Instrumentation of a portable EMG sensor in a single PCB for human motion pattern detection

A. Narayan, H. Dasgupta, Himangshu Pal
{"title":"Instrumentation of a portable EMG sensor in a single PCB for human motion pattern detection","authors":"A. Narayan, H. Dasgupta, Himangshu Pal","doi":"10.1109/ISPTS.2015.7220069","DOIUrl":null,"url":null,"abstract":"The objective of this work is to make a Surface Electromyography (EMG) signal detection sensor to test and analyze human motion pattern. EMG signal has a very small amplitude level and a frequency range of 20 Hz to 200 Hz. In order to realize the sensor, a circuit and its single layer PCB has been designed to amplify and filter the differential potential between Ag/AgCl electrodes at different points. After that the signal has been stored in computer using NI ELVIS II (DAQ) and LABVIEW at a sampling rate of 1000Hz. Then the signal has been used to calculate the stride length of a particular foot by a single threshold comparison method. The ultimate result shows that the calculated and actual stride length matches in 89% of the cases.","PeriodicalId":6520,"journal":{"name":"2015 2nd International Symposium on Physics and Technology of Sensors (ISPTS)","volume":"41 1","pages":"1-5"},"PeriodicalIF":0.0000,"publicationDate":"2015-03-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 2nd International Symposium on Physics and Technology of Sensors (ISPTS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISPTS.2015.7220069","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

The objective of this work is to make a Surface Electromyography (EMG) signal detection sensor to test and analyze human motion pattern. EMG signal has a very small amplitude level and a frequency range of 20 Hz to 200 Hz. In order to realize the sensor, a circuit and its single layer PCB has been designed to amplify and filter the differential potential between Ag/AgCl electrodes at different points. After that the signal has been stored in computer using NI ELVIS II (DAQ) and LABVIEW at a sampling rate of 1000Hz. Then the signal has been used to calculate the stride length of a particular foot by a single threshold comparison method. The ultimate result shows that the calculated and actual stride length matches in 89% of the cases.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
用于人体运动模式检测的单个PCB中的便携式肌电传感器仪器
本工作的目的是制造一种表面肌电信号检测传感器来测试和分析人体的运动模式。肌电图信号的幅度非常小,频率范围为20 ~ 200 Hz。为了实现该传感器,设计了一个电路及其单层PCB来放大和滤波不同位置Ag/AgCl电极之间的差分电位。然后用NI ELVIS II (DAQ)和LABVIEW以1000Hz的采样率将信号存储在计算机中。然后用单阈值比较法计算某只脚的步长。最终结果表明,计算出的步幅和实际步幅在89%的情况下是匹配的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Development of machine vision based system for classification of Guava fruits on the basis of CIE1931 chromaticity coordinates IT02. TiO2 nanoparticles loaded on graphene/carbon composite nanofibers by electrospinning for increased photocatalysis High temperature operable low humidity (10 to 20%RH) sensor using spin coated SnO2 thin films Design and simulation of blocked blood vessel for early detection of heart diseases Novel techniques for mapping infectious diseases using point of care diagnostic sensors
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1