{"title":"A simple solution for boscalid selectivity issue in GC/MS analysis of apples","authors":"Darko Anđelković, Milica Branković","doi":"10.5937/savteh2301051a","DOIUrl":null,"url":null,"abstract":"Gas chromatography coupled with mass spectrometry (GC/MS) is commonly applied in pesticide residue analysis in fruit samples. Sample extracts with a high quantity of co-extractives represent a standing problem in such analysis. Co-extractives mainly affect the GC inlet and the chromatographic column performance. Waxes, identified as the main co-extractives from the apple matrix, represent a significant problem in GC/MS analysis due to low volatility and non-polarity. The purpose of this investigation was to develop and evaluate a simplified method for the analysis of boscalid in apples, with the removal of wax compounds as the main outcome. The waxes herein represented a problem not only for the performance of the instrument but directly for the determination of the boscalid since they co-eluted with the pesticide. The applied method included a combination of solvent exchange and low-temperature precipitation and resulted in complete wax removal.","PeriodicalId":7216,"journal":{"name":"Advanced Technologies","volume":"9 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Advanced Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5937/savteh2301051a","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Gas chromatography coupled with mass spectrometry (GC/MS) is commonly applied in pesticide residue analysis in fruit samples. Sample extracts with a high quantity of co-extractives represent a standing problem in such analysis. Co-extractives mainly affect the GC inlet and the chromatographic column performance. Waxes, identified as the main co-extractives from the apple matrix, represent a significant problem in GC/MS analysis due to low volatility and non-polarity. The purpose of this investigation was to develop and evaluate a simplified method for the analysis of boscalid in apples, with the removal of wax compounds as the main outcome. The waxes herein represented a problem not only for the performance of the instrument but directly for the determination of the boscalid since they co-eluted with the pesticide. The applied method included a combination of solvent exchange and low-temperature precipitation and resulted in complete wax removal.