{"title":"Особенности флуоресценции паров атомов Rb, заключенных в ячейку с антирелаксационным покрытием","authors":"А. Д. Саргсян, А. В. Папоян, Д. Г. Саркисян","doi":"10.21883/os.2023.02.55016.4585-22","DOIUrl":null,"url":null,"abstract":"The features of the fluorescence spectra of Rb D1 line vapors were studied for the first time using a cell with anti-relaxation PolyDiMethylSiloxane (PDMS) coating. At high intensities (> 200mW/cm2) of a cw narrow-band diode laser in the transmission spectra due to the effect of optical pumping, there are no absorption lines at atomic transitions, while in the fluorescence spectrum, all 8 atomic transitions of the D1 line are pronounced. A strong redistribution of fluorescence intensity is registered for atomic transitions of 85Rb and 87Rb: in particular, the ratio of fluorescence amplitudes for transitions of 87Rb, Fg = 1 - Fe = 1, 2 in a regular cell is 5, while for a PDMS cell it is equal to 1.5. A physical explanation of the observed features of fluorescence in a PDMS cell is given. A significant increase of fluorescence intensity and a change in redistribution at the transitions with increasing of the PDMS cell temperature is demonstrated. It is noted that at large intensities of laser radiation (when there are no peaks on the transmission/absorption spectra of atomic transitions), fluorescence spectra remain the only convenient and informative tool for studying the behavior of atoms.","PeriodicalId":24059,"journal":{"name":"Оптика и спектроскопия","volume":"50 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Оптика и спектроскопия","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21883/os.2023.02.55016.4585-22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The features of the fluorescence spectra of Rb D1 line vapors were studied for the first time using a cell with anti-relaxation PolyDiMethylSiloxane (PDMS) coating. At high intensities (> 200mW/cm2) of a cw narrow-band diode laser in the transmission spectra due to the effect of optical pumping, there are no absorption lines at atomic transitions, while in the fluorescence spectrum, all 8 atomic transitions of the D1 line are pronounced. A strong redistribution of fluorescence intensity is registered for atomic transitions of 85Rb and 87Rb: in particular, the ratio of fluorescence amplitudes for transitions of 87Rb, Fg = 1 - Fe = 1, 2 in a regular cell is 5, while for a PDMS cell it is equal to 1.5. A physical explanation of the observed features of fluorescence in a PDMS cell is given. A significant increase of fluorescence intensity and a change in redistribution at the transitions with increasing of the PDMS cell temperature is demonstrated. It is noted that at large intensities of laser radiation (when there are no peaks on the transmission/absorption spectra of atomic transitions), fluorescence spectra remain the only convenient and informative tool for studying the behavior of atoms.