The application of 320-slice CT " double-low" MIP imaging technique in obstructive sleep apnea syndrome with coronary heart disease

Min Xu, D. Huai, Dong-Su Yu
{"title":"The application of 320-slice CT \" double-low\" MIP imaging technique in obstructive sleep apnea syndrome with coronary heart disease","authors":"Min Xu, D. Huai, Dong-Su Yu","doi":"10.3760/CMA.J.ISSN.1008-1372.2019.12.008","DOIUrl":null,"url":null,"abstract":"Objective \nTo evaluate the value of 320-slice computed tomography (CT) \" double-low\" maximum density projection (MIP) imaging protocol (low tube voltage and low contrast agent concentration) in obstructive sleep apnea syndrome (OSAS) with coronary heart disease. \n \n \nMethods \n40 cases of OSAS with coronary heart disease in our hospital were selected. All patients underwent 320-slice CT \" double-low\" MIP imaging and received conventional coronary angiography (CAG) within 1 month. With reference to CAG examination results, the accuracy of 320-slice CT \" double low\" MIP-imaging technique in diagnosing the Obstructive sleep apnea syndrome with coronary heart disease can be evaluated. \n \n \nResults \nThe sensitivity, specificity, accuracy, positive predictive value and negative predictive value of 320-slice CT\" double-low \" MIP imaging in the diagnosis of obstructive respiratory sleep disorder with coronary disease were 95.14%, 94.43%, 95.33%, 83.62%, 98.20%. respectively. The heart rate of testers was (65.20±4.79)bpm/min, the dose length product (DLP) was (98.22±32.54)mGy·cm, and the effective radiation dose (ED) was (1.35±0.42)mSv. \n \n \nConclusions \nCompared with CAG, the 320-slice CT \" double-low\" MIP imaging technique reduced doses of radiation while maintained the good quality of image. Therefore, this technique has high application value as a clinical diagnosis method to diagnose patients with obstructive respiratory sleep disorder and coronary heart disease. \n \n \nKey words: \nSleep apnea, obstructive; Coronary disease; Tomography, X-ray computed","PeriodicalId":15276,"journal":{"name":"中国医师杂志","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-12-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中国医师杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.1008-1372.2019.12.008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective To evaluate the value of 320-slice computed tomography (CT) " double-low" maximum density projection (MIP) imaging protocol (low tube voltage and low contrast agent concentration) in obstructive sleep apnea syndrome (OSAS) with coronary heart disease. Methods 40 cases of OSAS with coronary heart disease in our hospital were selected. All patients underwent 320-slice CT " double-low" MIP imaging and received conventional coronary angiography (CAG) within 1 month. With reference to CAG examination results, the accuracy of 320-slice CT " double low" MIP-imaging technique in diagnosing the Obstructive sleep apnea syndrome with coronary heart disease can be evaluated. Results The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of 320-slice CT" double-low " MIP imaging in the diagnosis of obstructive respiratory sleep disorder with coronary disease were 95.14%, 94.43%, 95.33%, 83.62%, 98.20%. respectively. The heart rate of testers was (65.20±4.79)bpm/min, the dose length product (DLP) was (98.22±32.54)mGy·cm, and the effective radiation dose (ED) was (1.35±0.42)mSv. Conclusions Compared with CAG, the 320-slice CT " double-low" MIP imaging technique reduced doses of radiation while maintained the good quality of image. Therefore, this technique has high application value as a clinical diagnosis method to diagnose patients with obstructive respiratory sleep disorder and coronary heart disease. Key words: Sleep apnea, obstructive; Coronary disease; Tomography, X-ray computed
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
320层CT“双低”MIP成像技术在阻塞性睡眠呼吸暂停综合征合并冠心病中的应用
目的评价320层计算机断层扫描(CT)的临床应用价值。阻塞性睡眠呼吸暂停综合征(OSAS)合并冠心病的“双低”最大密度投影(MIP)成像方案(低管电压和低造影剂浓度)。方法选取我院收治的OSAS合并冠心病患者40例。所有患者均在1个月内行320层CT“双低”MIP成像,并行常规冠状动脉造影(CAG)。结合CAG检查结果,评价320层CT“双低”mip成像技术诊断阻塞性睡眠呼吸暂停综合征合并冠心病的准确性。结果320层CT“双低”MIP成像诊断阻塞性呼吸睡眠障碍合并冠心病的敏感性、特异性、准确性、阳性预测值和阴性预测值分别为95.14%、94.43%、95.33%、83.62%、98.20%。分别。受试者心率为(65.20±4.79)bpm/min,剂量长度积(DLP)为(98.22±32.54)mGy·cm,有效辐射剂量(ED)为(1.35±0.42)mSv。结论与CAG相比,320层CT“双低”MIP成像技术在保持良好图像质量的同时减少了辐射剂量。因此,该技术作为诊断阻塞性呼吸睡眠障碍和冠心病患者的临床诊断方法具有很高的应用价值。关键词:睡眠呼吸暂停;阻塞性;冠状动脉疾病;x线计算机断层扫描
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
中国医师杂志
中国医师杂志 Medicine-Medicine (all)
CiteScore
0.10
自引率
0.00%
发文量
20937
期刊介绍:
期刊最新文献
Effect of sivelestat sodium on early inflammatory reaction and pulmonary edema in rats with smoke inhalation induced lung injury Effect of CEA on neurological function and coagulation function in patients with ischemic stroke Intraoperative real-time imaging-guided laparoscopic liver resection Application progress of laparoscopy in the treatment of liver tumors Analysis of risk of endobronchial biopsy-induced bleeding in different locations of lung cancer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1