N. Watanabe, J. Levri, V. Peng, S. Scharf, M. Diaz-Abad
{"title":"Average volume-assured pressure support for patients with obstructive sleep apnea with failed CPAP titration","authors":"N. Watanabe, J. Levri, V. Peng, S. Scharf, M. Diaz-Abad","doi":"10.5935/1984-0063.20210015","DOIUrl":null,"url":null,"abstract":"ABSTRACT Objectives: Obstructive sleep apnea (OSA) is a common disease, often treated using continuous positive airway pressure (CPAP) therapy. In many cases, patients fail a CPAP titration study due to inadequate control of the apnea-hypopnea index (AHI, events/hour) or due to treatment-emergent central sleep apnea (TE-CSA). We report our experience using a mode of non-invasive ventilation for alternative treatment of these patients. Material and Methods: We reviewed records of adults who had OSA with AHI≥15 diagnosed on polysomnography (PSG) with failed CPAP titration and in whom titrations with average volume-assured pressure support (AVAPS) with auto-titrating expiratory positive airway pressure were performed. Results: Forty-five patients, age 57.9±13.1 y, 26 males, body mass index (BMI) 40.2±8.7kg/m 2 . Reasons for CPAP titration failure included: TE-CSA (25, 55.6%) and inadequate control of AHI at maximum CPAP of 20cm H2O (20, 44.4%). Changes noted from baseline PSG to AVAPS titration: AHI: 65.3±29.3 decreased to 22.3±16.1 (p<0.001). Median time SpO2 ≤88%: 63.7 to 6.9min (p<0.001). In 16 patients the AHI was reduced to <15 and in 16 additional patients the AHI was reduced to <30. Improvement in AHI was not related to gender, age, or opioid use, but was correlated with BMI: ∆AHI=12.2 - (1.4 * BMI); p=0.05. AVAPS resulted in improved sleep architecture: median N3 sleep increased: 1.4% to 19.6% total sleep time (TST) (p<0.001), and median R sleep increased: 6.4% to 13.6% TST (p<0.01). Discussion: For patients with OSA for whom CPAP titration failed, titration with AVAPS may be an effective treatment.","PeriodicalId":21848,"journal":{"name":"Sleep Science","volume":"70 1","pages":"328 - 332"},"PeriodicalIF":1.0000,"publicationDate":"2021-01-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sleep Science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5935/1984-0063.20210015","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 3
Abstract
ABSTRACT Objectives: Obstructive sleep apnea (OSA) is a common disease, often treated using continuous positive airway pressure (CPAP) therapy. In many cases, patients fail a CPAP titration study due to inadequate control of the apnea-hypopnea index (AHI, events/hour) or due to treatment-emergent central sleep apnea (TE-CSA). We report our experience using a mode of non-invasive ventilation for alternative treatment of these patients. Material and Methods: We reviewed records of adults who had OSA with AHI≥15 diagnosed on polysomnography (PSG) with failed CPAP titration and in whom titrations with average volume-assured pressure support (AVAPS) with auto-titrating expiratory positive airway pressure were performed. Results: Forty-five patients, age 57.9±13.1 y, 26 males, body mass index (BMI) 40.2±8.7kg/m 2 . Reasons for CPAP titration failure included: TE-CSA (25, 55.6%) and inadequate control of AHI at maximum CPAP of 20cm H2O (20, 44.4%). Changes noted from baseline PSG to AVAPS titration: AHI: 65.3±29.3 decreased to 22.3±16.1 (p<0.001). Median time SpO2 ≤88%: 63.7 to 6.9min (p<0.001). In 16 patients the AHI was reduced to <15 and in 16 additional patients the AHI was reduced to <30. Improvement in AHI was not related to gender, age, or opioid use, but was correlated with BMI: ∆AHI=12.2 - (1.4 * BMI); p=0.05. AVAPS resulted in improved sleep architecture: median N3 sleep increased: 1.4% to 19.6% total sleep time (TST) (p<0.001), and median R sleep increased: 6.4% to 13.6% TST (p<0.01). Discussion: For patients with OSA for whom CPAP titration failed, titration with AVAPS may be an effective treatment.