Effectiveness Enhancement of the Double Tube Heat Exchanger Using ZnO Nanofluid

H. Kadhim
{"title":"Effectiveness Enhancement of the Double Tube Heat Exchanger Using ZnO Nanofluid","authors":"H. Kadhim","doi":"10.52716/jprs.v12i2.660","DOIUrl":null,"url":null,"abstract":"In this study, the effect of adding zinc oxide nanoparticles to the reversible effect double tube heat exchanger with a length of 1.5 meters, an outer diameter of 19.0 mm, is made of copper material that is used by Nano water as a cold liquid. Zinc solid nanoparticles with a volume concentration of 3% were used with water as the base liquid. The cold nanoscale water flows into the real tube with a volume of 4 L/min which enters into the heat exchanger at 16°C, where the hot water flows into the separator of the heat exchanger representing a blank volume of 6 L/min. The Reynolds number range and flowrate ranges are 10000 to 20000 and 5 to 15 respectively. The heat exchanger was introduced at a temperature of 65°C. An improvement in the performance of the exchanger was shown in the case of using water with the addition of nanoparticles","PeriodicalId":16710,"journal":{"name":"Journal of Petroleum Research and Studies","volume":"94 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Petroleum Research and Studies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52716/jprs.v12i2.660","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

In this study, the effect of adding zinc oxide nanoparticles to the reversible effect double tube heat exchanger with a length of 1.5 meters, an outer diameter of 19.0 mm, is made of copper material that is used by Nano water as a cold liquid. Zinc solid nanoparticles with a volume concentration of 3% were used with water as the base liquid. The cold nanoscale water flows into the real tube with a volume of 4 L/min which enters into the heat exchanger at 16°C, where the hot water flows into the separator of the heat exchanger representing a blank volume of 6 L/min. The Reynolds number range and flowrate ranges are 10000 to 20000 and 5 to 15 respectively. The heat exchanger was introduced at a temperature of 65°C. An improvement in the performance of the exchanger was shown in the case of using water with the addition of nanoparticles
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
ZnO纳米流体增强双管换热器效能
在本研究中,将氧化锌纳米颗粒添加到长度为1.5米,外径为19.0 mm的可逆效应双管换热器中,该换热器由纳米水作为冷液使用的铜材料制成。采用体积浓度为3%的锌固体纳米颗粒,以水为基液。冷纳米级水以4l /min的体积流入实管,实管在16℃时进入热交换器,其中热水以6l /min的空白体积流入热交换器分离器。雷诺数范围为10000 ~ 20000,流量范围为5 ~ 15。在65℃的温度下引入热交换器。在加入纳米粒子的情况下,交换器的性能得到了改善
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Iraq Crude Oil Exports- July, August, September, October, November, December/ 2022 Biosynthesis of Fe/Pd Bimetallic Nanoparticles and Used for Removal of Synthetic Oily Wastewater A Regional Static Model of the Dammam Aquifer as a Source of Injection Water, Southern Iraq Effect of the Deep Marin Balambo Formation on the Qamchuqa Reservoirs in Jambur Field Converting of Waste Crude Oil of East Baghdad Oil Field into Light Hydrocarbons Using Thermal Cracking Technology
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1