Comparison of Schirmer and Tear Break Up Time (TBUT) Diagnostic Test of Dry Eye Following Phacoemulsification Cataract Surgery

Disty Andryani, Petty Purwanita, Anang Tribowo
{"title":"Comparison of Schirmer and Tear Break Up Time (TBUT) Diagnostic Test of Dry Eye Following Phacoemulsification Cataract Surgery","authors":"Disty Andryani, Petty Purwanita, Anang Tribowo","doi":"10.37275/sjo.v2i1.41","DOIUrl":null,"url":null,"abstract":"Abstract \nBackground: Phacoemulsification is a technique of modern cataract surgery with smaller corneal incision than conventional techniques but uses various effects on springs that cause dry eye syndrome (DES). DES is a multifactorial defect of tears and ocular surfaces characterized by eye discomfort. Examination of DES can be done by examining Schirmer 1 and Tear Break Up Time (TBUT). \nPurpose: To determine the accuracy, sensitivity and specificity of the Schirmer test dan TBUT in postoperative patients with phacoemulsification techniques at the Rumah Sakit Khusus Mata Province of South Sumatra. \nMethod: Diagnostic test has been done in order to the accuracy, sensitivity and specificity of the Schirmer test dan TBUT on DES in post operative cataract surgery with phacoemulsification techniques. This study has been conduct Schirmer 1 test and TBUT was done periodically from 1 week, 2 weeks and 1 month after cataract surgery. The data analysis has been done with diagnostic research by SPSS version 20.0 (SPSS, Inc Chicago, Illinois). \nResult: 40 study samples of post operative cataract surgery with phacoemulsification technique obtained by female sex with 22 out of samples were (55%), with an average age of patients between of 60-70 years.The accuracy of Shirmer 1 and TBUT test was 0,425 and the sensitivity value was 39.5% and also the specificity value was 100%. \nConclusion: Schirmer 1 test and TBUT in patients of post cataract surgery with phacoemulsification techniques are specific (100%) but less sensitive (39,5%)","PeriodicalId":22012,"journal":{"name":"Sriwijaya Journal of Ophthalmology","volume":"11 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-06-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sriwijaya Journal of Ophthalmology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37275/sjo.v2i1.41","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Background: Phacoemulsification is a technique of modern cataract surgery with smaller corneal incision than conventional techniques but uses various effects on springs that cause dry eye syndrome (DES). DES is a multifactorial defect of tears and ocular surfaces characterized by eye discomfort. Examination of DES can be done by examining Schirmer 1 and Tear Break Up Time (TBUT). Purpose: To determine the accuracy, sensitivity and specificity of the Schirmer test dan TBUT in postoperative patients with phacoemulsification techniques at the Rumah Sakit Khusus Mata Province of South Sumatra. Method: Diagnostic test has been done in order to the accuracy, sensitivity and specificity of the Schirmer test dan TBUT on DES in post operative cataract surgery with phacoemulsification techniques. This study has been conduct Schirmer 1 test and TBUT was done periodically from 1 week, 2 weeks and 1 month after cataract surgery. The data analysis has been done with diagnostic research by SPSS version 20.0 (SPSS, Inc Chicago, Illinois). Result: 40 study samples of post operative cataract surgery with phacoemulsification technique obtained by female sex with 22 out of samples were (55%), with an average age of patients between of 60-70 years.The accuracy of Shirmer 1 and TBUT test was 0,425 and the sensitivity value was 39.5% and also the specificity value was 100%. Conclusion: Schirmer 1 test and TBUT in patients of post cataract surgery with phacoemulsification techniques are specific (100%) but less sensitive (39,5%)
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
超声乳化白内障手术后干眼的Schirmer和泪液破裂时间(TBUT)诊断比较
背景:超声乳化术是一种现代白内障手术技术,其角膜切口比传统技术小,但对引起干眼综合征(DES)的弹簧有不同的影响。DES是一种多因素的泪液和眼表缺陷,以眼睛不适为特征。DES的检查可以通过检查Schirmer 1和撕裂破裂时间(TBUT)来完成。目的:探讨南苏门答腊省Rumah Sakit Khusus Mata省超声乳化术后患者Schirmer试验和TBUT的准确性、敏感性和特异性。方法:采用超声乳化术对白内障术后DES进行Schirmer试验和TBUT诊断的准确性、敏感性和特异性。本研究进行了Schirmer 1试验,并在白内障手术后1周、2周和1个月定期进行TBUT。数据分析已完成与诊断研究SPSS 20.0版(SPSS, Inc芝加哥,伊利诺伊州)。结果:40例白内障术后超声乳化技术研究样本为女性,其中22例(55%),患者平均年龄在60-70岁之间。Shirmer 1和TBUT检测的准确率为0.425,灵敏度为39.5%,特异度为100%。结论:超声乳化白内障术后患者的Schirmer - 1试验和TBUT具有特异性(100%),但敏感性较低(39.5%)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
An Investigation of Keratoplasty Procedures and Their Outcomes in Iraq Impact of COVID-19 on Preventable Blindness Detection in Bali, Indonesia Management of Wet Age-Related Macular Degeneration: A Case Report Management of Wet Age-Related Macular Degeneration: A Case Report A 39-Year-Old Woman with Oculodermal Melanocytosis: A Case Report
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1