Longterm physicochemical stability of ready-to-administer human insulin injection solutions 1 I.U./mL in 50 mL plastic syringes

F. Erdnüss, André Mohr, I. Krämer
{"title":"Longterm physicochemical stability of ready-to-administer human insulin injection solutions 1 I.U./mL in 50 mL plastic syringes","authors":"F. Erdnüss, André Mohr, I. Krämer","doi":"10.1515/pthp-2021-0014","DOIUrl":null,"url":null,"abstract":"Abstract Objectives The objective of this study was to investigate the physicochemical stability of ready-to-adminster human insulin (HI) 1 I.U./mL injection solutions of two different brand products diluted with 0.9% NaCl solution under different storage conditions either in 50 mL disposable plastic syringes or as bulk solution in infusion bags. Methods HI test solutions 1 I.U./mL were prepared with Huminsulin® Normal 100 and Actrapid® Penfill®, diluted with 0.9% sodium chloride infusion solution, and filled in Original-Perfusor® syringes or BD® Perfusion syringes. Test solutions were stored for 90 days at 2–8 °C/dark or at 20–25 °C/diffuse room light. Bulk solutions 1 I.U./mL prepared with Huminsulin® Normal 100 were stored in two different 3 L infusion bags (Ecobag® click and ExactaMix® EVA bag) at 2–8 °C/dark for five days. HI concentrations were determined by reversed-phase high-performance liquid chromatography at predefined time points. Beside regular visual inspection, subvisible particles and pH values were measured. Results Ready-to-adminster Huminsulin® Normal and Actrapid® Penfill® injection solutions 1 I.U./mL prepared in 50 mL Original-Perfusor® syringes or BD® Perfusion syringes remained physicochemically stable for up to 90 days when stored at 2–8 °C/dark and for at least 14 days when kept at 20–25 °C/diffuse room light. Prefilled 3 L polyolefin infusion bags (Ecobag® click) are suitable for the preparation of Huminsulin® 1 I.U./mL bulk solutions. In ethylene vinyl acetate (EVA) bags, HI concentrations decreased rapidly. Conclusions Ready-to-administer Huminsulin® Normal and Actrapid® Penfill® injection solutions 1 I.U./mL can be prepared in advance by dilution with 0.9% sodium chloride infusion solution and filled into 50 mL Original-Perfusor® syringes or BD® Perfusion syringes; subsequent storage at 2–8 °C/dark is possible for up to 90 days. For preparation of bulk solutions, the prefilled polyolefin infusion bag is appropriate.","PeriodicalId":19802,"journal":{"name":"Pharmaceutical Technology in Hospital Pharmacy","volume":"121 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmaceutical Technology in Hospital Pharmacy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/pthp-2021-0014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Abstract Objectives The objective of this study was to investigate the physicochemical stability of ready-to-adminster human insulin (HI) 1 I.U./mL injection solutions of two different brand products diluted with 0.9% NaCl solution under different storage conditions either in 50 mL disposable plastic syringes or as bulk solution in infusion bags. Methods HI test solutions 1 I.U./mL were prepared with Huminsulin® Normal 100 and Actrapid® Penfill®, diluted with 0.9% sodium chloride infusion solution, and filled in Original-Perfusor® syringes or BD® Perfusion syringes. Test solutions were stored for 90 days at 2–8 °C/dark or at 20–25 °C/diffuse room light. Bulk solutions 1 I.U./mL prepared with Huminsulin® Normal 100 were stored in two different 3 L infusion bags (Ecobag® click and ExactaMix® EVA bag) at 2–8 °C/dark for five days. HI concentrations were determined by reversed-phase high-performance liquid chromatography at predefined time points. Beside regular visual inspection, subvisible particles and pH values were measured. Results Ready-to-adminster Huminsulin® Normal and Actrapid® Penfill® injection solutions 1 I.U./mL prepared in 50 mL Original-Perfusor® syringes or BD® Perfusion syringes remained physicochemically stable for up to 90 days when stored at 2–8 °C/dark and for at least 14 days when kept at 20–25 °C/diffuse room light. Prefilled 3 L polyolefin infusion bags (Ecobag® click) are suitable for the preparation of Huminsulin® 1 I.U./mL bulk solutions. In ethylene vinyl acetate (EVA) bags, HI concentrations decreased rapidly. Conclusions Ready-to-administer Huminsulin® Normal and Actrapid® Penfill® injection solutions 1 I.U./mL can be prepared in advance by dilution with 0.9% sodium chloride infusion solution and filled into 50 mL Original-Perfusor® syringes or BD® Perfusion syringes; subsequent storage at 2–8 °C/dark is possible for up to 90 days. For preparation of bulk solutions, the prefilled polyolefin infusion bag is appropriate.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
50ml塑料注射器中1 iu /mL人胰岛素注射溶液的长期物理化学稳定性
摘要目的研究两种不同品牌的人胰岛素(HI) 1 iu /mL注射溶液经0.9% NaCl溶液稀释后,在50ml一次性塑料注射器和输液袋中作为散装溶液,在不同储存条件下的理化稳定性。方法用Huminsulin®Normal 100和Actrapid®Penfill®配制1 iu /mL HI试验溶液,用0.9%氯化钠输注液稀释后,分别充入Original-Perfusor®注射器或BD®Perfusion注射器。测试溶液在2-8°C/黑暗或20-25°C/漫射室内光下保存90天。用Huminsulin®Normal 100配制1 iu /mL的散装溶液,分别存放在两个不同的3 L输注袋(Ecobag®click和ExactaMix®EVA袋)中,在2-8°C/暗处保存5天。在预定时间点用反相高效液相色谱法测定HI浓度。除了定期目视检查外,还测量了不可见颗粒和pH值。1 iu /mL制备于50 mL Original-Perfusor®注射器或BD®灌注注射器中,在2-8°C/黑暗条件下保存可达90天,在20-25°C/漫射室内光条件下保存可达14天。预充3l聚烯烃输注袋(Ecobag®点击)适用于制备Huminsulin®1iu /mL散装溶液。在醋酸乙烯(EVA)袋中,HI浓度迅速下降。结论Huminsulin®Normal和Actrapid®Penfill®注射液可提前配制1 iu /mL,用0.9%氯化钠注射液稀释后充入50 mL Original-Perfusor®注射器或BD®Perfusion注射器中;随后在2-8°C/暗处储存可达90天。对于散装溶液的制备,预填充的聚烯烃输液袋是合适的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
7
审稿时长
12 weeks
期刊最新文献
Physicochemical stability of urea-containing Mitomycin C preparations in glass vials (1.0 mg/mL) and plastic syringes (2.0, 0.4, 0.2 mg/mL) Physicochemical stability of durvalumab (Imfinzi®) concentrate for solution in original vials after first opening Semi-automatic COVID-19 vaccine preparation for upscaling of vaccination: a descriptive study Assessment of the relevance of osmolality measurement as a criterion for the stability of solutions Use of a liquid chromatography-tandem mass spectrometry method to assess the concentration of epinephrine, norepinephrine, and phenylephrine stored in plastic syringes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1