Distributed Generation integration with enhanced power system protection

Ramini Hareesh, C. Pramod
{"title":"Distributed Generation integration with enhanced power system protection","authors":"Ramini Hareesh, C. Pramod","doi":"10.1109/TAPENERGY.2015.7229637","DOIUrl":null,"url":null,"abstract":"Distributed Generation (DG) has increased tremendously from last two decades because of its advantages like production of highly reliable power by utilizing the renewable resources. But due to the integration of DG, power quality issues and power system protection problems arise. Fuse Recloser miscoordination is one of the problem which occurs due to the integration of DG with the grid. This paper presents a control with which fuse recloser coordination will not fail and loadis shared between the DGs according to their rating. To validate the same, simulations have been done in MATLAB/Simulink. Load sharing between the DGs has been simulated with the help of fuzzy controller for more precise control.","PeriodicalId":6552,"journal":{"name":"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)","volume":"34 1","pages":"310-315"},"PeriodicalIF":0.0000,"publicationDate":"2015-06-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Technological Advancements in Power and Energy (TAP Energy)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TAPENERGY.2015.7229637","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

Distributed Generation (DG) has increased tremendously from last two decades because of its advantages like production of highly reliable power by utilizing the renewable resources. But due to the integration of DG, power quality issues and power system protection problems arise. Fuse Recloser miscoordination is one of the problem which occurs due to the integration of DG with the grid. This paper presents a control with which fuse recloser coordination will not fail and loadis shared between the DGs according to their rating. To validate the same, simulations have been done in MATLAB/Simulink. Load sharing between the DGs has been simulated with the help of fuzzy controller for more precise control.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
分布式发电集成,增强电力系统保护
分布式发电(DG)由于其利用可再生资源生产高可靠性电力等优点,在过去的二十年中得到了极大的发展。但是由于DG的一体化,产生了电能质量问题和电力系统保护问题。熔断器重合闸失配是DG与电网一体化过程中出现的问题之一。本文提出了一种控制方法,该方法可以使熔断器协调不失效,并使负载在各断路器之间按额定值分担。为了验证这一点,在MATLAB/Simulink中进行了仿真。利用模糊控制器对各dg之间的负载分担进行了仿真,实现了更精确的控制。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Reduction of common mode voltage in three phase inverter A novel topology of forward-flyback PFC converter with constant on-time control Online benefit optimization in a liberalized/free microgrid market model UHVDC transmission with dedicated metallic return Bridgeless flyback converter for low power lighting application
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1