Approaches for Measuring Fast Modulation of Optical Properties Induced by 511keV Photon Interactions

Diana Jeong, Li Tao, Zander Adams, Yushin Kim, C. Levin
{"title":"Approaches for Measuring Fast Modulation of Optical Properties Induced by 511keV Photon Interactions","authors":"Diana Jeong, Li Tao, Zander Adams, Yushin Kim, C. Levin","doi":"10.1109/NSS/MIC42677.2020.9508093","DOIUrl":null,"url":null,"abstract":"With a goal to achieve less than 10 picosecond (ps) coincidence time resolution for advancing time-of-flight positron emission tomography (TOF-PET), we seek to leverage the effects of transient free carriers generated from 511 keV interactions in a material. Most ultrafast optics methods rely on many excitation particles with a priori information on their arrival times. However, in PET it is critical to find a way to sensitively detect single, randomly emitted 511 keV annihilation photons from the ionization it produces. We investigate two ways to increase the signal: employing probe laser wavelength in the mid-IR and confining the probe beam to match the size of ionization tracks created by the 511 keV photons. We observed a continued decrease of 2% in transmission of the mid-IR probe beam (8μm) in a 10 X 10 X 1 mm3 Cadmium Telluride crystal with 511 keV annihilation irradiation over 300 seconds. The trend was reversed when the radiation source is removed, and reached the previous baseline transmission in 800 seconds. For confining the interaction volume to match the probe beam diameter, we revised a previously investigated interferometry approach to use a focused beam and did not apply a bias voltage across the detector crystal. With a 405nm laser diode as an excitation source, a shift of 43% in transmitted signal voltage was observed, and with Am-241 alpha source irradiation, a 1% shift was measured. With the improved sensitivity, these findings provide insights into possible methods of detecting single 511 keV events.","PeriodicalId":6760,"journal":{"name":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","volume":"402 1","pages":"1-3"},"PeriodicalIF":0.0000,"publicationDate":"2020-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSS/MIC42677.2020.9508093","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

With a goal to achieve less than 10 picosecond (ps) coincidence time resolution for advancing time-of-flight positron emission tomography (TOF-PET), we seek to leverage the effects of transient free carriers generated from 511 keV interactions in a material. Most ultrafast optics methods rely on many excitation particles with a priori information on their arrival times. However, in PET it is critical to find a way to sensitively detect single, randomly emitted 511 keV annihilation photons from the ionization it produces. We investigate two ways to increase the signal: employing probe laser wavelength in the mid-IR and confining the probe beam to match the size of ionization tracks created by the 511 keV photons. We observed a continued decrease of 2% in transmission of the mid-IR probe beam (8μm) in a 10 X 10 X 1 mm3 Cadmium Telluride crystal with 511 keV annihilation irradiation over 300 seconds. The trend was reversed when the radiation source is removed, and reached the previous baseline transmission in 800 seconds. For confining the interaction volume to match the probe beam diameter, we revised a previously investigated interferometry approach to use a focused beam and did not apply a bias voltage across the detector crystal. With a 405nm laser diode as an excitation source, a shift of 43% in transmitted signal voltage was observed, and with Am-241 alpha source irradiation, a 1% shift was measured. With the improved sensitivity, these findings provide insights into possible methods of detecting single 511 keV events.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
511keV光子相互作用诱导的光学特性快速调制测量方法
为了实现小于10皮秒(ps)的符合时间分辨率,以推进飞行时间正电子发射断层扫描(TOF-PET),我们试图利用材料中511 keV相互作用产生的瞬态自由载流子的影响。大多数超快光学方法依赖于许多具有其到达时间先验信息的激发粒子。然而,在PET中,找到一种方法来灵敏地探测它产生的电离中随机发射的511 keV湮灭光子是至关重要的。我们研究了两种增加信号的方法:采用中红外探测激光波长和限制探测光束以匹配511 keV光子产生的电离轨迹的大小。我们观察到在511 keV湮灭辐照300秒后,中红外探测光束(8μm)在10 X 10 X 1 mm3碲化镉晶体中的透射率持续下降2%。当辐射源被移除后,这一趋势发生了逆转,在800秒内达到了之前的基线传输。为了限制相互作用体积以匹配探测光束直径,我们修改了先前研究的干涉测量方法,使用聚焦光束,并且不在探测器晶体上施加偏置电压。以405nm激光二极管作为激发源,观察到传输信号电压偏移43%,在Am-241 α源照射下,测量到传输信号电压偏移1%。随着灵敏度的提高,这些发现为检测单个511 keV事件的可能方法提供了见解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Performance of Dual-Ended Readout PET Detectors Based on SiPMs with Different Microcell Sizes Neural Network-based Inter-crystal Scatter Event Positioning in a PET System Design Based on 3D Position Sensitive Detectors An e-LINAC driven PGNAA system for concealed drug inspection Design of a Multi-Technology Pre-Clinical SPECT System Comprehensive Simulation and Design of 3D Silicon Sensors for Enhanced Timing Performance
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1