{"title":"Comparison with the influence of different types of impulse currents on the degradation of Zinc-oxide varistors","authors":"Weikang Li, X. Yao, Jinru Sun, Qingqing Li, Hao Wang, Xin Zhu","doi":"10.1109/ICHVE49031.2020.9279444","DOIUrl":null,"url":null,"abstract":"To compare different types of impulse currents on the degradation of Zinc-oxide varistors, 2 milliseconds square wave and 10/1000 microseconds impact current with the same impact energy were respectively applied to the same type of ZnO varistor samples. The three characteristic parameters' trends of samples with a diameter of 20 millimeters after multiple pulses are different, and the sample after 940 times impacts by 2 milliseconds square wave with an amplitude of 160 amperes remained intact, while the one exploded after 499 times impacts by 10/1000 microseconds impact current with an amplitude of 260 amperes. And the microstructure of samples with a diameter of 10 millimeters after the single pulse by using scanning electron microscopy (SEM) are observed. We find that with the same impact energy, the damage degree of 10/1000 microseconds impact current on ZnO varistor is relatively greater than that of 2 milliseconds square wave, which is more likely to cause the deterioration and aging of ZnO varistors.","PeriodicalId":6763,"journal":{"name":"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)","volume":"121 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVE49031.2020.9279444","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
To compare different types of impulse currents on the degradation of Zinc-oxide varistors, 2 milliseconds square wave and 10/1000 microseconds impact current with the same impact energy were respectively applied to the same type of ZnO varistor samples. The three characteristic parameters' trends of samples with a diameter of 20 millimeters after multiple pulses are different, and the sample after 940 times impacts by 2 milliseconds square wave with an amplitude of 160 amperes remained intact, while the one exploded after 499 times impacts by 10/1000 microseconds impact current with an amplitude of 260 amperes. And the microstructure of samples with a diameter of 10 millimeters after the single pulse by using scanning electron microscopy (SEM) are observed. We find that with the same impact energy, the damage degree of 10/1000 microseconds impact current on ZnO varistor is relatively greater than that of 2 milliseconds square wave, which is more likely to cause the deterioration and aging of ZnO varistors.