Lei Gang, Lv Tianyi, Tang Jian-guo, S. Shi, Abulymit Mattuhut, Rena Turd, Jiang Wei, Xu Bingchen
{"title":"Detection of F1 antibody against Yersinia pestis in flushing fluid of heart blood of Rhombomys opimus with ELISA: a feasibility study","authors":"Lei Gang, Lv Tianyi, Tang Jian-guo, S. Shi, Abulymit Mattuhut, Rena Turd, Jiang Wei, Xu Bingchen","doi":"10.3760/CMA.J.ISSN.1000-4955.2011.01.010","DOIUrl":null,"url":null,"abstract":"Objective To analyse the feasibility of detecting F1 antibody to Yersinia pestis in flushing fluid of heart blood of Rhombomys opimus with enzyme linked immunosorbent assay(ELISA) method and its application value in surveillance of the disease. Methods Serum, flushing fluid of heart blood and infusion fluid of liver and spleen of Rhombomys opimus, which were caught by capture in the plague focus of Zunger basin in 2007, were taken to carry out detection for F1 antibodies to Yersinia pestis with ELISA method. The data were processed with SPSS 17.0. Results Positive rate and average titer of serum were 12.35%(11/162) and 25.35, of flushing fluid of heart blood were 10.49%(17/162) and 23.75 and of the infusion fluid of liver and spleen 6.79%(17/162) and 2240,respectively. No statistical difference was found in positive detection rate when it was compared between serum and flushing fluid of heart blood(χ2 = 1.333, P > 0.05), but it was obviously different between serum and infusion fluid of liver and spleen(χ2 = 7.111, P < 0.01 ) and between flushing fluid of heart blood and infusion fluid of liver and spleen(x2 = 6.250, P < 0.05). There was a significant difference in average titer between serum, flushing fluid of heart blood and infusion fluid of liver and spleen(t = 2.290, 3.612, P < 0.05 or < 0.01 ). The plague F1 antibody positive coincidence rate of serum and flushing fluid of heart blood was 85.0%(17/20), of serum and infusion fluid of liver and spleen was 55.0% (11/20), and of flushing fluid of heart blood and infusion fluid of liver and spleen was 64.7%(11/17). Conclusions The ELISA method can detect Fl antibody in flushing fluid of heart blood,and the method is feasible in plague surveillance. \n \nKey words: \nRhombmys opimus; Plague; F1 antibody; Enzyme linked immunosorbent assay","PeriodicalId":55880,"journal":{"name":"中华地方病学杂志","volume":"55 1","pages":"36-38"},"PeriodicalIF":0.0000,"publicationDate":"2011-01-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华地方病学杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.1000-4955.2011.01.010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0
Abstract
Objective To analyse the feasibility of detecting F1 antibody to Yersinia pestis in flushing fluid of heart blood of Rhombomys opimus with enzyme linked immunosorbent assay(ELISA) method and its application value in surveillance of the disease. Methods Serum, flushing fluid of heart blood and infusion fluid of liver and spleen of Rhombomys opimus, which were caught by capture in the plague focus of Zunger basin in 2007, were taken to carry out detection for F1 antibodies to Yersinia pestis with ELISA method. The data were processed with SPSS 17.0. Results Positive rate and average titer of serum were 12.35%(11/162) and 25.35, of flushing fluid of heart blood were 10.49%(17/162) and 23.75 and of the infusion fluid of liver and spleen 6.79%(17/162) and 2240,respectively. No statistical difference was found in positive detection rate when it was compared between serum and flushing fluid of heart blood(χ2 = 1.333, P > 0.05), but it was obviously different between serum and infusion fluid of liver and spleen(χ2 = 7.111, P < 0.01 ) and between flushing fluid of heart blood and infusion fluid of liver and spleen(x2 = 6.250, P < 0.05). There was a significant difference in average titer between serum, flushing fluid of heart blood and infusion fluid of liver and spleen(t = 2.290, 3.612, P < 0.05 or < 0.01 ). The plague F1 antibody positive coincidence rate of serum and flushing fluid of heart blood was 85.0%(17/20), of serum and infusion fluid of liver and spleen was 55.0% (11/20), and of flushing fluid of heart blood and infusion fluid of liver and spleen was 64.7%(11/17). Conclusions The ELISA method can detect Fl antibody in flushing fluid of heart blood,and the method is feasible in plague surveillance.
Key words:
Rhombmys opimus; Plague; F1 antibody; Enzyme linked immunosorbent assay
期刊介绍:
The Chinese Journal of Endemiology covers predominantly endemic diseases threatening health of the people in the areas affected by the diseases including Keshan disease, Kaschin-Beck Disease, iodine deficiency disorders, endemic fluorosis, endemic arsenism, plague, epidemic hemorrhagic fever, brucellosis, parasite diseases and the diseases related to local natural and socioeconomic conditions; and reports researches in the basic science, etiology, epidemiology, clinical practice, control as well as multidisciplinary studies on the diseases.