{"title":"Applied Voltage Effect in Lbl Sensors While Detecting 17α-Ethinylestradiol in Water Samples","authors":"Paulo M. Zagalo, C. Magro, P. Ribeiro, M. Raposo","doi":"10.3390/csac2021-10460","DOIUrl":null,"url":null,"abstract":"The effect of the applied voltage on impedance spectra, measured on sensors based on solid supports with interdigitated electrodes (IDE) that are either covered or not with a layer-by-layer film prepared with polyethylenimine and poly (sodium 4-styrenesulfonate), was analyzed to detect 17α-ethinylestradiol(EE2) in mineral water and tap water. The results show that the sensor response is strongly affected by the applied voltage, the presence of film, and the water matrix, meaning that electrochemical reactions develop near the IDE. However, for low values of applied voltage, the sensor response is reproducible with negligible electrochemical reactions, allowing us to conclude that 25 mV is the appropriate voltage.","PeriodicalId":9815,"journal":{"name":"Chemistry Proceedings","volume":"48 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemistry Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/csac2021-10460","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The effect of the applied voltage on impedance spectra, measured on sensors based on solid supports with interdigitated electrodes (IDE) that are either covered or not with a layer-by-layer film prepared with polyethylenimine and poly (sodium 4-styrenesulfonate), was analyzed to detect 17α-ethinylestradiol(EE2) in mineral water and tap water. The results show that the sensor response is strongly affected by the applied voltage, the presence of film, and the water matrix, meaning that electrochemical reactions develop near the IDE. However, for low values of applied voltage, the sensor response is reproducible with negligible electrochemical reactions, allowing us to conclude that 25 mV is the appropriate voltage.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Lbl传感器检测水样中17α-炔雌醇时的电压效应
本文分析了施加电压对电感阻抗谱的影响,该阻抗谱是在固体支架上测量的,固体支架上分别覆盖聚乙烯亚胺和聚4-苯乙烯磺酸钠制备的层膜或未覆盖层膜。结果表明,传感器响应受外加电压、膜的存在和水基质的强烈影响,这意味着电化学反应在IDE附近发生。然而,对于较低的施加电压值,传感器的响应是可重复的,可以忽略电化学反应,使我们得出结论,25 mV是合适的电压。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Mesoporous Silica Systems Loaded with Polyphenols Extraction of Germinated Seeds by Conventional and Modern Methods A Computational Study to Identify Some Potential Inhibitors of SARS-CoV-2 Main Protease from Biological Active Quinolones Chitosan-Based Bactericidal Interpenetrated Hydrogels Treatment of Dairy Wastewaters Using Nannochloris sp. Microalgae Strain
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1