Effect of Nanofilled Resin-Based Coating on the Compressive Strength of Glass Ionomer Cement – in vitro

Ardy Setiawan, Juanita A. Gunawan, Selviana Wulansari, Didi Nugroho
{"title":"Effect of Nanofilled Resin-Based Coating on the Compressive Strength of Glass Ionomer Cement – in vitro","authors":"Ardy Setiawan, Juanita A. Gunawan, Selviana Wulansari, Didi Nugroho","doi":"10.22146/majkedgiind.65512","DOIUrl":null,"url":null,"abstract":"Glass ionomer cement as one of the restoration materials requires high compressive strength so it can last during functional activity. The latest glass ionomer cement comes with glass hybrid technology and a nanofilled resin-based protective coating which is said to increase the compressive strength of glass ionomer cement. The aim of this study was to analyze the effect of nanofilled resin-based coating and the types of glass ionomer cement materials on their compressive strength. Two types of commercial glass ionomer cement material were used; conventional (Fuji IX GP Extra), and hybrid (EQUIA Forte Fill) glass ionomer cement. Forty cylindrical (4 x 6 mm) samples were prepared in each group. The main group was divided into 4 subgroups (n=10) based on the protective coating used (EQUIA Forte Coat, Varnish, Control, Water + EQUIA Forte Coat). Eight subgroups were immersed in 37 °C distilled water for 7 days, then a compressive strength test was performed using a universal testing machine. The data analysis showed no significant difference in the compressive strength between the two types of glass ionomer cement materials (p>0.05). The use of a protective coating was associated with a significant decrease in the compressive strength (p<0.05). The use of glass ionomer cement without the application of a protective coating was considered to be quite good because the compressive strength value of the restoration still met the standards of the American Dental Association.","PeriodicalId":31262,"journal":{"name":"Majalah Kedokteran Gigi Indonesia","volume":"59 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Majalah Kedokteran Gigi Indonesia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22146/majkedgiind.65512","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Glass ionomer cement as one of the restoration materials requires high compressive strength so it can last during functional activity. The latest glass ionomer cement comes with glass hybrid technology and a nanofilled resin-based protective coating which is said to increase the compressive strength of glass ionomer cement. The aim of this study was to analyze the effect of nanofilled resin-based coating and the types of glass ionomer cement materials on their compressive strength. Two types of commercial glass ionomer cement material were used; conventional (Fuji IX GP Extra), and hybrid (EQUIA Forte Fill) glass ionomer cement. Forty cylindrical (4 x 6 mm) samples were prepared in each group. The main group was divided into 4 subgroups (n=10) based on the protective coating used (EQUIA Forte Coat, Varnish, Control, Water + EQUIA Forte Coat). Eight subgroups were immersed in 37 °C distilled water for 7 days, then a compressive strength test was performed using a universal testing machine. The data analysis showed no significant difference in the compressive strength between the two types of glass ionomer cement materials (p>0.05). The use of a protective coating was associated with a significant decrease in the compressive strength (p<0.05). The use of glass ionomer cement without the application of a protective coating was considered to be quite good because the compressive strength value of the restoration still met the standards of the American Dental Association.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
纳米填充树脂基涂层对玻璃离聚体水泥抗压强度的影响
玻璃离子水门合剂作为一种修复材料,要求具有较高的抗压强度,以保证其在功能活动中持续存在。最新的玻璃离子水泥采用了玻璃混合技术和纳米填充树脂基保护涂层,据说可以提高玻璃离子水泥的抗压强度。本研究的目的是分析纳米填充树脂基涂层和玻璃离子水泥材料的类型对其抗压强度的影响。采用了两种商用玻璃离子水泥材料;常规(Fuji IX GP Extra)和混合(EQUIA Forte Fill)玻璃离子水泥。每组制备40个圆柱形(4 × 6 mm)样品。根据使用的保护涂层(EQUIA Forte Coat, Varnish, Control, Water + EQUIA Forte Coat)将主组分为4个亚组(n=10)。8个亚组在37℃蒸馏水中浸泡7天,然后使用万能试验机进行抗压强度试验。数据分析显示,两种玻璃离子水门汀材料抗压强度差异无统计学意义(p < 0.05)。防护涂层的使用与抗压强度的显著降低相关(p<0.05)。使用玻璃离聚体水泥而不使用保护涂层被认为是相当好的,因为修复的抗压强度值仍然符合美国牙科协会的标准。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
20 weeks
期刊最新文献
Prevalence and identification of oral candida species in patients with type 2 diabetes in Yogyakarta An Inhibition effect of immersion in effervescent garlic ethanol extract (Allium sativum L.) against Staphylococcus aureus growth on heat cured acrylic Complex aestheticss treatment of six maxillary anterior teeth with smile design and deep bite correction In vitro evaluation of coenzyme Q10 on primary fibroblast culture A potential of Jasminum sambac (L.) Aiton leaf nano-extract as spray treatment of gingivitis-induced Sprague Dawley rats
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1