C. W. Fink, S. Watkins, T. Aramaki, P. Brink, J. Camilleri, X. Defay, S. Ganjam, Y. Kolomensky, R. Mahapatra, N. Mirabolfathi, W. Page, R. Partridge, M. Platt, M. Pyle, B. Sadoulet, B. Serfass, S. Zuber
{"title":"Performance of a large area photon detector for rare event search applications","authors":"C. W. Fink, S. Watkins, T. Aramaki, P. Brink, J. Camilleri, X. Defay, S. Ganjam, Y. Kolomensky, R. Mahapatra, N. Mirabolfathi, W. Page, R. Partridge, M. Platt, M. Pyle, B. Sadoulet, B. Serfass, S. Zuber","doi":"10.1063/5.0032372","DOIUrl":null,"url":null,"abstract":"We present the design and characterization of a large-area Cryogenic PhotoDetector (CPD) designed for active particle identification in rare event searches, such as neutrinoless double beta decay and dark matter experiments. The detector consists of a $45.6$ $\\mathrm{cm}^2$ surface area by 1-mm-thick $10.6$ $\\mathrm{g}$ Si wafer. It is instrumented with a distributed network of Quasiparticle-trap-assisted Electrothermal feedback Transition-edge sensors (QETs) with $T_c=41.5$ $\\mathrm{mK}$ to measure athermal phonons released from interactions with photons. The detector is characterized and calibrated in the center of the detector with a collimated $^{55}$Fe X-ray source. The noise equivalent power is measured to be $1\\times 10^{-17}$ $\\mathrm{W}/\\sqrt{\\mathrm{Hz}}$ in a bandwidth of $2.7$ $\\mathrm{kHz}$. The baseline energy resolution is measured to be $\\sigma_E = 3.86 \\pm 0.04$ $(\\mathrm{stat.})^{+0.23}_{-0.00}$ $(\\mathrm{syst.})$ $\\mathrm{eV}$ (RMS). The detector also has an expected timing resolution of $\\sigma_t = 2.3$ $\\mu\\mathrm{s}$ for $5$ $\\sigma_E$ events.","PeriodicalId":8827,"journal":{"name":"arXiv: Instrumentation and Detectors","volume":"8 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-09-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"22","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"arXiv: Instrumentation and Detectors","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1063/5.0032372","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 22
Abstract
We present the design and characterization of a large-area Cryogenic PhotoDetector (CPD) designed for active particle identification in rare event searches, such as neutrinoless double beta decay and dark matter experiments. The detector consists of a $45.6$ $\mathrm{cm}^2$ surface area by 1-mm-thick $10.6$ $\mathrm{g}$ Si wafer. It is instrumented with a distributed network of Quasiparticle-trap-assisted Electrothermal feedback Transition-edge sensors (QETs) with $T_c=41.5$ $\mathrm{mK}$ to measure athermal phonons released from interactions with photons. The detector is characterized and calibrated in the center of the detector with a collimated $^{55}$Fe X-ray source. The noise equivalent power is measured to be $1\times 10^{-17}$ $\mathrm{W}/\sqrt{\mathrm{Hz}}$ in a bandwidth of $2.7$ $\mathrm{kHz}$. The baseline energy resolution is measured to be $\sigma_E = 3.86 \pm 0.04$ $(\mathrm{stat.})^{+0.23}_{-0.00}$ $(\mathrm{syst.})$ $\mathrm{eV}$ (RMS). The detector also has an expected timing resolution of $\sigma_t = 2.3$ $\mu\mathrm{s}$ for $5$ $\sigma_E$ events.