DESIGN OF COMPOSITE SKIN PANEL FOR ROOF IN ACCORDANCE WITH THE REQUIREMENTS OF EN 1995-1-1 AND GSN В.1.2-2:2006

S. Pichugin, Sergiy Shkirenko, M. Pents
{"title":"DESIGN OF COMPOSITE SKIN PANEL FOR ROOF IN ACCORDANCE WITH THE REQUIREMENTS OF EN 1995-1-1 AND GSN В.1.2-2:2006","authors":"S. Pichugin, Sergiy Shkirenko, M. Pents","doi":"10.26906/znp.2019.53.1887","DOIUrl":null,"url":null,"abstract":"In the article design of composite (timber and plywood) skin panel has been considered according European and nationalstandards. The panel consists of timber webs and plywood skin. The design parameters are depth of webs and distance between webs within the defined skin parameters. In design the method of fictitious cross-section is applied. Check of the ultimate limit states is conducted in accordance with EN 1995-1-1 (ДБН В.2.6-161:2017). Loads to the panel are determined according to ДБН В.1.2.-2:2006. The usage of European and national standards complies with the actual requirements andwiden methodological base.","PeriodicalId":32910,"journal":{"name":"Zbirnik naukovikh prats'' Seriia Galuzeve mashinobuduvannia budivnitstvo","volume":"15 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zbirnik naukovikh prats'' Seriia Galuzeve mashinobuduvannia budivnitstvo","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26906/znp.2019.53.1887","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In the article design of composite (timber and plywood) skin panel has been considered according European and nationalstandards. The panel consists of timber webs and plywood skin. The design parameters are depth of webs and distance between webs within the defined skin parameters. In design the method of fictitious cross-section is applied. Check of the ultimate limit states is conducted in accordance with EN 1995-1-1 (ДБН В.2.6-161:2017). Loads to the panel are determined according to ДБН В.1.2.-2:2006. The usage of European and national standards complies with the actual requirements andwiden methodological base.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
按照en1995-1-1和GSN В.1.2-2:2006的要求设计屋面复合蒙皮板
本文根据欧洲和国家标准对复合材料(木材和胶合板)蒙皮板的设计进行了考虑。面板由木材网和胶合板表皮组成。设计参数是在定义的蒙皮参数内腹板的深度和腹板之间的距离。在设计中采用了虚拟截面法。根据EN 1995-1-1 (ДБН В.2.6-161:2017)对极限状态进行检查。面板上的负载根据ДБН В.1.2.-2:2006确定。欧洲和国家标准的使用符合实际要求,并扩大了方法基础。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
24 weeks
期刊最新文献
TRAY RESEARCH OF THE STRAIN STATE OF SOIL BASES REINFORCED BY SOIL-CEMENT ELEMENTS UNDER THE STRIP STAMP THE EXPERIMENTAL RESEARCHES OF REINFORCED CONCRETE I-BEAM ELEMENTS WITH NORMAL CRACKS WHEN TURNING THE STUDY OF PROFITABILITY OF DWELLING RECONSTRUCTION OF FIRST MASS SERIES STRENGTH ANALYSIS OF GLUED-IN STEEL RODS WITH DIFFERENT LOCATIONS IN CLT PANELS CROSS SECTION COMPARATIVE ANALYSIS OF DESIGN SOLUTIONS OF METAL SILOS
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1