A Simple and Sensitive HPLC-MS/MS Assay for the Quantitation of Blonanserin and N-Desethyl Blonanserin in Rat Plasma and Its Application to Pharmacokinetic Study
Shangxu Huang, Xiaoling Li, Zhanzhang Wang, Haoyang Lu, Tao Xiao, Xiao-jia Ni, Shu-jing Liu, Ming Zhang, D. Shang, Y. Wen
{"title":"A Simple and Sensitive HPLC-MS/MS Assay for the Quantitation of Blonanserin and N-Desethyl Blonanserin in Rat Plasma and Its Application to Pharmacokinetic Study","authors":"Shangxu Huang, Xiaoling Li, Zhanzhang Wang, Haoyang Lu, Tao Xiao, Xiao-jia Ni, Shu-jing Liu, Ming Zhang, D. Shang, Y. Wen","doi":"10.1155/2022/5914581","DOIUrl":null,"url":null,"abstract":"A high-performance liquid chromatographic method coupled with triple quadrupole mass spectrometry (LC-MS/MS) for the analysis of blonanserin and its active metabolite, N-desethyl blonanserin, in rat plasma has been developed and validated. The biological samples were treated by simple direct protein precipitation before separation on an Agilent Eclipse Plus C18 column (4.6 × 100 mm, 3.5 μm) with a column temperature of 35°C at a flow rate of 0.5 mL/min. The mobile phase A is a mixture of methanol and water (75 : 25, v/v, 5 mM ammonium formate), and the mobile phase B is acetonitrile containing 0.1% formic acid. The ratio of mobile phase A to mobile phase B is 15 : 85. Electrospray ionization (ESI) multiple reaction monitoring modes are used for detection, which are m/z 368.10 ⟶ 296.90 (blonanserin), m/z 340.15 ⟶ 297.05(N-desethyl blonanserin), and m/z 348.15⟶ 302.05 (N-desethyl blonanserin-d8). The linear response range was 0.1–100.0 ng/mL for blonanserin and N-desethyl blonanserin. The lower limit of quantification (LLOQ), calibration curves, carryover, and matrix effects were sufficiently accurate and precise according to the National Medical Products Administration (NMPA) guidelines for bioanalytical method validation. This analytical method was successfully applied in a blonanserin-poloxamer thermosensitive gel pharmacokinetic study in rats.","PeriodicalId":14974,"journal":{"name":"Journal of Analytical Methods in Chemistry","volume":"29 1","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2022-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Methods in Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1155/2022/5914581","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
A high-performance liquid chromatographic method coupled with triple quadrupole mass spectrometry (LC-MS/MS) for the analysis of blonanserin and its active metabolite, N-desethyl blonanserin, in rat plasma has been developed and validated. The biological samples were treated by simple direct protein precipitation before separation on an Agilent Eclipse Plus C18 column (4.6 × 100 mm, 3.5 μm) with a column temperature of 35°C at a flow rate of 0.5 mL/min. The mobile phase A is a mixture of methanol and water (75 : 25, v/v, 5 mM ammonium formate), and the mobile phase B is acetonitrile containing 0.1% formic acid. The ratio of mobile phase A to mobile phase B is 15 : 85. Electrospray ionization (ESI) multiple reaction monitoring modes are used for detection, which are m/z 368.10 ⟶ 296.90 (blonanserin), m/z 340.15 ⟶ 297.05(N-desethyl blonanserin), and m/z 348.15⟶ 302.05 (N-desethyl blonanserin-d8). The linear response range was 0.1–100.0 ng/mL for blonanserin and N-desethyl blonanserin. The lower limit of quantification (LLOQ), calibration curves, carryover, and matrix effects were sufficiently accurate and precise according to the National Medical Products Administration (NMPA) guidelines for bioanalytical method validation. This analytical method was successfully applied in a blonanserin-poloxamer thermosensitive gel pharmacokinetic study in rats.
期刊介绍:
Journal of Analytical Methods in Chemistry publishes papers reporting methods and instrumentation for chemical analysis, and their application to real-world problems. Articles may be either practical or theoretical.
Subject areas include (but are by no means limited to):
Separation
Spectroscopy
Mass spectrometry
Chromatography
Analytical Sample Preparation
Electrochemical analysis
Hyphenated techniques
Data processing
As well as original research, Journal of Analytical Methods in Chemistry also publishes focused review articles that examine the state of the art, identify emerging trends, and suggest future directions for developing fields.