Breakdown characteristics of He gas at cryogenic temperature and low pressure

M. Irmisch, A. Ulbricht, V. Zwecker, R. Badent, A. Hinderer, J. Olbrisch, M. Jaarah
{"title":"Breakdown characteristics of He gas at cryogenic temperature and low pressure","authors":"M. Irmisch, A. Ulbricht, V. Zwecker, R. Badent, A. Hinderer, J. Olbrisch, M. Jaarah","doi":"10.1109/14.231533","DOIUrl":null,"url":null,"abstract":"The breakdown of He between plane electrodes was investigated under conditions similar to those of the operation of superconducting magnets at room temperature and 4 K. It was found that the breakdown voltage in the Paschen minimum was higher than expected at room temperature, which was explained by the presence of impurity. An additional effect observed, especially at low pressures, is that the measured pressure in the vacuum vessel does not seem to agree with the pressure of the electrode gap. Furthermore a helium leak of 1 Pa 1/s was introduced between the electrodes. No measurable influence of this leak was found within the measuring accuracy at low temperatures. >","PeriodicalId":13105,"journal":{"name":"IEEE Transactions on Electrical Insulation","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1993-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Electrical Insulation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/14.231533","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

The breakdown of He between plane electrodes was investigated under conditions similar to those of the operation of superconducting magnets at room temperature and 4 K. It was found that the breakdown voltage in the Paschen minimum was higher than expected at room temperature, which was explained by the presence of impurity. An additional effect observed, especially at low pressures, is that the measured pressure in the vacuum vessel does not seem to agree with the pressure of the electrode gap. Furthermore a helium leak of 1 Pa 1/s was introduced between the electrodes. No measurable influence of this leak was found within the measuring accuracy at low temperatures. >
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
低温低压下He气体的击穿特性
在类似于超导磁体在室温和4k下工作的条件下,研究了He在平面电极间的击穿。发现在室温下,Paschen最小击穿电压高于预期值,这是由于杂质的存在造成的。观察到的另一个效应,特别是在低压下,是真空容器中测量的压力似乎与电极间隙的压力不一致。此外,在电极之间引入了1 pa1 /s的氦泄漏。在低温下的测量精度范围内未发现该泄漏的可测量影响。>
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The effect of the definition used in measuring partial discharge inception voltages Detection and location of internal defects in the insulation of power transformers The definitions used for partial discharge phenomena The relation between thermal and electrical stress and the PD behavior of epoxy-resin transformers Digital measurement of partial discharges in full-sized power capacitors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1