А. С. Кучерявенко, В.А. Желнов, Н.В. Черномырдин, В. Н. Курлов, К. И. Зайцев, Г.М. Катыба
{"title":"Сочетание полого сапфирового волновода и иммерсионной линзы для ТГц эндоскопии сверхвысокого разрешения","authors":"А. С. Кучерявенко, В.А. Желнов, Н.В. Черномырдин, В. Н. Курлов, К. И. Зайцев, Г.М. Катыба","doi":"10.21883/os.2023.06.55925.123-23","DOIUrl":null,"url":null,"abstract":"The development of terahertz (THz) imaging methods is hampered by the low spatial resolution of traditional diffraction-limited imaging systems, mainly due to the large wavelength of used radiation (from a few of mm to tens of µm). To solve this problem, we have proposed a new method of THz endoscopy with subwavelength spatial resolution, which is designed to study hard-to-reach areas of living organisms in vivo. A hollow-core sapphire tube with polytetrafluoroethylene outer coating is used as a waveguide, in which the antiresonant principle of radiation transmission is implemented. The waveguide and the immersion lens are optimized to provide high optical characteristics in a given wavelength range to ensure the best focusing. Two immersion lenses made of sapphire and silicon were developed and fabricated, which were then mounted on plane-parallel windows fixed on the rear end of the waveguide. The study of the field intensity distribution on the shadow side of the “waveguide–lens” system revealed a focal spot diameter of ≃0.2λ in the case of a lens made of sapphire and ≃0.3λ in the case of a lens made of crystal silicon at a wavelength λ = 500 µm, which significantly exceeds the Abbe diffraction limit. This agrees with our numerical predictions and demonstrates the promise of using the proposed endoscope for measurements with subwavelength resolution.","PeriodicalId":24059,"journal":{"name":"Оптика и спектроскопия","volume":"129 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Оптика и спектроскопия","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21883/os.2023.06.55925.123-23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The development of terahertz (THz) imaging methods is hampered by the low spatial resolution of traditional diffraction-limited imaging systems, mainly due to the large wavelength of used radiation (from a few of mm to tens of µm). To solve this problem, we have proposed a new method of THz endoscopy with subwavelength spatial resolution, which is designed to study hard-to-reach areas of living organisms in vivo. A hollow-core sapphire tube with polytetrafluoroethylene outer coating is used as a waveguide, in which the antiresonant principle of radiation transmission is implemented. The waveguide and the immersion lens are optimized to provide high optical characteristics in a given wavelength range to ensure the best focusing. Two immersion lenses made of sapphire and silicon were developed and fabricated, which were then mounted on plane-parallel windows fixed on the rear end of the waveguide. The study of the field intensity distribution on the shadow side of the “waveguide–lens” system revealed a focal spot diameter of ≃0.2λ in the case of a lens made of sapphire and ≃0.3λ in the case of a lens made of crystal silicon at a wavelength λ = 500 µm, which significantly exceeds the Abbe diffraction limit. This agrees with our numerical predictions and demonstrates the promise of using the proposed endoscope for measurements with subwavelength resolution.