宽3ns的PD脉冲,当施加最佳直流偏压时,具有测量1 ~ 2000pc范围内PD脉冲电荷的能力。利用图像转换相机同时测量介质液体中的PD脉冲和光发射或流光形成。>
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The effect of the definition used in measuring partial discharge inception voltages Detection and location of internal defects in the insulation of power transformers The definitions used for partial discharge phenomena The relation between thermal and electrical stress and the PD behavior of epoxy-resin transformers Digital measurement of partial discharges in full-sized power capacitors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1