{"title":"EUS-Guided Portal Pressure Gradient Measurement in Patients with Portal Hypertension: Evidence-Based Case Report","authors":"Putra Nur Hidayat, Juferdy Kurniawan","doi":"10.24871/2332022254-258","DOIUrl":null,"url":null,"abstract":"Aim: This evidence-based case report aims to assess the accuracy of EUS-PPG measurement in patients with portal hypertension.Method: A literature search was performed using PubMed, Cochrane, ProQuest, and EBSCO. A total of 2 articles were selected after meeting the inclusion and exclusion criteria. Critical study assessment was conducted to assess the validity, importance, and applicability of the study.Results: As a result, the first study found higher EUS-PPG measurement values in patients with clinical parameters of portal hypertension and the second study found a good correlation between EUS-PPG measurement values with hepatic vein pressure gradient (HVPG) and transjugular intrahepatic portosystemic shunt (TIPS) portal pressure gradient (PPG).Conclusion: From these two studies, it can be concluded that EUS-PPG measurement is a safe, effective, and feasible method to be performed on patients.","PeriodicalId":22564,"journal":{"name":"The Indonesian Journal of Gastroenterology, Hepatology and Digestive Endoscopy","volume":"6 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-12-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Indonesian Journal of Gastroenterology, Hepatology and Digestive Endoscopy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24871/2332022254-258","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Aim: This evidence-based case report aims to assess the accuracy of EUS-PPG measurement in patients with portal hypertension.Method: A literature search was performed using PubMed, Cochrane, ProQuest, and EBSCO. A total of 2 articles were selected after meeting the inclusion and exclusion criteria. Critical study assessment was conducted to assess the validity, importance, and applicability of the study.Results: As a result, the first study found higher EUS-PPG measurement values in patients with clinical parameters of portal hypertension and the second study found a good correlation between EUS-PPG measurement values with hepatic vein pressure gradient (HVPG) and transjugular intrahepatic portosystemic shunt (TIPS) portal pressure gradient (PPG).Conclusion: From these two studies, it can be concluded that EUS-PPG measurement is a safe, effective, and feasible method to be performed on patients.