Determination of Ascorbic Acid Based on a Platinum Nanoparticles Modified Au Electrode

J. He, Qiang Xu, Z. Song, Hainan Kuang
{"title":"Determination of Ascorbic Acid Based on a Platinum Nanoparticles Modified Au Electrode","authors":"J. He, Qiang Xu, Z. Song, Hainan Kuang","doi":"10.4028/www.scientific.net/AMM.110-116.1732","DOIUrl":null,"url":null,"abstract":"A Platinum nanoparticles modified Au electrode has been successfully fabricated by using an in situ growth method. In this method, the Platinum nanoparticles could be grown on the Au electrode surface via the one-step immersion into the mixture of H2PtCl6 (analytical grade, 1g/L), NaBH4 (analytical grade) and polyvinylpyrrolidone K30 (PVP, analytical grade). A certain amount of PVP was added into the reaction system to prevent the coagulation of the Platinum nanoparticles, which obtained by the chemical redox reaction of H2PtCl6 and NaBH4. The structures and morphologies of the Platinum nanoparticles were characterized by transmission electron microscopy (TEM) and scanning electron microscopy (SEM) . The direct electrochemical behavior of ascorbic acid in 0.3 mol/L NaCl medium at the Platinum nanoparticles modified electrode has been investigated in detail. Compared to a bare Au electrode, a substantial decrease in the overvoltage of the ascorbic acid was observed at the Platinum nanoparticles modified electrode with oxidation starting at ca. 0.20 V vs. SCE (saturated KCl). At an applied potential of 0.18V, this modified electrode produced high and reproducible sensitivity to ascorbic acid and linear responses were obtained over a concentration range from 0.600 to 3.267 μmol/L with a detection limit of 1.9 nmol/L(S/N=3). The fabrication method of this sensor, which has highly sensitive, low working potential, and fast amperometric sensing to ascorbic acid, is simple and without using complex equipment. In addition, the sensor has been successfully used to detect ascorbic acid in real sample, thus is promising for the future development of ascorbic acid sensors.","PeriodicalId":8039,"journal":{"name":"Applied Mechanics and Materials","volume":"460 1","pages":"1732 - 1735"},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Mechanics and Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4028/www.scientific.net/AMM.110-116.1732","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

A Platinum nanoparticles modified Au electrode has been successfully fabricated by using an in situ growth method. In this method, the Platinum nanoparticles could be grown on the Au electrode surface via the one-step immersion into the mixture of H2PtCl6 (analytical grade, 1g/L), NaBH4 (analytical grade) and polyvinylpyrrolidone K30 (PVP, analytical grade). A certain amount of PVP was added into the reaction system to prevent the coagulation of the Platinum nanoparticles, which obtained by the chemical redox reaction of H2PtCl6 and NaBH4. The structures and morphologies of the Platinum nanoparticles were characterized by transmission electron microscopy (TEM) and scanning electron microscopy (SEM) . The direct electrochemical behavior of ascorbic acid in 0.3 mol/L NaCl medium at the Platinum nanoparticles modified electrode has been investigated in detail. Compared to a bare Au electrode, a substantial decrease in the overvoltage of the ascorbic acid was observed at the Platinum nanoparticles modified electrode with oxidation starting at ca. 0.20 V vs. SCE (saturated KCl). At an applied potential of 0.18V, this modified electrode produced high and reproducible sensitivity to ascorbic acid and linear responses were obtained over a concentration range from 0.600 to 3.267 μmol/L with a detection limit of 1.9 nmol/L(S/N=3). The fabrication method of this sensor, which has highly sensitive, low working potential, and fast amperometric sensing to ascorbic acid, is simple and without using complex equipment. In addition, the sensor has been successfully used to detect ascorbic acid in real sample, thus is promising for the future development of ascorbic acid sensors.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
铂纳米粒子修饰金电极测定抗坏血酸
采用原位生长法制备了铂纳米粒子修饰的金电极。该方法采用H2PtCl6(分析级,1g/L)、NaBH4(分析级)和聚乙烯吡罗烷酮K30(分析级,PVP)的混合物,一步浸出铂纳米颗粒,在Au电极表面生长。在反应体系中加入一定量的PVP,防止H2PtCl6与NaBH4化学氧化还原反应得到的铂纳米粒子的混凝。利用透射电子显微镜(TEM)和扫描电子显微镜(SEM)对纳米铂的结构和形貌进行了表征。研究了抗坏血酸在0.3 mol/L NaCl介质中在铂纳米粒子修饰电极上的直接电化学行为。与裸金电极相比,在铂纳米粒子修饰的电极上观察到抗坏血酸的过电压显著降低,与SCE(饱和KCl)相比,氧化开始于约0.20 V。在0.18V电压下,该电极对抗坏血酸具有较高的灵敏度和重复性,在0.600 ~ 3.267 μmol/L浓度范围内呈线性响应,检出限为1.9 nmol/L(S/N=3)。该传感器的制作方法简单,不需要复杂的设备,具有高灵敏度、低工作电位和抗坏血酸快速安培传感的特点。此外,该传感器已成功用于实际样品中的抗坏血酸检测,为抗坏血酸传感器的未来发展提供了良好的前景。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analysis and Design of Steel Cement Storage Silo Study on Influence of Core Structure on Catalytic Converter Performance Using CFD Structural and Geochemistry of Air Piau Gold Mineralisation in Kelantan, North-East Peninsular Malaysia A Novel Powder Addition Method for Improving Tensile Strength of Polylactic-Acid Prepared by Using Fused Filament Fabrication (FFF) Monitoring of Building Services Using Artificial Intelligence
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1