New parametrization method for salt permeability of reverse osmosis desalination membranes

IF 4.9 Q1 ENGINEERING, CHEMICAL Journal of Membrane Science Letters Pub Date : 2022-05-01 DOI:10.1016/j.memlet.2021.100010
P.M. Biesheuvel , J.E. Dykstra , S. Porada , M. Elimelech
{"title":"New parametrization method for salt permeability of reverse osmosis desalination membranes","authors":"P.M. Biesheuvel ,&nbsp;J.E. Dykstra ,&nbsp;S. Porada ,&nbsp;M. Elimelech","doi":"10.1016/j.memlet.2021.100010","DOIUrl":null,"url":null,"abstract":"<div><p>Reverse osmosis (RO) is the most important membrane technology for the desalination of water. Measured water and salt fluxes are traditionally analyzed in the context of the solution-diffusion (SD) model which leads to a water permeability, <em>A</em>, and a salt permeability, <em>B</em>. However, this parametrization of the salt flux is not correct for water desalination by RO membranes, because these membranes show markedly different retentions for different feed salt concentrations, a classical observation in the literature, and this effect is not captured by the SD model. Thus, the traditional salt permeability <em>B</em> is not an intrinsic property of these membranes. We present a new analysis for desalination of a 1:1 salt, which follows from a transport theory that is based on the assumption that coions are strongly excluded from the membrane, and we demonstrate that it accurately describes a large dataset of salt retention by an RO membrane as function of pressure and feed salt concentration. This analysis leads to unique values of the water and salt permeabilities, <em>A</em> and <span><math><msup><mrow><mi>B</mi></mrow><mrow><mo>″</mo></mrow></msup></math></span>, not dependent on salt concentration or permeate water flux. Because we now have an improved parametrization, we can more accurately compare different membranes or study in more detail how membrane performance depends on conditions such as salt type and temperature. The new equation can provide guidance for the design of high-performance desalination membranes and for process modeling of desalination systems.</p></div>","PeriodicalId":100805,"journal":{"name":"Journal of Membrane Science Letters","volume":"2 1","pages":"Article 100010"},"PeriodicalIF":4.9000,"publicationDate":"2022-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2772421221000106/pdfft?md5=31548e8063aad337ee297ad916b979fd&pid=1-s2.0-S2772421221000106-main.pdf","citationCount":"25","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Membrane Science Letters","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2772421221000106","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 25

Abstract

Reverse osmosis (RO) is the most important membrane technology for the desalination of water. Measured water and salt fluxes are traditionally analyzed in the context of the solution-diffusion (SD) model which leads to a water permeability, A, and a salt permeability, B. However, this parametrization of the salt flux is not correct for water desalination by RO membranes, because these membranes show markedly different retentions for different feed salt concentrations, a classical observation in the literature, and this effect is not captured by the SD model. Thus, the traditional salt permeability B is not an intrinsic property of these membranes. We present a new analysis for desalination of a 1:1 salt, which follows from a transport theory that is based on the assumption that coions are strongly excluded from the membrane, and we demonstrate that it accurately describes a large dataset of salt retention by an RO membrane as function of pressure and feed salt concentration. This analysis leads to unique values of the water and salt permeabilities, A and B, not dependent on salt concentration or permeate water flux. Because we now have an improved parametrization, we can more accurately compare different membranes or study in more detail how membrane performance depends on conditions such as salt type and temperature. The new equation can provide guidance for the design of high-performance desalination membranes and for process modeling of desalination systems.

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
反渗透脱盐膜盐透性参数化新方法
反渗透(RO)是海水淡化中最重要的膜技术。测量的水和盐通量传统上是在溶液-扩散(SD)模型的背景下分析的,该模型会得出水渗透率a和盐渗透率b。然而,盐通量的这种参数化对于反渗透膜的海水淡化是不正确的,因为这些膜在不同的饲料盐浓度下表现出明显不同的保留,这是文献中的经典观察结果,而SD模型没有捕捉到这种影响。因此,传统的盐渗透性B不是这些膜的固有特性。我们对1:1盐的脱盐进行了新的分析,该分析遵循基于离子被强烈排除在膜外的输运理论,并且我们证明它准确地描述了反渗透膜的盐保留的大数据集,作为压力和进料盐浓度的函数。这一分析得出了水和盐渗透率的独特值A和B″,不依赖于盐浓度或渗透水通量。由于我们现在有了改进的参数化技术,我们可以更准确地比较不同的膜,或者更详细地研究膜的性能如何取决于盐的类型和温度等条件。该方程可为高性能脱盐膜的设计和脱盐系统的过程建模提供指导。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
CiteScore
4.00
自引率
0.00%
发文量
0
期刊最新文献
Automated membrane characterization: In-situ monitoring of the permeate and retentate solutions using a 3D printed permeate probe device Enhanced phosphate anion flux through single-ion, reverse-selective mixed-matrix cation exchange membrane Thermodynamic efficiency of membrane separation of dilute gas: Estimation for CO2 direct air capture application The solution-diffusion model: “Rumors of my death have been exaggerated” Incorporation of polyzwitterions in superabsorbent network membranes for enhanced saltwater absorption and retention
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1