In vitro release studies of furosemide reference tablets: influence of agitation rate, USP apparatus, and dissolution media

IF 3.4 Q2 CHEMISTRY, MEDICINAL ADMET and DMPK Pub Date : 2020-06-29 DOI:10.5599/admet.801
R. Medina-López, Sergio Guillén-Moedano, Marcela Hurtado
{"title":"In vitro release studies of furosemide reference tablets: influence of agitation rate, USP apparatus, and dissolution media","authors":"R. Medina-López, Sergio Guillén-Moedano, Marcela Hurtado","doi":"10.5599/admet.801","DOIUrl":null,"url":null,"abstract":"Furosemide is a diuretic drug widely used in chronic renal failure. The drug has low solubility and permeability, which cause clinical problems. Studying the in vitro release performance elucidates the rate and extent of drug dissolved from dosage forms under different conditions. Furosemide reference tablets were tested using USP Apparatuses 1 and 2 as well as the flow-through cell method (USP Apparatus 4), a dissolution apparatus that simulates the human gastrointestinal tract better than the other methods. Dissolution profiles were created with USP Apparatuses 1 and 2 at 25, 50, and 75 rpm and 900 mL of 0.1 M hydrochloric acid, acetate buffer (pH 4.5), and phosphate buffer (pH 6.8). USP Apparatus 4 with a laminar flow of 16 mL/min and 22.6 mm cells was used. Drug dissolution was quantified at 274 nm for 60 min. Mean dissolution time, dissolution efficiency, time to 50% dissolution, and time to 80% dissolution data were used to compare dissolution profiles. Additionally, zero-order, first-order, Higuchi, Hixson-Crowell, Makoid-Banakar, and Weibull models were used to adjust furosemide dissolution data. Between USP Apparatus 1 and 2, significant differences were observed in almost all parameters at 50 and 75 rpm (p < 0.05). A similar dissolution profile (f2 > 50) with a pharmacopoeial dissolution method (USP Apparatus 2 at 50 rpm and 900 mL of phosphate buffer pH 5.8) and USP Apparatus 4 (laminar flow of 16 mL/min, 22.6 mm cells, and pH 6.8) was observed. The Weibull function was the best mathematical model to describe the in vitro release performance of furosemide in the three USP dissolution apparatuses. These results could be used to manufacture better furosemide dosage forms and decrease the negative clinical impact of current furosemide formulations.","PeriodicalId":7259,"journal":{"name":"ADMET and DMPK","volume":"4 1","pages":"411 - 423"},"PeriodicalIF":3.4000,"publicationDate":"2020-06-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ADMET and DMPK","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5599/admet.801","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, MEDICINAL","Score":null,"Total":0}
引用次数: 8

Abstract

Furosemide is a diuretic drug widely used in chronic renal failure. The drug has low solubility and permeability, which cause clinical problems. Studying the in vitro release performance elucidates the rate and extent of drug dissolved from dosage forms under different conditions. Furosemide reference tablets were tested using USP Apparatuses 1 and 2 as well as the flow-through cell method (USP Apparatus 4), a dissolution apparatus that simulates the human gastrointestinal tract better than the other methods. Dissolution profiles were created with USP Apparatuses 1 and 2 at 25, 50, and 75 rpm and 900 mL of 0.1 M hydrochloric acid, acetate buffer (pH 4.5), and phosphate buffer (pH 6.8). USP Apparatus 4 with a laminar flow of 16 mL/min and 22.6 mm cells was used. Drug dissolution was quantified at 274 nm for 60 min. Mean dissolution time, dissolution efficiency, time to 50% dissolution, and time to 80% dissolution data were used to compare dissolution profiles. Additionally, zero-order, first-order, Higuchi, Hixson-Crowell, Makoid-Banakar, and Weibull models were used to adjust furosemide dissolution data. Between USP Apparatus 1 and 2, significant differences were observed in almost all parameters at 50 and 75 rpm (p < 0.05). A similar dissolution profile (f2 > 50) with a pharmacopoeial dissolution method (USP Apparatus 2 at 50 rpm and 900 mL of phosphate buffer pH 5.8) and USP Apparatus 4 (laminar flow of 16 mL/min, 22.6 mm cells, and pH 6.8) was observed. The Weibull function was the best mathematical model to describe the in vitro release performance of furosemide in the three USP dissolution apparatuses. These results could be used to manufacture better furosemide dosage forms and decrease the negative clinical impact of current furosemide formulations.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
速尿参比片体外释放研究:搅拌速率、USP仪器和溶出介质的影响
速尿是一种利尿剂,广泛应用于慢性肾功能衰竭。该药物溶解度和渗透性较低,引起临床问题。体外释放性能的研究阐明了不同条件下药物从剂型中溶出的速度和程度。使用USP器械1和2以及流动细胞法(USP器械4)对速尿参比片进行检测,该溶出仪比其他方法更能模拟人体胃肠道。用USP仪器1和2在25、50和75 rpm下,用900 mL 0.1 M盐酸、醋酸缓冲液(pH 4.5)和磷酸盐缓冲液(pH 6.8)创建溶解谱。采用层流16ml /min的USP仪器4和22.6 mm的细胞。用平均溶出时间、溶出效率、50%溶出时间和80%溶出时间的数据来比较药物的溶出曲线。此外,采用零阶、一阶、Higuchi、Hixson-Crowell、Makoid-Banakar和Weibull模型调整速尿溶出度数据。在USP仪器1和2之间,在50和75 rpm时几乎所有参数都有显著差异(p < 0.05)。用药典溶出法(USP Apparatus 2,转速为50 rpm, 900 mL磷酸缓冲液pH为5.8)和USP Apparatus 4(层流为16 mL/min, 22.6 mm细胞,pH为6.8)观察到相似的溶出谱(f2 > 50)。威布尔函数是描述速尿在3种USP溶出器中体外释放性能的最佳数学模型。这些结果可用于生产更好的呋塞米剂型,并减少目前呋塞米制剂的负面临床影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
ADMET and DMPK
ADMET and DMPK Multiple-
CiteScore
4.40
自引率
0.00%
发文量
22
审稿时长
4 weeks
期刊介绍: ADMET and DMPK is an open access journal devoted to the rapid dissemination of new and original scientific results in all areas of absorption, distribution, metabolism, excretion, toxicology and pharmacokinetics of drugs. ADMET and DMPK publishes the following types of contributions: - Original research papers - Feature articles - Review articles - Short communications and Notes - Letters to Editors - Book reviews The scope of the Journal involves, but is not limited to, the following areas: - physico-chemical properties of drugs and methods of their determination - drug permeabilities - drug absorption - drug-drug, drug-protein, drug-membrane and drug-DNA interactions - chemical stability and degradations of drugs - instrumental methods in ADMET - drug metablic processes - routes of administration and excretion of drug - pharmacokinetic/pharmacodynamic study - quantitative structure activity/property relationship - ADME/PK modelling - Toxicology screening - Transporter identification and study
期刊最新文献
Predicting the acute aquatic toxicity of organic UV filters used in cosmetic formulations. Determination of methotrexate using carbon paste electrode modified with ionic liquid/Ni-Co layered double hydroxide nanosheets as a voltammetric sensor. Food and bile micelle binding of zwitterionic antihistamine drugs. Molecular properties, including chameleonicity, as essential tools for designing the next generation of oral beyond rule of five drugs. Cerium oxide nanoparticles-assisted aptasensor for chronic myeloid leukaemia detection.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1